Linksys RDI-36-H HCI-36-H Chimney Height, Chase Enclosure, Assembly Outline, Before You Start

Page 4

4

Insulate Joists

Same As Ceiling

Draft Stops

Firestop

CTDT

Termination

Note: Non-

Combustible

Chase

Flashing

Must Be

Used To

Cover

Chase

Opening

Optional

Insulation

In Outside

Walls Of

Chase

8'

Level

Solid

Continuous

Surface

 

Outside

Insulation

Base

(Thermal Barrier)

 

Figure 2

WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT. INSULATION OR VAPOR BARRIERS, IF USED, MUST FIRST BE COVERED WITH GYPSUM BOARD, PLYWOOD, PARTICLE BOARD OR OTHER MATERIAL TO ASSURE INSULATION AND VAPOR BARRIERS REMAIN IN PLACE.

WARNING: DO NOT PACK OR FILL RE- QUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL. NO MATERIAL IS ALLOWED IN THESE AREAS.

Note: Do not insulate the chase cavity with blown or fill type insulation materials.

Note: Local codes may not require firestopping at the ceiling levels for outside chase installa- tions. However, it is recommended for safety and the reduction of heat loss.

Chimney Height

The total height of your completed fireplace system from the surface the fireplace rests on to the chimney top must not exceed 60' and must also meet minimum height requirements. Refer to the minimum system height chart.

Minimum System Height

Security's FTF8 Pipe

Vertical Installation

15' 0"

 

 

One Offset

15' 0"

 

 

Two Offsets

25' 0"

 

 

Chase Enclosure

A chase is a vertical box-like structure con- structed to surround the fireplace and chimney. Refer to Figure 2 for a typical chase configura- tion. As with all chimney installations, avoid overhead obstructions such as trees, power lines, etc. A chase should be constructed and insulated just like any outside wall. In a cold climate, we recommend the base of the chase should also be insulated between the solid continuous floor beneath the fireplace and the chase bottom. Chase insulation in a cold cli- mate installation is not required for safety.

ASSEMBLY OUTLINE

Before You Start

Check your inventory list to be sure you have all the necessary parts supplied in good usable condition. Check also for any concealed damage.

Check the operation of the damper. The damper is controlled through the use of a control lever located within the firebox opening at the top center just behind the firebox lintel (Figure 3 ). The control lever snaps into place at the ex- treme range of motion, up and back in the closed position. When pulled forward and down, the damper is open.

Damper

Damper

Closed

Open

Lintel

 

 

Combustion

 

Air Actuator

Figure 3

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

LOCATION OF FIREPLACE

Carefully select the proper location for heat circulation, aesthetics, chimney obstructions and clearance to side wall(s). With proper pre- planning, a slight adjustment of a few inches can save considerable time and expense later during construction and assembly.

Hearth

Hearth

Optional

Outside Chase

Figure 4

Carefully consider the position of the fireplace opening with respect to the location of adja- cent or nearby stairwells, bath or kitchen ex- haust fans and/or return air registers for forced air furnaces/air conditioners that could cause a smoking fireplace condition if the house is tightly insulated.

When locating the fireplace, consideration must be given to combustibles and final finishing. See Figure 5 and confine the final location of combustible finish materials to the "Safe Zone".

DO NOT permanently place furniture or other items such as decorative pillows within 60" of the fireplace front face.

Black Portion Of Frame

Not To Be Covered With

Combustible Materials

Wall

12”Covering

45°

1”

Door

Opening

12” Safe

Zone

Figure 5

Image 4
Contents Wood Burning Fireplaces 850,046M REV. N/C 01/2007 Retain These Instructions For Future ReferenceWH Report No. J9902-5865C-231 Table of Contents Typical Installation PrecautionsIntroduction Clearances and Height RequirementsAssembly Outline Chimney HeightChase Enclosure Before You StartAssembly Steps PRE-INSTALLATION NotesInstalling the Fireplace ClearancesFireplace Specifications FrontLeft Side Right SideFraming Specifications For Canadian Installations Installing the Chimney System8d nails when completely installed Proceed with Steps 5 throughOr Ceiling For Canada OnlyRoof Pitch Model Flat to 6/12 Using a FTF8-CTD Round Termination12 to 12/12 Multiple Terminations TEN Foot Rule SummaryFTF8 Chimney Component Calculations Special Offset Instructions FTF8 Vertical Elevation ChartOffset Calculations Offset Elevation Chart StabilizerInstalling Offsets Offset Elbow AssemblyReturn Elbow Assembly Optional Equipment ConsiderationsGas Line Connection Combustion Air KitsVent Free Appliances Glass Doors Cold Climate InsulationFireplace Finishes Mantels and TrimHearth Extension Dimensions Using the k formulaWall Shield For the alternateFinish to Your Taste Sum of all R values is .70 + .10 + + .10 =Value = 1/k = r x thickness of material used RM = rM x TS = 0.05 x 3/4 =Installation Components Shipping Weight850,046M REV. N/C 01/2007 Orange, CA

RDI-36-H HCI-36-H specifications

Linksys RDI-36-H HCI-36-H is a robust router designed for delivering reliable and high-performance network connectivity. Geared towards both home users and small businesses, this device integrates advanced technologies to ensure efficient data transmission and an enhanced user experience.

One of the standout features of the Linksys RDI-36-H HCI-36-H is its dual-band capability. Operating on both the 2.4 GHz and 5 GHz frequency bands, the router allows devices to connect to the less congested 5 GHz band for higher speeds, while the 2.4 GHz band provides extended range. This dual-band functionality helps minimize interference and maximizes bandwidth, making it ideal for streaming HD videos, online gaming, and other bandwidth-intensive applications.

The router is equipped with MU-MIMO (Multi-User, Multiple Input, Multiple Output) technology, which enables it to communicate with multiple devices simultaneously. This means that users can enjoy a more stable and faster connection even when numerous devices are connected at the same time. Additionally, the RDI-36-H HCI-36-H supports Beamforming technology, which focuses the Wi-Fi signal directly towards connected devices rather than just broadcasting it uniformly. This enhances connection quality and range, ensuring users experience fewer drops and interruptions.

Another significant feature of the Linksys RDI-36-H HCI-36-H is its comprehensive security features that include WPA2 encryption, ensuring that users’ data is protected from unauthorized access. Furthermore, the device offers parental controls that allow users to manage internet access for specific devices, making it easier to ensure safe browsing for children.

The router also features Gigabit Ethernet ports, providing ultra-fast wired connections for devices such as gaming consoles, smart TVs, and computers. This ensures optimal performance for bandwidth-heavy activities, reducing latency and enhancing overall user experience.

Setup and management of the Linksys RDI-36-H HCI-36-H is facilitated through a user-friendly web interface and mobile app, allowing users to customize settings and monitor network activity conveniently.

In summary, the Linksys RDI-36-H HCI-36-H is a feature-rich router that combines dual-band technology, MU-MIMO, Beamforming, and robust security features to meet the demands of modern users. Its ability to support multiple devices seamlessly while providing fast, reliable connections makes it an excellent choice for anyone looking to enhance their home or small office network.