TOA Electronics VF5000-CMP-2 operating instructions Surround Installations, Finished Wall Details

Page 8

VF5000/VF6000 Series

Standard Wiring Diagram

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire.

From Thermocouple

* *

TH

Thermopile

TP

 

TPTH

 

* For Rocker or ON/OFF Wall Switch Attachment Only.

Figure 13

VF5000/VF6000 Series

Optional Wiring Diagram

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire.

From Thermocouple

 

Optional ON/OFF

 

Wall Switch/Rocker Switch

 

*

*

TH

Thermopile

 

 

 

TP

 

 

TPTH

 

 

Factory Wired

Field Wired

* For Rocker Switch Attachment Only.

Figure 14

IMPORTANT: Ground lead must be connected to the green screw located on the junction box cover plate. Failure to do so will prevent the appliance from operating. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70-(latest edition). (In Canada, the current CSA C22-1 Canadian Electrical Code.)

The forced air blower kit may be mounted at initial appliance installation or at any time there- after. Follow the instructions provided with the blower kit.

Finished Wall Details

It is sometimes best to frame the appliance after it has been positioned in place. Frame with 2 x 4s or heavier lumber. Always frame in accordance with local building codes.

8

OFF/ON Blower

Wall Switch

 

To Fuse or

Black

Circuit Breaker

 

Receptacle

120V

White

}60HzAC

Fireplace

 

Junction Box

 

Blower Wiring Diagram

Ground Wire

Connection

White

 

 

(Supply)

 

Blower

 

 

 

 

(Lower)

 

 

Outlet

120 Vac

 

 

60 Hz

Bipolar

 

 

 

 

Terminal

 

Black

Screw

Black

(Supply)

 

Wire

Mating

Connectors

Red Wire

Figure 15

Note: Supply wires may be alternatively connected to the outlet using the screw terminals, however the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is attached to and the white supply wire must be connected to the opposite side of the outlet.

NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.

Note: The header may rest on the top spacers but must not be notched to fit around them.

In order to install the appliance facing flush with the finished wall, position the framework to accommodate the thickness of the finished wall (Refer to Figures 2 and 3 ).

If you live in a cold climate, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level.

Proceed to Step 12.

Surround Installations

Note: The VF5000/VF6000 series appliances must be installed giving full consideration to the clearance and height requirements identi- fied in this manual.

Figure 16

Image 8
Contents Consumer Retain this manual for future reference Unvented Decorative Gas Fireplaces 903302 REV. M 12/2007Table of Contents Codes Massachusetts And New York Require- mentsCombustion and Ventilation AIR MassachusettsLocation of Fireplace ExampleCheck Gas Type PreinstallationClearances Installation Steps Built-In SystemsGas Flex Line Kit, Model Gflv Surround Installations Finished Wall DetailsFlame Appearance Connecting Gas LineAssembling the Logs Installing the Optional Glass Door Optional EquipmentForced Air Kit Appliance OperationRemote Control Kit Wall Switch KitRocker Switch Kit Decorative Volcanic StoneCleaning and Servicing Replacement PartsAccessories and Components Operation and Care of Your ApplianceBSK-5 VF5000 Specifications VF6000 SpecificationsGuide for Unvented GAS Products Possible Cause RemedyFor Your Safety Read Before Lighting Lighting Instructions MillivoltLighting Instructions To Turn OFF GAS to AppliancePage Replacement Parts List VF6000-CMNVF6000-CMP DescriptionReplacement Parts SIT Valve Shown903302 REV. M 12/2007