Whirlpool BFG2F4040T3NOV 7K, BFG1F5050T4NOV, BFG1H4040S3NOV, BFG1F5040T3PV Installation Checklist

Page 16

Important Information About This Water Heater

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes.

Questions? Call 1-877-817-6750.

Installation Checklist

Water Heater Location

Water heater location is important and can affect system performance. Please check the following:

Installation area free of corrosive elements and flammable materials.

Centrally located with the water piping system. Located as close to the gas piping and vent pipe system as possible.

Located indoors and in a vertical position. Protected from freezing temperatures.

Proper clearances from combustible surfaces maintained and not installed directly on a carpeted floor.

Provisions made to protect the area from water damage. Drain pan installed and piped to an adequate drain.

Sufficient room to service the water heater. See Clearances and Accessibility section of this manual.

Water heater not located near an air moving device.

Is the installed environment dirty (excessive amounts of lint, dirt, dust, etc.)? If so, the flame arrestor located on the bottom of the water heater will need to be cleaned periodically. Refer to the Maintenance of your Water Heater section of this manual for information on cleaning the flame-trap.

Fresh air supply free of corrosive elements and flammable vapors.

Fresh air openings sized correctly with consideration given to the blocking effect of louvers and grilles.

Ductwork is the same cross-sectional area as the openings.

Vent Pipe System

Check for proper drafting at the water heater draft hood. Refer to the “Checking the Draft” section of this manual for the test procedure. If the procedure shows insufficient draft is present, please check the following.

Drafthood properly installed.

Vent connectors securely fastened with screws and supported properly to maintain six inch clearance.

Vent connector made of approved material and sized correctly.

Vent pipe system installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-latest edition.

Flue baffle engaged in slots provided in the flue tube.

Check the vent system for restrictions/obstructions and check the vent termination height. Refer to the Air Supply and Ventilation section of this water heater manual for specific requirements.

Recheck for sufficient combustion air supply.

Combustion Air Supply and Ventilation

Check for sufficient combustion air supply. Insufficient air for the combustion of gas will result in the flame becoming “lazy”, thereby allowing heat to build up in the combustion chamber. This excessive heat will cause a thermal switch on the door assembly to trip. Is the water heater installed in a closet or other small, enclosed space? If so:

Are there openings for make-up air to enter and exit the room/area?

Are the openings of sufficient size? Remember, if there are other gas-fired or air-consuming appliances in the same room, you need more make-up air. Refer to the Location Requirements section of this water heater manual for specific requirements.

Fresh air not taken from areas that contain negative pressure producing devices such as exhaust fans, fireplaces, etc.

Is there a furnace/air handler in the same room space as the water heater? If so, has a return air duct system been attached that exits the room? If so, check for leaks on the air duct system. If no air duct system is present, correct immediately by contacting a local Heating, Ventilation, Air- Conditioning & Refrigeration (HVAC-R) authorized service provider.

Water System Piping

Temperature and pressure relief valve properly installed with a discharge line run to an open drain and protected from freezing.

All piping properly installed and free of leaks.

Heater completely filled with water.

Closed system pressure build-up devices installed.

Tempering valve (when applicable) installed per manufacturer’s instructions (See Water Temperature Regulation section).

Gas Supply and Piping

Gas type is the same as that listed on the water heater data plate.

Gas line equipped with shut-off valve, union, and drip leg.

Approved pipe joint compound used.

Adequate pipe size and approved pipe material.

An approved noncorrosive leak detection solution used to check all connections and fittings for possible gas leaks. Correct any leak found.

16

Image 16
Contents Installation Instructions Use & Care Guide Water Heater Safety Table Of ContentsInstalling Your GAS Water Heater Important Information About This Water HeaterConsumer Information Unpacking the Water HeaterLocation Requirements Site LocationClearances and Accessibility Gas Requirements Gas SupplyGas Pressure Combustion Air Supply and Ventilation Confined Space Unconfined SpaceAll Air from Inside the Building All Air from Outdoors Louvers and GrillesDrafthood Installation Vent ConnectorsVent Pipe System Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingClosed System/Thermal Expansion Temperature and Pressure Relief Valve Relief Valve and Pipe Insulation Some ModelsSpecial Applications Solar InstallationCombination Space Heating/Potable Water System Installation Checklist Operating Your Water Heater Lighting InstructionsWater Temperature Regulation Checking the DraftOperational Conditions Routine Preventive Maintenance Maintenance of Your Water HeaterDraining and Flushing Replacement Parts Removing the Manifold AssemblyRemoving the Burner from the Manifold Assembly Natural Gas Burner Low NoxCleaning the Combustion Chamber and Flame-trap External Inspection & Cleaning of the Flame-trapReplacing the Thermocouple Testing the Igniter System Replacing the Manifold AssemblyPiezoelectric Igniter System Flame Lock Safety System Operational Checklist Removing and Replacing the Gas Control Valve/ThermostatSlow HOT Water Pilot Light Troubleshooting Flowchart Repair Parts Illustration Repair Parts ListListed Parts Kits and Illustrations

192906, BFG1F4034T3PV, BFG1F4034T3PV 7K, 195102, 211456 specifications

The Whirlpool BFG2H4040T3NOV E and BFG1J4040T3NOV 5K are high-efficiency gas water heaters that cater to the needs of modern households with their cutting-edge technologies and features. Engineered with the latest advancements, these models ensure optimal performance, energy efficiency, and user convenience.

One of the standout features of the Whirlpool BFG series is its robust build quality. Both models are designed with a cylindrical stainless-steel tank that enhances durability and longevity. The insulation used in these heaters minimizes heat loss, ensuring that water remains hot for an extended period while reducing energy consumption. This characteristic not only saves on utility bills but also contributes to environmentally friendly practices.

Additionally, the BFG2H4040T3NOV E and BFG1J4040T3NOV 5K incorporate smart technology that simplifies the user experience. The thermostatic control allows homeowners to set and maintain precise water temperatures according to their preferences, providing comfort and convenience. Furthermore, these models are equipped with a high-efficiency burner system that maximizes the heating process, ensuring that hot water is readily available when needed.

Safety is a significant focus of Whirlpool's design philosophy. The BFG series features advanced safety mechanisms including a flame arrestor that prevents combustion incidents, along with a built-in pressure relief valve. These safety features offer peace of mind for users, ensuring worry-free operation in everyday use.

Moreover, the Whirlpool BFG model line is designed with installation flexibility in mind. They can be seamlessly integrated into various home designs, whether residential or commercial. The compact nature of these heaters allows for space-saving installations while delivering high output efficiency.

The BFG series also emphasizes user serviceability with clear instructions for maintenance and troubleshooting, enabling homeowners to address common issues effectively without requiring professional assistance. This aspect further enhances the overall ownership experience, making these water heaters an excellent choice for energy-conscious consumers.

In summary, the Whirlpool BFG2H4040T3NOV E and BFG1J4040T3NOV 5K stand out in the market due to their exceptional durability, advanced technology, safety features, and ease of installation. With their energy-efficient design and user-friendly functionality, these gas water heaters provide the perfect solution for families seeking reliable hot water solutions.