TOA Electronics VF5000-CMP-2 Remote Control Kit, Wall Switch Kit, Rocker Switch Kit

Page 11

Blower Motor

Grounded

to Appliance

Motor Plug

Receptacle

120V

Appliance Junction Box

Figure 23

Remote Control Kit

The Model RCL adds the convenience of re- mote control for your appliance. The kit in- cludes a wireless, hand held transmitter and a receiver that replaces the wall switch. This special receiver permits either manual or re- mote control modes. Both receiver and trans- mitter operate on standard 9 volt batteries (not included). Refer to the RCL installation instruc- tion for specific details.

Wall Switch Kit

An optional wall switch kit can be installed along with all vent-free appliances. The kit consists of a standard UL wall switch with cover plate. This kit provides for remote (wall) operation of the appliance. Replace the wall switch and cover plate of this kit with the components of the FWSK and you can have true remote control of your vent-free appliance, turning it on and off from your favorite easy chair. The wall switch kit should be installed along with the appliance. Refer to Figure 14 and Step 6 for detailed installation instructions.

Rocker Switch Kit

An optional rocker switch kit can be installed directly on all VF5000/VF6000 series appli- ances to provide for On and Off operation in lieu of a wall switch. This kit is designed to install in the lower control compartment out of view and is perfect for use in high volume areas such as lobbies and model homes where limited access to the appliance On/Off switch is desirable. This kit can be retrofitted to previously installed appliances and may be temporarily installed in place of other switch circuitry.

Decorative Volcanic Stone

The decorative volcanic stone, Model FDVS, can be used to enhance the look of your appli- ance. Spread the decorative volcanic stone evenly around the bottom of the firebox.

Refractory Liner Kit

One of the most beautiful enhancements you can make to this appliance is the addition of refrac- tory liners. The refractory liner kit includes tan ceramic fiber panels for the rear and side walls of the firebox. The ceramic fiber panels have brick- like features in relief. To install the three panels, simply place them in position against the firebox walls. This kit can be retrofitted into previously installed appliances.

Glass Door Kit

Optional glass door kits are available for use with both the VF5 and VF6 appliances. These doors elegantly provide protection for the logs while helping to prevent the buildup of con- taminates such as pet hair, carpet lint and dust on the burner ports. Use the GDK-5 with VF5 appliances and the GDK-6 with VF6 appli- ances.

Solid Brass Hood Kit

An attractive solid brass hood kit is available for use with these VF appliances. The brass hood kit is designed to be fitted to your appli- ance above the door. In addition to providing an aesthetically pleasing appearance to your appliance installation, the hood reduces heat effects to decorative mantles and finish mate- rials located directly above the fireplace open- ing. The hood kit includes the necessary attaching hardware. This kit can be retrofitted to previously installed appliances.

Solid Brass Louver Kit

Solid brass louvers are available for use with these appliances. These louvers are designed to replace the standard black louvers that are provided with the appliance. The brass louver kit includes four (4) louvers that simply snap into place. They provide a touch of elegance to the VF appliance. This kit can be retrofitted to previously installed appliances.

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Screen Panel Kit

An optional screen panel can be installed on the VF5000/VF6000 Series Units. This screen panel is easy to install. This kit can be retrofitted to previously installed VF5000/VF6000 appliances.

One Piece Arch Kit

A one piece complete door arch kit is available for use with VF appliances fitted with the op- tional GDK-5/6 door. This kit is easy to install and does not require hardware to attach it to a previously installed optional door frame. The kit can be retrofitted to previously installed appliances.

Gas Flex Line with Valve

A gas flex line kit is available to aid in attaching the appliance to the gas supply. This kit can only be used where local codes permit. The kit includes a 1/2" NPT to 3/8" flare in line shut-off valve, a 12" flex line 3/8" female flare through and a 3/8" flare to 3/8" NPT fitting. The compo- nents of this kit are rated for both natural and propane gas. This kit is designed to be used as an aid in installing the appliance.

WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE SUPER- VISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

Wall Thermostat Kit

A wall thermostat kit is available for use with these appliances. The wall thermostat is de- signed to be wired directly to the appliance millivolt gas control circuit and provide auto- matic On/Off control of the appliance to main- tain a desired temperature within the room.

Brass Square Surround Kit

Decorative brass square surround kits are avail- able for use with these appliances. The BSK-5 and BSK-6 are designed to attach directly to the front face of the appliance at its extreme edges. The brass square surround kits provide a pic- ture frame finish for the appliance 2-1/2" wide. Use the BSK-5 with VF5 appliances and the BSK-6 with VF6 appliances. The brass square surround kit can be retrofitted onto previously installed appliances.

11

Image 11
Contents Unvented Decorative Gas Fireplaces 903302 REV. M 12/2007 Consumer Retain this manual for future referenceTable of Contents Massachusetts CodesMassachusetts And New York Require- ments Combustion and Ventilation AIRExample Location of FireplaceCheck Gas Type PreinstallationClearances Built-In Systems Installation StepsGas Flex Line Kit, Model Gflv Finished Wall Details Surround InstallationsFlame Appearance Connecting Gas LineAssembling the Logs Appliance Operation Installing the Optional Glass DoorOptional Equipment Forced Air KitDecorative Volcanic Stone Remote Control KitWall Switch Kit Rocker Switch KitOperation and Care of Your Appliance Cleaning and ServicingReplacement Parts Accessories and ComponentsBSK-5 VF6000 Specifications VF5000 SpecificationsPossible Cause Remedy Guide for Unvented GAS ProductsTo Turn OFF GAS to Appliance For Your Safety Read Before LightingLighting Instructions Millivolt Lighting InstructionsPage Description Replacement Parts ListVF6000-CMN VF6000-CMPSIT Valve Shown Replacement Parts903302 REV. M 12/2007