VF5000/VF6000 Series
Standard Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire.
From Thermocouple
* *
TH | Thermopile |
TP |
|
TPTH |
|
* For Rocker or ON/OFF Wall Switch Attachment Only.
Figure 13
VF5000/VF6000 Series
Optional Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire.
From Thermocouple
| Optional ON/OFF | |
| Wall Switch/Rocker Switch | |
| * | * |
TH | Thermopile |
|
|
| |
TP |
|
|
TPTH |
|
|
Factory Wired | Field Wired |
* For Rocker Switch Attachment Only.
Figure 14
IMPORTANT: Ground lead must be connected to the green screw located on the junction box cover plate. Failure to do so will prevent the appliance from operating. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA
The forced air blower kit may be mounted at initial appliance installation or at any time there- after. Follow the instructions provided with the blower kit.
Finished Wall Details
It is sometimes best to frame the appliance after it has been positioned in place. Frame with 2 x 4s or heavier lumber. Always frame in accordance with local building codes.
8
OFF/ON Blower
Wall Switch
| To Fuse or |
Black | Circuit Breaker |
| |
Receptacle | 120V |
White | }60HzAC |
Fireplace |
|
Junction Box |
|
Blower Wiring Diagram
Ground Wire
Connection
White |
|
|
(Supply) |
| Blower |
|
| |
|
| (Lower) |
|
| Outlet |
120 Vac |
|
|
60 Hz | Bipolar |
|
|
| |
| Terminal |
|
Black | Screw | Black |
(Supply) |
| Wire |
Mating
Connectors
Red Wire
Figure 15
Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
Note: The header may rest on the top spacers but must not be notched to fit around them.
In order to install the appliance facing flush with the finished wall, position the framework to accommodate the thickness of the finished wall (Refer to Figures 2 and 3 ).
If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.
Proceed to Step 12.
Surround Installations
Note: The VF5000/VF6000 series appliances must be installed giving full consideration to the clearance and height requirements identi- fied in this manual.
Figure 16