Linksys RDI-36-H HCI-36-H installation instructions Table of Contents

Page 2

2

TABLE OF CONTENTS

 

 

Safety Rules

page

2

Tools and Building Supplies

page

2

Precautions

page

3

Introduction

page

3

Clearances/Height Requirements

page

3

Chimney System

page

3

Assembly Outline

page

4

Location of Fireplace

page

4

Assembly Steps

page

5

Preinstallation Notes

page

5

Clearances

page

5

Installing the Fireplace

page

5

Fireplace Specifications

page

6

Framing Specifications

page

7

Installing the Chimney System

page

8

30° Offset through Floor/Ceiling

page

9

Ten Foot Rule Summary

page 11

Multiple Terminations

page 11

Chimney Component Calculations ...

page 11

Special Offset Instructions

page 12

Offset Calculations

page 12

Vertical Elevation Chart

page 12

Offset Elevation Chart

page 13

Installing Offsets

page 14

Optional Equipment Considerations . page 14

Forced Air Kits

page 14

Combustion Air Kits

page 15

Gas Line Connection

page 15

Vent Free Appliances

page 15

Glass Doors

page 16

Cold Climate Insulation

page 16

Fireplace Finishes

page 16

Mantels and Trim

page 16

Hearth Extensions/Wall Shields

page 16

Finish Requirements

page 18

Installation Components

page 19

IMPORTANT: PLEASE READ AND UNDERSTAND THESE RULES TO FOLLOW FOR SAFETY.

1.Before starting your fireplace installation, read these installation instructions carefully to be sure you understand them completely and in entirety. Failure to follow them could cause a fireplace malfunction resulting in serious injury and/or property damage.

2.Always check your local building codes. The installation must comply with all local, regional, state and national codes and regulations.

3.These fireplaces must be installed with Security Chimneys FTF8 (8" inside diameter) Chimney System only. These systems are in- tended for use in any application where a traditional masonry type fireplace would ap- ply. The chimney system must always vent to the outside of the building.

4.To ensure a safe fireplace system and to prevent the build-up of soot and creosote, inspect and clean the fireplace and chimney prior to use and periodically during the heating season.

5.Use solid fuel only. DO NOT use artificial wax based logs, chemical chimney cleaners or flame colorants in your fireplace.

6.DO NOT use charcoal or coal under any circumstances.

7.NEVER use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this fireplace. Keep any flammable liquids a safe distance from the fireplace.

8.NEVER leave children unattended when there is a fire burning in the fireplace.

9.Always keep flue damper open when heat is present in the fireplace.

10.Before servicing, allow the fireplace to cool. Always shut off any electricity or gas to the fireplace while working on it. This will prevent any possible electrical shock or burns.

11.This fireplace is not intended to heat an entire home or be used as a primary heat source. It is designed to ensure homeowner comfort by providing supplemental heat to the room.

12.Always ensure an that adequate supply of replacement combustion air from the outside of the house is accessible to the fire to support normal combustion. Fireplaces consume large volumes of air during the normal combustion process. In the event the home is tightly sealed with modern energy efficient features, the op- tional combustion air kit may not provide all the air required to support combustion.

The manufacturer is not responsible for any smoking or related problems that may result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that adequate combustion air has been provided for the fireplace.

13.DO NOT use a fireplace insert or any other products not specified herein by the manufac- turer for use with this fireplace. All gas log sets must be operated with the damper clamped open, including unlisted “vent free” log sets. Listed “vent-free” log sets may be operated with the damper closed.

14."Smoke free” operation is not warranteed nor are we responsible for inadequate system draft caused by mechanical systems, general construction conditions, inadequate chimney heights, adverse wind conditions and/or un- usual environmental factors or conditions be- yond our control.

15.Never, under any circumstances, install a fireplace, chimney component or any acces- sories, that has visible or suspected physical damage as a result of handling or transporta- tion. These items should be inspected by your distributor or qualified factory representative to ensure safe condition. When in doubt, con- sult your distributor.

16.For additional safety considerations and complete operating instructions, refer to the Care and Operation Manual provided with the fireplace.

