TOA Electronics VFST-CMN-2 dimensions Optional Equipment, Forced Air Kit, Remote Control Kit

Page 11

Step 9. Checking the System – With gas line installed run initial system checkout before closing up the front of the unit. Follow the pilot lighting instructions on page 15.

Note: Instructions are also found on the pull out panel located on the bottom surface of the appliance.

When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the instruc- tion manual. Subsequent lightings of the appli- ance will not require such purging. Inspect the pilot flame (remove logs, if necessary, handling carefully).

The pilot flame should be steady, not lifting or floating. Flame should be blue in color with traces of orange at the outer edge.

The top 3/8" (10 mm) at the pilot generator (thermocouple) should be engulfed in the pilot flame (NG only).

Replace logs if removed for pilot inspection.

To light the burner; turn “ON” the optional remote wall switch (if installed) and rotate the gas valve control knob counterclockwise to the “ON” position.

Step 10. Installing the Screen Panel Assem- bly – Retrieve the screen door frame. Position the door frame in front of the firebox opening in the brackets at the base of the fireplace front opening. Lean the door frame back towards the fireplace ensuring that the frame seats evenly as it draws shut.

Install the three (3) 1/4"-20 x 1" Phillips pan head screws removed previously and tighten to secure.

Installing the Optional Glass Door

Position the door frame in front of the firebox opening, with the joint in the gasket down. Locate the three (3) tabs at the bottom edge of the door frame into the three (3) brackets at the base of the fireplace front opening. Lean the door frame back towards the fireplace ensuring that the frame seats evenly as it draws shut.

Figure 19

OPTIONAL EQUIPMENT

An incomparable package of options are avail- able for use with these appliances. These op- tions can both customize the operation of these unique appliances and enhance their beauty and charming appeal. All options are available in kit form, are easy to install and are packaged complete with all required parts and instruc- tions. Some of the option kits need to be fitted prior to completing the installation of the appli- ance. The following paragraphs detail the kit options available for use with the appliances covered in this manual.

These outstanding optional items can be added individually or in sets of two or more to cus- tomize your vent-free appliance to fit your homes unique needs.

The appliances covered in this manual are heater rated and produce a great deal of heat. Decorative brass trim pieces and hoods may tarnish because of their proximity to the heater opening and front face. Tarnishing of these pieces is normal, unavoidable and should be expected.

Forced Air Kit

The FAB-1100 assembly provides a forced air circulation feature for your appliance. This kit mounts directly into the lower intake chamber with an electrical connection made at the recep- tacle provided. The appliance must have an independent 120Vac power line incorporated at the time of installation. Refer to Step 6 of the installation instructions supplied with the forced air kit (Figures 20 and 21 ).

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Figure 20

Blower Motor

Grounded

to Appliance

Motor Plug

Receptacle

120V

Appliance Junction Box

Figure 21

Remote Control Kit

The Model RCL adds the convenience of re- mote control for your appliance. The kit in- cludes a wireless, hand held transmitter and a receiver that replaces the wall switch. This special receiver permits either manual or re- mote control modes. Both receiver and trans- mitter operate on standard 9 volt batteries (not included). Refer to the RCL installation instruc- tion for specific details.

Wall Switch Kit

An optional wall switch kit can be installed along with all vent-free appliances. The kit consists of a standard UL wall switch with cover plate. This kit provides for remote (wall) operation of the appliance. Replace the wall switch and cover plate of this kit with the components of the FWSK and you can have true remote control of your vent-free appliance, turning it on and off from your favorite easy chair. The wall switch kit should be installed along with the appliance. Refer to Figure 13 and Step 6 for detailed installation instructions.

11

Image 11
Contents Unvented Decorative Gas Fireplaces 903571 REV. H 12/2007 Consumer Retain this manual for future referenceTable of Contents Massachusetts CodesMassachusetts And New York Require- ments Combustion and Ventilation AIRExample Location of FireplaceClearances Check Gas Type PreinstallationAssembly Steps Installation StepsFraming Dimensions Vfst Appliance SpecificationsVfst Framing Specifications 43 1092 mm Min 22-3/4 578 mm40-1/8 1016 mm Min Gas Flex Line Kit, Model Gflv Finished Wall Details Vfst Series Standard Wiring DiagramFlame Appearance Assembling the LogsOptional Equipment Remote Control KitWall Switch Kit Installing the Optional Glass DoorWall Thermostat Kit Optional on Unit Rocker SwitchSolid Brass Hood Kit Solid Brass Louver KitOperation and Care of Your Appliance Cleaning and ServicingReplacement Parts Accessories and ComponentsKit Possible Cause Remedy Observed ProblemLighting Instructions For Your Safety Read Before LightingOperating Instructions What to do if YOU Smell GASTurn Control Knob to on Position Turn Control Knob to OFF Position PilotTurn Control Knob to Pilot Position Pilot LocationDescription Vfst Replacement Parts ListVFST-CMN Replacement Parts Vfst VFPF-CMN Vfpf Replacement Parts ListReplacement Parts Vfpf Page Page Orange, CA 903571 REV. H 12/2007

VFST-CMN-2 specifications

The TOA Electronics VFST-CMN-2 is a top-tier public address system speaker that epitomizes the fusion of technology and audio excellence. Renowned for its superior sound quality, this speaker is designed primarily for commercial, institutional, and outdoor environments. One of its standout features is its remarkable versatility, making it suitable for various applications, including schools, shopping centers, and outdoor events.

A key characteristic of the VFST-CMN-2 is its robust construction. Designed to withstand challenging conditions, the cabinet is made from high-impact ABS plastic, ensuring durability and longevity. This makes it an ideal choice for use in outdoor settings where exposure to the elements is a concern. Additionally, the speaker is equipped with a weather-resistant grille that helps protect the internal components from moisture and debris, further enhancing its suitability for external applications.

The VFST-CMN-2 also boasts an impressive frequency response, which allows it to deliver crystal-clear sound across a wide range of audio frequencies. Its ability to reproduce low, mid, and high frequencies ensures that announcements and music are clear and intelligible, making it an excellent choice for diverse audio needs. Complementing its sound capabilities, this speaker is equipped with high-efficiency drivers that maximize audio output while minimizing distortion.

Furthermore, the VFST-CMN-2 incorporates advanced technology that allows for easy installation and configuration. It features a dual voltage transformer that provides flexibility, enabling the speaker to operate at both 100V and 70V systems, catering to various installation requirements. The integrated mounting brackets make installation straightforward, allowing users to quickly position the speaker for optimal sound distribution.

The design of the VFST-CMN-2 also emphasizes aesthetics, maintaining a sleek and modern look that blends well with any environment. Its lightweight design facilitates mobility, allowing users to easily relocate the speaker as needed.

In conclusion, the TOA Electronics VFST-CMN-2 is a powerful and resilient speaker system that delivers exceptional performance across different settings. With its durable construction, superior audio quality, and user-friendly features, it stands out as a premier solution for any public address or sound reinforcement needs. Whether used in an educational institution, commercial space, or at an outdoor event, the VFST-CMN-2 ensures clear communication and an outstanding listening experience.