Universal Security Instruments MICN102L, MICN109L warranty Alarm Limitations and Functions

Page 2

ALARM LIMITATIONS AND FUNCTIONS

This Combination Ionization Smoke/Carbon Monoxide (CO)/Natural Gas alarm requires constant 120 VAC power to operate properly.

There are three basic smoke alarm types: IoPhic® , Ionization and Photoelectric.

IoPhic® is an ionization alarm containing a patent-pending Universal Smoke Sensing Technology. IoPhic® alarms are very effective at detecting fast flaming fires and also respond very quickly to slow smoldering fires - up to 87% faster than the maximum allowable alarm limit (UL217 Smoldering Smoke Test on 5/26/2010, Underwriters Laboratories Project #09CA38078).

Ionization smoke alarms are typically more effective at detecting fast flaming fires - fires which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a wastebasket, or kitchen grease fires.

Photoelectric smoke alarms, on the other hand, are typically more effective at detecting slow smoldering fires - fires which burn for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding.

Installing IoPhic® smoke alarms ensures maximum detection of both types of fires from a single alarm, while eliminating the need for a combination of ionization and photoelectric smoke alarms.

The enclosed alarm is a Smoke, CO and Natural Gas alarm.

SMOKE ALARMS WILL NOT WORK DURING A LOSS OF POWER. SINCE A SMOKE ALARM WILL NOT WORK WITHOUT POWER, having an alarm(s) that works from two completely different power sources, such as an AC direct wire with battery backup smoke alarm, can give you an extra measure of protection in case of an AC power failure or a dead battery. Battery operated alarms cannot work if the batteries are missing, disconnected or dead, if the wrong type of batteries are used or if the batteries are not installed correctly. AC (only) powered alarms cannot work if the AC power is cut off for any reason. If you are concerned about the limitations of the battery or AC power, install both types of alarms.

CO/NATURAL GAS alarms are designed to detect carbon monoxide and natural gases from any source of combustion or natural gas leakage that reaches their sensor.

USING AN IONIZATION SMOKE ALARM IN A SMOKY AREA, SUCH AS A KITCHEN, OR IN A HIGH HUMIDITY AREA NEAR A SHOWER, CAN CAUSE NUISANCE FALSE ALARMS. IT IS PREFERABLE TO USE PHOTOELECTRIC ALARMS IN THESE AREAS. DO NOT TURN OFF THE AC POWER TO QUIET THE ALARM. A SMOKE ALARM WILL NOT HELP PROTECT YOU IF IT IS NOT POWERED. Properly locate your alarm to avoid nuisance alarms.

A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED, VIOLENT EXPLOSIONS, ESCAPING GAS, IMPROPER STORAGE OF FLAMMABLE MATERIALS, OVERLOADED ELECTRICAL CIRCUITS, CHILDREN PLAYING WITH MATCHES, NATURAL CAUSES SUCH AS LIGHTNING, OR ARSON. FIRE PREVENTION IS YOUR BEST SAFEGUARD.

INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSURANCE RATES, BUT SMOKE ALARMS ARE NOT A SUBSTITUTE FOR INSURANCE. Homeowners and renters alike should continue to insure their lives and properties.

SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM. Smoke from fires may not reach the sensing chamber and set off the alarm. One alarm should be installed inside each bedroom or sleeping area. Do not obstruct airflow around the smoke alarm or place in areas of obstructed airflow.

BE AWARE OF VARIOUS SITUATIONS AGAINST WHICH THE SMOKE ALARM MAY NOT BE EFFECTIVE. For example: (1) Fires where the victim is intimate with a flaming initiated fire; for example, when a person's clothes catch fire while cooking; (2) Fires where the smoke is prevented from reaching the alarm due to a closed door or other obstruction or (3) Incendiary fires where the fire grows so rapidly that an occupant's egress is blocked even with properly located alarms.

SMOKE ALARMS MAY NOT DETECT FIRE ON ANOTHER FLOOR OR AREA OF THE HOME. Recommended minimum protection is at least one smoke alarm in every sleeping area and every bedroom on every level of your home. Interconnected smoke alarms may provide earlier warning than stand-alone smoke alarms since all smoke alarms alarm when one detects smoke.

SMOKE ALARMS MAY NOT BE HEARD. The alarm horn in this alarm meets or exceeds current standards, but it may not be heard if: (1) the smoke alarm is located outside a closed or partially closed door; (2) residents recently consumed alcohol or drugs; (3) the alarm is drowned out by noise from stereos, TV's, air conditioners or other appliances; (4) residents are hearing impaired or (5) if residents are sleeping.