TOOLS AND BUILDING SUPPLIES NORMALLY REQUIRED

Tools should Include:

Phillips screwdriver

Hammer

Saw and/or sabersaw

Level

Measuring tape

Plumb line

Electric drill and bits

Pliers

Square

Building supplies: Framing materials Wall finishing materials

Caulking materials (noncombustible) Fireplace surround and hearth extension materials (noncombustible)

Image 2
Contents WH Report No. J9902-5865C-231 Retain These Instructions For Future ReferenceWood Burning Fireplaces 850,046M REV. N/C 01/2007 Table of Contents Introduction Typical InstallationPrecautions Clearances and Height RequirementsChase Enclosure Assembly OutlineChimney Height Before You StartInstalling the Fireplace Assembly StepsPRE-INSTALLATION Notes ClearancesLeft Side Fireplace SpecificationsFront Right SideFraming Specifications 8d nails when completely installed For Canadian InstallationsInstalling the Chimney System Proceed with Steps 5 throughOr Ceiling For Canada Only12 to 12/12 Using a FTF8-CTD Round TerminationRoof Pitch Model Flat to 6/12 FTF8 Chimney Component Calculations TEN Foot Rule SummaryMultiple Terminations Offset Calculations FTF8 Vertical Elevation ChartSpecial Offset Instructions Offset Elevation Chart StabilizerReturn Elbow Assembly Installing OffsetsOffset Elbow Assembly Optional Equipment ConsiderationsVent Free Appliances Combustion Air KitsGas Line Connection Fireplace Finishes Glass DoorsCold Climate Insulation Mantels and TrimWall Shield Hearth Extension DimensionsUsing the k formula For the alternateValue = 1/k = r x thickness of material used Finish to Your TasteSum of all R values is .70 + .10 + + .10 = RM = rM x TS = 0.05 x 3/4 =Installation Components Shipping Weight850,046M REV. N/C 01/2007 Orange, CA

RDI-36-H HCI-36-H specifications

Linksys RDI-36-H HCI-36-H is a robust router designed for delivering reliable and high-performance network connectivity. Geared towards both home users and small businesses, this device integrates advanced technologies to ensure efficient data transmission and an enhanced user experience.

One of the standout features of the Linksys RDI-36-H HCI-36-H is its dual-band capability. Operating on both the 2.4 GHz and 5 GHz frequency bands, the router allows devices to connect to the less congested 5 GHz band for higher speeds, while the 2.4 GHz band provides extended range. This dual-band functionality helps minimize interference and maximizes bandwidth, making it ideal for streaming HD videos, online gaming, and other bandwidth-intensive applications.

The router is equipped with MU-MIMO (Multi-User, Multiple Input, Multiple Output) technology, which enables it to communicate with multiple devices simultaneously. This means that users can enjoy a more stable and faster connection even when numerous devices are connected at the same time. Additionally, the RDI-36-H HCI-36-H supports Beamforming technology, which focuses the Wi-Fi signal directly towards connected devices rather than just broadcasting it uniformly. This enhances connection quality and range, ensuring users experience fewer drops and interruptions.

Another significant feature of the Linksys RDI-36-H HCI-36-H is its comprehensive security features that include WPA2 encryption, ensuring that users’ data is protected from unauthorized access. Furthermore, the device offers parental controls that allow users to manage internet access for specific devices, making it easier to ensure safe browsing for children.

The router also features Gigabit Ethernet ports, providing ultra-fast wired connections for devices such as gaming consoles, smart TVs, and computers. This ensures optimal performance for bandwidth-heavy activities, reducing latency and enhancing overall user experience.

Setup and management of the Linksys RDI-36-H HCI-36-H is facilitated through a user-friendly web interface and mobile app, allowing users to customize settings and monitor network activity conveniently.

In summary, the Linksys RDI-36-H HCI-36-H is a feature-rich router that combines dual-band technology, MU-MIMO, Beamforming, and robust security features to meet the demands of modern users. Its ability to support multiple devices seamlessly while providing fast, reliable connections makes it an excellent choice for anyone looking to enhance their home or small office network.