Bosch Appliances LBB 1965 manual Controls, Environmental conditions, General

Page 23

Plena Message Manager Installation and Operating Manual Technical data

en 23

5.5 Controls

Trigger inputs (Screw)

 

Activation

contact closure

Supervision

on trigger inputs 1-6, selectable

Supervision method

loop resistance check

Control outputs (Screw)

 

Message active relay

100 V, 2 A (voltage free, SPDT)

Fault relay

100 V, 2 A (voltage free, SPDT)

RS232 (9-pin D-sub)

 

PC to LBB1965/00

115 kb/s, N, 8, 1, 0 (upload)

LBB1965/00 to LBB1925/10

19.2 kb/s, N, 8, 1, 0 (zone control)

5.6 Environmental conditions

Operating temperature range

-10 to +55 °C

Storage temperature range

-40 to +70 °C

Relative humidity

< 95%

5.7 General

EMC emission

acc. to EN 55103-1

EMC immunity

acc. to EN 55103-2

Dimensions

56 x 430 x 270 mm (19wide, 1U high, with feet)

Weight

approx. 3 kg

19mounting brackets

included

Bosch Security Systems 2003-09 9922 141 50502en

Image 23
Contents Plena Message Manager Page Important safeguards About this manual Safety precautionsTable of contents Bosch Security Systems 2003-09 9922 141 50502en Mains About the equipmentCapacity FeaturesPackage Controls and indicators frontLoop through Supervision Controls and connections rearInstallation in rack Connecting the DC supply battery External settings and connectionsLBB1965 Normal audio connectionsLBB1920 Loopthrough audio connectionsTrigger input connections Mains connection Uploading OperationBosch Security Systems 2003-09 9922 141 50502en Play-back messages Manual editing of messages MonitoringSupervision Bosch Security Systems 2003-09 9922 141 50502en Inputs Technical dataElectrical MessagesGeneral ControlsEnvironmental conditions Plena Message Manager Installation and Operating Manual Page For more information visit