CURRENT STUDIES HAVE SHOWN SMOKE ALARMS MAY NOT AWAKEN ALL SLEEPING INDIVIDUALS AND THAT IT IS THE RESPONSIBILITY OF INDIVIDUALS IN THE HOUSEHOLD WHO ARE CAPABLE OF ASSISTING OTHERS TO PROVIDE ASSISTANCE TO THOSE WHO MAY NOT BE AWAKENED BY THE ALARM SOUND OR TO THOSE WHO MAY BE INCAPABLE OF SAFELY EVACUATING THE AREA UNASSISTED.

SMOKE ALARMS ARE NOT FOOLPROOF. You must test the smoke alarm weekly to ensure your continued protection. Smoke alarms cannot prevent or extinguish fires.

COMBINATION CO/NATURAL GAS/SMOKE ALARMS HAVE A LIMITED LIFE. The Combination CO/ Natural Gas/Smoke alarm should be replaced immediately if it is not operating properly. You should always replace a Combination CO/Natural Gas/Smoke alarm after 7 years.

SMOKE ALARMS ARE NOT TO BE USED WITH DETECTOR GUARDS UNLESS THE COMBINATION HAS BEEN EVALUATED AND FOUND SUITABLE FOR THAT PURPOSE.

Image 2
Contents Table of Contents Alarm Limitations and Functions What YOU should Know about Natural GAS Where this Alarm should be InstalledWhat YOU should Know about CO Page Basic Safety Information Where YOU can Hear the Alarm from ALL Sleeping AreasPage Electrical Shock Hazard Do not Tamper with Wires When Power is on Wiring InstructionsWires from Quick Connectorconnect to OPERATION, Testing & Maintenance What to do if Carbon Monoxide is Detected If Your CO and GAS Alarm SoundsIf the CO Alarm Sounds Using the Silence Feature What to do if Natural GAS is DetectedUtha Maintenance Regular MaintenanceWeekly Testing Using the Test FeatureCO and Natural GAS Alarm Limitations Potential Sources of CO in the HomeDevelop and Practice a Plan of Escape Basics of Escape Plan Repairs and ServicesHOW can I Protect MY Family from CO POISONING? What to do When the Alarm Sounds FCC Part 15 Radio Frequency DevicesOperational Summary RecommendationAlarm Returns TEN Year Lithium Battery Limited WarrantyUltralife 9 Volt Battery Returns

MICN109, MICN109L, MICN102, MICN102L specifications

Universal Security Instruments offers a versatile lineup of carbon monoxide and smoke detectors that provide essential safety features for any home or office environment. Among their popular models are the MICN102, MICN109L, MICN109, and MICN102L, each designed with advanced technology to ensure effective monitoring and protection against fire and carbon monoxide threats.

The MICN102 is a dual-sensor alarm, combining both smoke and carbon monoxide detection in a single unit. This compact device features an electrochemical sensor for precise CO detection, as well as an ionization smoke sensor that responds quickly to fast-flaming fires. With a loud alarm of 85 decibels, homeowners can rely on timely notifications in the event of emergencies. The MICN102 is also equipped with a test and silence button, allowing for easy routine checks and the ability to silence false alarms.

The MICN109L is an enhanced model that includes a voice alert feature. This model not only emits a loud alarm but also provides clear spoken alerts, indicating whether smoke or carbon monoxide has been detected, significantly improving user awareness and response times. With its user-friendly design, the MICN109L also has an easy-to-read display that shows the current CO levels, allowing users to stay informed about their indoor air quality.

The MICN109 shares many of the same core features found in the MICN109L, including the dual-sensor technology and 85-decibel alarm, but does not include the voice alert function. This model still offers reliable and efficient monitoring, making it an excellent choice for individuals looking for solid protection without additional features.

Lastly, the MICN102L combines the effective detection capabilities of the MICN102 with voice alerts similar to those in the MICN109L. This model is particularly beneficial for larger households or spaces where quick identification of the type of threat may be crucial. Features such as battery backup ensure continuous protection even during power outages, while the easy-to-install design allows for swift setup.

Across all models, Universal Security Instruments emphasizes user-friendly operation, reliability, and effective detection, providing peace of mind for families and individuals alike. With their modern design and advanced safety features, these units stand out as trusted guardians against fire and carbon monoxide hazards, reflecting Universal Security Instruments’ commitment to quality and safety.