Note: Framing dimensions in Figures 4 - 9 are calculated for a nailing flange depth of ¹⁄₂" (13 mm).
| Back Wall of |
| Back Wall of | |
| Chase/Enclosure |
| Chase/Enclosure | |
Outside Wall | Including Finishing | Outside Wall | Including Finishing | |
Materials If Any. | Materials If Any. | |||
|
|
INSTALLATION STEPS
Built-In Systems
WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE. AVOID ANY DRAFTS THAT ALTER BURNER FLAME PATTERNS.
15 1/2"
(394mm)
37" (940mm)
VF5000
Figure 4
Back Wall of
Chase/Enclosure
Including Finishing
Materials If Any.
41"
(1041mm)
13 1/2"
(343mm)
29"
(737mm)
37" (940mm)
58" (1473mm)
VF5000
Figure 5
19 1/2"
(495mm)
41" (1041mm)
VF6000
Figure 7
Back Wall of
Chase/Enclosure
Including Finishing
Materials If Any.
47 7/8"
(1216mm)
14 1/4"
(362mm)
33 7/8"
(860mm)
41" (1041mm) 67 3/4" (1721mm)
VF6000
Figure 8
WARNING: DO NOT USE A BLOWER IN- SERT, HEAT EXCHANGER INSERT OR OTHER ACCESSORY NOT APPROVED FOR USE WITH THIS HEATER.
Do not burn solid fuels in this listed unvented gas room heater.
Step 1. Frame VF5000 appliance enclosures as illustrated in Figures 4, 5 and 6. Frame VF6000 appliance enclousures as illustrated in Figures 7, 8 and 9 for surround installations proceed to Step 8.
Note: The framed depth
Step 2. Route a 1/2" (13 mm) gas line along the left or right side framing (Figure 10 ).
6
371/4"
(946 mm)
15 1/2" (394 mm)
37" (940 mm)
Figure 6
VF5000
423/8"
(1076 mm)
19 1/2" (495 mm)
41" (1041 mm)
VF6000
Figure 9
The header may be in direct contact with the top metal spacers, but must not rest on them or be notched to fit around them.
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
3" | VF6000 - 11" | |
(76 mm) | (279 mm) | |
|
| |
|
| VF5000 - 7 1/2" |
|
| (191 mm) |
|
|
Figure 10
All appliances have a 3" long 3/8" NPT nipple installed at the valve. To quickly and easily complete the gas line routing, use the gas flex line kit, Model GFLV.