Bacharach 2072-0400 manual Operating Notes

Page 4

MAC2000

SERIES: MAC2000

Refrigerant: 134a

KENT MOORE: J-055000

 

Air Conditioning and Refrigerant

Service Solution

WARNING

PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. OVERFILLING OF THE TANK MAY CAUSE VIOLENT EXPLOSION AND POSSIBLE INJURY OR DEATH. Safety devices require the use of only authorized refillable tanks. Refer to the instruction manual for tank specifications and ordering information. Do not recover refrigerants in a non-refillable storage container! Regulations require refrigerant to be transported only in specifically authorized containers.

ALL HOSES MAY CONTAIN LIQUID REFRIGERANT UNDER PRESSURE. Contact with refrigerant may cause injury. Wear proper protective equipment, including safety goggles. Disconnect hoses with extreme caution.

HIGH VOLTAGE ELECTRICITY INSIDE PANELS. RISK OF ELECTRICAL SHOCK. Disconnect power before service unit. Refer to the instruction manual.

TO REDUCE RISK OF FIRE, avoid the use of an extension cord. The extension cord may overheat. If you must use an extension cord, the cord must be 14 AWG minimum and as short as possible. Do not use this equipment in the vicinity of spilled or open containers of gasoline or other flammable substances.

Use this equipment in locations with mechanical ventilation that provides at least four air changes per hour or locate the equipment at least 18 inches above the floor.

Make certain that all safety devices are functioning properly before operating the unit. Before operating, read and follow the instructions and warnings in the manual.

CAUTION: SHOULD BE OPERATED BY QUALIFIED PERSONNEL. Technician must be familiar with air conditioning and refrigeration systems, refrigerants and the dangers of pressurized components.

Use with the R-134a refrigerant only. This equipment is not designed for any other purpose other than recovering, recycling and charging refrigerants. Do not mix refrigerant types.

OPERATING NOTES

Change the filter-drier when the display shows Change Filter message. Follow the instructions for the changeover. At temperatures exceeding 120 °F / °C, wait 10 minutes between recovery jobs.

R-134a WARNINGS!

Use the MAC2000 unit only with R-134a refrigerants. Cross-contamination with other refrigerant types will cause severe damage to the A/C systems and to service tools and equipment. Do not mix refrigerant types through a system or in the same container.

Avoid breathing A/C refrigerant and lubricant vapor mist. Exposure may irritate eyes, nose and throat. To remove R-134a from the system, use service equipment certified to meet the requirements of SAE-J2210 (R-134a recycling equipment). If accidental system discharge occurs, ventilate work area before resuming service.

HFC-134a service equipment or vehicle A/C systems should not be pressured tested or leak tested with compressed air. Some mixtures of air/HFC-134a have been shown to be combustible at elevated pressures. These mixtures are potentially dangerous and may result in fire or explosion causing injury or property damage.

Additional health and safety information may be obtained from refrigerant and lubricant manufacturers.

ii

Instruction 2072-0400

Image 4
Contents Instruction Register Your Warranty by Visiting Table of Contents Operating Notes Introduction Glossary of Terms General Operating GuidelinesComponent Location and Description MAC2000 Control PanelMAC2000 Front View MAC2000 Right-Side View MAC2000 Left-Side View MAC2000 Back View Introduction MAC2000 Using the Function Keys Introduction MAC2000 Initial Set-Up Initial Set-Up InstructionsInitial Set-Up MAC2000 External Source Tank Testing Checking Vehicles for Possible Contaminated SystemsInitial Set-Up MAC2000 Operation MAC2000 Operational OverviewRecovery Vacuum Charge Snapshot Next Diagnosing A/C System Operation Using the Snap-Shot Mode Tank air Data ChangeSnap-Shot Transmitter Main Capture Reset Recover Menu Print Recovery Mode Vacuum Mode Evacuation Charge Mode Instruction System Flush Mode Oil Flush Instruction Refrigerant Management System Internal Tank Manual Refill System Set Up Identify RefrigerantCheck Internal Tank for Air Operation MAC2000 Maintenance Changing the Filter DrierReplacing the External Source Tank Replacing the Printer Paper Replacing the Refrigerant Identifier Filter Parts and Service PartsService Centers California CanadaPage World Headquarters Hunt Valley Circle, New Kensington, PA

2072-0400 specifications

Bacharach 2072-0400 is a state-of-the-art combustion analyzer that stands out in the field of HVAC and building performance testing. Designed primarily for technicians and professionals, this innovative device is equipped with advanced sensing technologies that enable accurate measurement of multiple combustion parameters, ensuring that heating systems operate efficiently and safely.

One of the main features of the Bacharach 2072-0400 is its ability to measure combustion gases, including carbon monoxide, carbon dioxide, oxygen levels, and flue gas temperature. This capability allows technicians to conduct thorough analyses of heating systems, ensuring that they are not only efficient but also compliant with safety standards. By providing real-time data, the device assists technicians in identifying potential issues before they escalate, ultimately contributing to improved system longevity and reduced emissions.

Another highlight of the Bacharach 2072-0400 is its user-friendly design. The device boasts a clear, backlit LCD screen that presents data in an easy-to-read format. Intuitive navigation through its menus ensures that users can quickly access various functions without extensive training. Additionally, the compact and lightweight design of the analyzer makes it convenient for on-site use in a variety of environments.

In terms of technology, the Bacharach 2072-0400 incorporates state-of-the-art sensors that enhance measurement accuracy and reliability. The device utilizes infrared technology for measuring carbon dioxide and temperature, while electrochemical sensors are employed for carbon monoxide detection. These technologies collectively ensure that users receive precise readings, contributing to more informed decision-making during system evaluations.

Furthermore, the Bacharach 2072-0400 includes features such as data logging capabilities, which allow users to store and retrieve measurements for later analysis. This functionality is particularly beneficial for contractors needing to document system performance or for those who must comply with regulatory requirements.

The analyzer also supports easy connectivity options, enabling users to transfer data to laptops or mobile devices for further analysis or reporting. This level of connectivity ensures that the results can be easily communicated to clients or stakeholders, enhancing the professional image of technicians using the device.

Overall, the Bacharach 2072-0400 is an indispensable tool for modern HVAC professionals. With its comprehensive measurement capabilities, advanced sensor technology, user-friendly interface, and data management features, the device sets a new standard in combustion analysis. As energy efficiency and environmental impact become increasingly important, the Bacharach 2072-0400 provides the essential insights needed to optimize combustion systems effectively.