Whirlpool BFG1F5040T3PV 7K, BFG1F5050T4NOV, BFG1H4040S3NOV Combustion Air Supply and Ventilation

Page 7

Combustion Air Supply and Ventilation

WARNING

Carbon Monoxide Warning Follow all the local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1 (NFPA 54)- latest edition to properly install vent system.

Failure to do so can result in death, explosion, or carbon monoxide poisoning.

IMPORTANT: Air for combustion and ventilation must not come from a corrosive atmosphere. Any failure due to corrosive elements in the atmosphere is excluded from warranty coverage.

The following types of installation (not limited to the following) will require outdoor air for combustion due to chemical exposure and may reduce but not eliminate the presence of corrosive chemicals in the air:

beauty shops

photo processing labs

buildings with indoor pools

water heaters installed in laundry, hobby, or craft rooms

water heaters installed near chemical storage areas

Combustion air must be free of acid-forming chemicals such as sulfur, fluorine, and chlorine. These elements are found in aerosol sprays, detergents, bleaches, cleaning solvents, air fresheners, paint, and varnish removers, refrigerants, and many other commercial and household products. When burned, vapors from these products form highly corrosive acid compounds. These products should not be stored or used near the water heater or air inlet.

Combustion and ventilation air requirements are determined by the location of the water heater. The water heater may be located in either an open (unconfined) area or in a confined area or small enclosure such as a closet or small room. Confined spaces are areas with less than 50 cubic feet for each 1,000 BTUH of the total input for all gas- using appliances.

7

Image 7
Contents Installation Instructions Use & Care Guide Table Of Contents Water Heater SafetyUnpacking the Water Heater Installing Your GAS Water HeaterImportant Information About This Water Heater Consumer InformationSite Location Location RequirementsClearances and Accessibility Gas Requirements Gas SupplyGas Pressure Combustion Air Supply and Ventilation Confined Space Unconfined SpaceAll Air from Inside the Building Louvers and Grilles All Air from OutdoorsVent Pipe Size Drafthood InstallationVent Connectors Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Relief Valve and Pipe Insulation Some Models Temperature and Pressure Relief ValveSpecial Applications Solar InstallationCombination Space Heating/Potable Water System Installation Checklist Lighting Instructions Operating Your Water HeaterChecking the Draft Water Temperature RegulationOperational Conditions Routine Preventive Maintenance Maintenance of Your Water HeaterDraining and Flushing Natural Gas Burner Low Nox Replacement PartsRemoving the Manifold Assembly Removing the Burner from the Manifold AssemblyCleaning the Combustion Chamber and Flame-trap External Inspection & Cleaning of the Flame-trapReplacing the Thermocouple Testing the Igniter System Replacing the Manifold AssemblyPiezoelectric Igniter System Removing and Replacing the Gas Control Valve/Thermostat Flame Lock Safety System Operational ChecklistSlow HOT Water Pilot Light Troubleshooting Flowchart Repair Parts List Repair Parts IllustrationListed Parts Kits and Illustrations

192906, BFG1F4034T3PV, BFG1F4034T3PV 7K, 195102, 211456 specifications

The Whirlpool BFG2H4040T3NOV E and BFG1J4040T3NOV 5K are high-efficiency gas water heaters that cater to the needs of modern households with their cutting-edge technologies and features. Engineered with the latest advancements, these models ensure optimal performance, energy efficiency, and user convenience.

One of the standout features of the Whirlpool BFG series is its robust build quality. Both models are designed with a cylindrical stainless-steel tank that enhances durability and longevity. The insulation used in these heaters minimizes heat loss, ensuring that water remains hot for an extended period while reducing energy consumption. This characteristic not only saves on utility bills but also contributes to environmentally friendly practices.

Additionally, the BFG2H4040T3NOV E and BFG1J4040T3NOV 5K incorporate smart technology that simplifies the user experience. The thermostatic control allows homeowners to set and maintain precise water temperatures according to their preferences, providing comfort and convenience. Furthermore, these models are equipped with a high-efficiency burner system that maximizes the heating process, ensuring that hot water is readily available when needed.

Safety is a significant focus of Whirlpool's design philosophy. The BFG series features advanced safety mechanisms including a flame arrestor that prevents combustion incidents, along with a built-in pressure relief valve. These safety features offer peace of mind for users, ensuring worry-free operation in everyday use.

Moreover, the Whirlpool BFG model line is designed with installation flexibility in mind. They can be seamlessly integrated into various home designs, whether residential or commercial. The compact nature of these heaters allows for space-saving installations while delivering high output efficiency.

The BFG series also emphasizes user serviceability with clear instructions for maintenance and troubleshooting, enabling homeowners to address common issues effectively without requiring professional assistance. This aspect further enhances the overall ownership experience, making these water heaters an excellent choice for energy-conscious consumers.

In summary, the Whirlpool BFG2H4040T3NOV E and BFG1J4040T3NOV 5K stand out in the market due to their exceptional durability, advanced technology, safety features, and ease of installation. With their energy-efficient design and user-friendly functionality, these gas water heaters provide the perfect solution for families seeking reliable hot water solutions.