OPERATING YOUR WATER HEATER

OPERATING YOUR WATER HEATER

Lighting Instructions

Read and understand these directions thoroughly before attempting to light or re-light the pilot. Make sure the viewport is not missing or damaged. (See Figure 23) Make sure the tank is completely filled with water before lighting the pilot. Check the data plate near the gas control valve/thermostat for the correct gas. Do not use this water heater with any gas other than the one listed on the data plate. If you have any questions or doubts, consult your gas supplier or gas utility company.

Lighting InstructionsWARNING

Explosion Hazard

Replace viewport if glass is missing or damaged.

Failure to do so can result in death, explosion or fire.

Robertshaw Gas Valve - Lighting Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which is lighted by a piezoelectric igniter. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

ϖDo not try to light any appliance.

ϖDo not touch any electrical switch; do not use any phone in your building.

ϖImmediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

ϖIf you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or move by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance. Water heaters subjected to flood conditions or anytime the gas controls, main burner or pilot have been submerged in water require replacement of the entire water heater.

E.DO NOT USE THIS APPLIANCE IF THERE HAS BEEN AN IGNITION OF VAPORS. Immediately call a qualified service technician to inspect the appliance. Water heaters subjected to a flammable vapors ignition will show a discoloration on the air intake grid and require replacement of the entire water heater.

LIGHTING INSTRUCTIONS

1.STOP! It is imperative that you read all the safety warnings before lighting the pilot.

2.Remove the outer door.

3.Turn the temperature dial counterclockwise Robertshaw Gas Valve - Lighting Instructions to its lowest setting.

 

 

 

RESET

130° F

 

 

 

 

 

 

 

120° F

 

 

 

BUTTON

BAR

 

 

 

 

 

 

 

BAR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL

 

 

 

 

WA

 

 

 

 

 

 

KNOB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

DIAL

 

AUTIO

 

 

M

 

 

 

 

 

 

 

 

 

 

READUNITROL

STOP

T

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

 

 

 

 

 

ALL

 

 

 

 

 

 

 

 

 

 

 

BEFOREWARNING

INDEX

 

 

 

 

 

 

 

 

 

 

 

 

INSTRUCTIONS

W

H

R

 

 

 

 

 

 

T

 

LIGHTING

BARS

T

A

SES

 

Y

 

V

H

 

 

H

T

 

O TTE

R

 

 

 

WA

 

E

E

 

A

JU

 

 

A

 

 

 

R

R INCRE

 

 

 

C

 

 

R

 

 

IS

 

 

 

IN

 

 

 

7.Depress the reset button all the way in and IMMEDIATELY depress the igniter button until you hear a loud click. Observe the pilot through the view port. Do not release the reset button. Repeat immediately if pilot does not light on the first try. If the pilot does not light by the fourth attempt with the igniter, repeat steps 4 - 7. Continue to hold the button for about (1) minute after the pilot is lit. Release the reset button and it will pop back up. Pilot should remain lit. If the pilot light goes out, repeat steps 3 - 7.

PUSHBUTTON

IGNITER

C

M

 

K OF SCALD

 

A

AUTIO

 

 

 

N

 

 

130° F

T

 

 

 

OI

 

 

 

 

N

 

 

 

V

BAR

 

 

 

 

CA

 

 

 

O I

TA

 

 

 

 

 

 

 

 

4. Depress the dial stop and turn

 

N O

CAUTION

gas control knob clockwise

O

DAMAGE

 

P

 

DO NOT PRY

 

 

ON DIAL

 

I

 

 

 

L

 

 

to the “OFF” position.

T

OFF

WILL

 

RESULT

5.To clear any gas that may have FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS accumulated wait ten (10) minutes.

If you then smell gas, STOP! Follow “B” in the safety warning above. If you do not smell gas go to the next step.

 

 

 

CAUTION

 

 

 

DO NOT PRY

 

O

F

ON DIAL

6. Turn the gas control knob

F

DAMAGE

N

PILOT

 

 

 

O

WILL

 

 

 

RESULT

counterclockwise

 

 

 

to “PILOT”.

 

 

 

IMPORTANT: If the pilot will not stay lit after several tries, depress the dial stop and turn gas control knob to “OFF”, then call your service technician or gas supplier.

IMPORTANT: If the reset button (see graphic at step 3) does not pop up when released, stop and immediately shut off the gas at the line valve or tank. Call your service technician or gas supplier.

8.Turn the gas control knob counterclockwise TO TURN OFF GAS TO APPLIANCE

to “ON”.

T

ON DIAL

 

FFO

CAUTION

 

 

DO NOT PRY

 

O

DAMAGE

 

L

9. Set the temperature dial to

I

WILL

O N

 

 

P

RESULT

the desired setting.

 

 

10. Replace the outer door.

TO TURN OFF GAS TO APPLIANCE

1. Turn the temperature dial counterclockwise

to its

2. Turn the gas control knob clockwise

to the “OFF”

lowest setting.

 

position.

 

17

Image 17
Contents Ultra Low Nox Gas Water Heater Installation Instructions and Use & Care Guidewith the Flame Lock Safety System Table Of Contents WATER HEATER SAFETYImportant Instructions PAGEImportant Information About This Water Heater INSTALLING YOUR GAS WATER HEATERConsumer Information Consumer ResponsibilitiesSite Location Location RequirementsState of California Clearances and AccessibilityGas Pressure Gas SupplyGas Requirements Combustion Air Supply and Ventilation All Air from Inside the Building Unconfined SpaceConfined Space Louvers and Grilles All Air from OutdoorsOpening ReferenceVent Connectors Draft hood InstallationVent Pipe System Vent Pipe SizeVertical Exhaust Gas Vent Chimney ConnectionPiping Installation Water System PipingClosed System/Thermal Expansion Explosion Hazard Temperature and Pressure Relief ValveDo not plug valve. Do not remove valve T&P Relief Valve and Pipe Insulation Some ModelsCombination Space Heating/Potable Water System Solar InstallationSpecial Applications Important Information About This Water Heater Installation ChecklistWater Heater Location Combustion Air Supply and VentilationLighting Instructions OPERATING YOUR WATER HEATERFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE LIGHTING Checking the DraftLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCEStacking Burner FlamesEmergency Shut Down Water Temperature RegulationSafety Shut-off Operational ConditionsCondensation Water Heater SoundsRoutine Preventive Maintenance MAINTENANCE OF YOUR WATER HEATERDraining and Flushing Temperature and Pressure Relief ValveRemoving the Burner Door Assembly Replacement PartsReplacing the Pilot Assembly Natural Gas Burner Ultra Low NoxExternal Inspection & Cleaning of the Flame-trap Cleaning the Pilot AssemblyCleaning the Combustion Chamber and Flame-trap Replacing the ThermocouplePiezoelectric Igniter System Replacing the Burner Door AssemblyTesting the Igniter System Flame LockSafety System Operational Checklist TROUBLESHOOTING CHARTPOSSIBLE CAUSES PROBLEMCORRECTIVE ACTION PILOT WILL NOT REMAIN LITSection A Pilot light will not light PILOT LIGHT TROUBLESHOOTING CHARTRepair Parts List REPAIR PARTS ILLUSTRATIONListed Parts Kits and Illustrations