The High Mounting Eagle Motion Detector (PN: 10EAGLE1HM) nd technology combined with digital processing to assure a

DESCRIPTION sharp, stable activation pattern with outstanding adjustability. Some of the adjustments include unidirectional sensing capabilities, 3-dimensional angle adjustment, and heightened immunity to highly sensitive motion settings. These adjustments can be made with BEA’s universal remote control. Other accessories available for the Eagle include the false ceiling adapter (ECA), and the rain protection cover (ERA).

PRELIMINARY

TECHNICAL SPECIFICATIONS

Frequency:

24.125 GHz

Supply voltage:

12 to 24 V AC : ± 10% :

 

12 to 24 V DC : -10% / +30% :

Mounting height:

16.5 feet

Tilt angle:

0° to 90° vertical

 

-30°to +30° lateral

Detection area:

13.1 ft x 8.2 ft

Minimum detection speed:

2in/sec. (measured in axis)

Power consumption:

< 2 W

Standard output relay:

 

Max contact voltage

60 VDC / 125 VAC

Max contact current

1 A (resistive)

Max switching power

30W (DC) / 60VA (AC)

Hold time:

0.5 sec. to 9 sec. (adjustable)

Temperature range:

-4°F to 131°F

Dimensions:

4.75in (W) x 3.15in (H) x 2.0in (D)

Weight:

0.5lbs

Material:

ABS

Housing color:

Black. Can be painted with non-metallic paint

Cable length:

30ft

DESCRIPTION OF THE SENSOR

 

Manual Set-up

Terminal Block

Buttons

Wire

 

 

Passage

 

 

Hole

Planar

Lateral Adj.

 

 

For Antenna

 

Antenna

 

 

INSTALLATION TIPS

The sensor must be firmly fastened in order not to vibrate.

75.1038 V2 Aug 2001 [Rev. June 10, 2005]

The sensor must not be placed directly behind a panel or any kind of material.

The sensor must not have any object likely to move or vibrate in its sensing field.

The sensor must not have any fluorescent lighting in its sensing field.

Page 1 of 8

Image 1
Contents Installation Tips Technical SpecificationsABS Description of the SensorMechanical Installation Opening Sensor Safety PrecautionsMechanical Installation Preparation For Mounting Sensor Electrical Installation Cabling & ConnectionWidth of the Sensing Field Mechanical Adjustments Setting the Sensing Field DimensionsCont Mechanical Adjustments Setting Sensing Field DimensionsUNI-DIRECTIONAL Mode BI-DIRECTIONAL ModeUNI-DIRECTIONAL Mode with MTF The principle is as follows ControlUnlocking & Locking Manual SET-UP ProgrammingButtons + Plus and Minus TroublePN 10ECA Other AccessoriesPN 10EMB PN 10ERA