Whirlpool TA07002F0 manual 126.5~max, ~ampratingor less, Separatecircuit

Page 16

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

If codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate.

Checkwith a qualifiedelectricianif youarenot suretheair conditioneris properlygrounded.

model and serial label

model and serial label

Athree-wire,single-phase,60.HZ,hC-only, electricalsupplyis requiredon a separate circuit, A 15-amptime-delayfuseor circuit breakeris required.Copperwire (#I4 gauge) is required.Thefusesizemustnot exceedthe circuit ratingspecifiedon themodelandserial label.

Themodelandserialkibefis locatedon theleft sidepanel,or behindthefront panelabovethe coil area.

Recommended grounding method

Foryour personalsafety,this air,conditioner mustbegrounded.This air conditioneris equippedwith a powersupplvcord havinga 3- prong groundingplug. To minimizepossible shockhazard,thecord mustbepluggedinto a mating,3-pronggrounding-typewall receptacle, groundedin accordancewith all local codes andordinances.If a matingwall receptacleis not available,it is the customer’sresponsibility to havea properly grounded,i-prong wdu receptacleinstalledby a licensedinstaller.

It is thecustomer’sresponsibility:

. To contacta qualified efectricafinstaller.

lTo ‘assurethattheelectricalinstallationis adequateandin conformancewith National ElectricalCode,ANSVNFPA70 - latest edition*, *andaUlocal codesandordinances.

Copies of IIE standards bed may be oblained from * National Fire Prolect~on hsocrdlion

~k~dl Park

Quincy, MassaclmseNs OL260

Specificelectricalrequirementsarelistedin the chart. Followtherequirementsfor the typeof plug on thepowersupplycord.

Plug Type

115~volt- 103.5~min.,

7.5~ampratingor less-

a doubleoutletis

7.6-through 12-ampratings- use only a singleoutlet anda

typewall receptacle

126.5~max.

acceptable.

separatecircuit.

Image 16
Contents Use&CareGuide Contents Safety Your safety Is important To usAir It is your responsibility toOperating Instructions Starting your air conditionerUsing the Energy Saver settings Using the exhaust controlChanging air direction Cleaning the front panel Cleaning the air filterAir filter tips For models with built-in filters see figurePerformina Annual Maintenanvce On nextRepairing paint damage Normal operating soundsTroubleshooting Your air conditioner will not operate hUnit blows fuses or trips circuit breakers Air conditionerUnit turns on and off too much, or does not cool room Water drips from cabinet into your houseRequesting Assistance or Service Ordering accessoriesWarranty Sealed refrigerationTable of Contents Thelocation shouldprovide Important Observe all governing codesFree movement of air to roomsto be cooled Tools needed ~ampratingor less 126.5~maxSeparatecircuit Goto Page5 for installationsteps Goto Page4 for installationstepsFollowtheinstructionsfor your typeof air conditioner Thesame.Whentheair conditioneris centered Cut foamblocksMounting hole Filler boardCurtain AlternateholePushI L Cabinetuntil panelsnapsm place