First Alert fire and burglary partitioned security systems with scheduleing About The Keypads

Page 10

About The Keypads

General

IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.

Your keypads allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) which shows the nature and location of all occurrences. Keypad display back lighting is programmable to always stay on or to light only when a key is pressed, then turn off a few minutes later.

The keypads also feature a built-in sounder which will sound during alarms and troubles. It will also "beep" during certain system functions, such as during entry/exit delay times, during CHIME mode, and when depressing keys to arm and disarm the system (to acknowledge the key press). These sounds can be optionally suppressed in some of your keypads (so as not to disturb other users of the system). Ask your installer if this has been done.

The Alpha Keypad

Alpha keypads feature a 2-line, 32 character alphanumeric Liquid Crystal Display (LCD) which can display system messages in friendly English. Abbreviated user's instructions can also be displayed (see Self Help paragraph in the SYSTEM OVERVIEW section). These keypads can also be programmed with custom zone descriptors.

– 10 –

Image 10
Contents $&&$&% Table of Contents Trouble Conditions General System OverviewPartitioned System Fire Protection System Overview cont’dZones Burglary ProtectionMemory of Alarm AlarmsSpeed Key Macros Device Timers Using SchedulesTo Access Another Partition Goto Command Master Keypad Operation Self-Help FeaturePhone Access & Voice Response Capability To view the abbreviated instructionsSystem Overview cont’d About The Keypads Alpha KeypadFunctions Of The Keypad Functions Of The Keypad cont’d Functions Of The Keypad cont’d Entry/Exit Delays General InformationDuress Code Security Codes & Authority LevelsQuick Arming Security Codes & Authority Levels cont’d Authority LevelsGeneral Rules on Authority Levels and Changes To view your authority level and system capabilitiesTo Exit User Edit Mode To Add a UserRF Button ? Limited Use User#84 Command To Change a Users CodeTo Delete a User Global Arming Accessing Other PartitionsTo Access Another Partition To Goto another partitionAccessing Other Partitions cont’d Fault 002 Loading Dock Window Common Lobby Operation Codes with Global Arming How User Codes Affect the Common LobbyCodes with Non-Global Arming Other Methods of Arming/Disarming Typical fault display Using Ready KeyTo show faulted zones Checking For Open ZonesDisplaying All Zone Descriptors Bypassing Protection Zones Using Bypass KeyTo bypass zones, the system must be disarmed first Quick Bypass To use the Quick Bypass featureBypassing Protection Zones cont’d Displaying Bypassed ZonesUsing the 3 Stay key Arming Perimeter OnlyWith Entry Delay OFF Using Instant KeyUsing the 2 Away Key Arming All ProtectionUsing Maximum Key Using the 1 OFF Key Disarming And Silencing AlarmsTo disarm the system and silence burglary or fire alarms Arming Using The KeyswitchDisarming Chime Mode Using KeyViewing Central Station Messages Using Panic Keys Panic KeysSpeed Key Macros DefiningSpeed Key Macros cont’d ExecutingAccess Door Control Using #70 Relay Menu Mode To activate relays using a telephone and 4285 or 4286 VIPUsing #70 Relay Menu Mode cont’d To Exit Enter 00 NOWTo delay the closing time Using SchedulesDelaying the Closing Time Temporary Open/Close SchedulesProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules Using Schedules cont’d Days ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modeProgramming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ? To Display The Event Log Event Log ProceduresSelect the partition Event Logging Procedures To Exit the Event LogTesting The System Using Test KeyTesting The System cont’d Testing Your SystemCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Fire Display Lock Fire Alarm System cont’dFire Drill Test Code + # + Fire Alarm System cont’d Trouble Conditions Typical Trouble DisplaysCall for Service Immediately Trouble Conditions cont’dPower Failure Servicing InformationRecommendations For Proper Protection Recommendations For Smoke And Heat DetectorsRecommendations For Proper Protection cont’d Addition, we recommend the followingRecommendations For Proper Intrusion Protection Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Function Procedure Comments Quick Guide To System FunctionsQuick Guide To System Functions cont’d Summary Of Audible Notification Alpha Display KeypadsGlossary Federal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Limitations of this Alarm System Index AwayLsens ¬19¢Ll

fire and burglary partitioned security systems with scheduleing specifications

First Alert is a trusted name in safety and security, consistently providing innovative solutions to protect homes and businesses. Their fire and burglary partitioned security systems are specifically designed to ensure comprehensive coverage against threats, offering users peace of mind. These systems utilize advanced technologies to deliver unparalleled performance.

One of the main features of First Alert fire and burglary security systems is the partitioning capability. This allows users to divide their property into separate zones or areas, each with its own security settings. For instance, during daytime, homeowners can enable security solely in specific areas, such as bedrooms and home offices, while keeping other regions like living rooms and kitchens unmonitored. This flexibility helps conserve energy and reduces false alarms, making the system more efficient.

Scheduling is another critical characteristic of First Alert systems. Users have the ability to create customized schedules for when the security system should be active or inactive. For example, a homeowner may set the system to turn on automatically in the evenings when they are away and to remain off during weekends when they are home. This programmable feature enhances user convenience and allows for tailored security solutions that fit individual lifestyles.

First Alert’s systems incorporate the latest technological advancements, including integrated smoke and carbon monoxide detectors. This multidimensional approach means that not only does the user benefit from burglary prevention, but they are also safeguarded against potential fire hazards. The sensors can communicate directly with a central hub, sending real-time alerts to homeowners’ smartphones in case of emergencies.

Moreover, First Alert integrates smart home compatibility, allowing users to connect their security system with various smart devices. This integration means homeowners can monitor their property remotely, receive notifications, and even take immediate action through mobile applications.

Overall, First Alert fire and burglary partitioned security systems stand out due to their unique combination of flexibility, scheduling capabilities, and advanced technology. These features are designed not just to deter potential threats but also to enhance the overall safety and security experience for users. With First Alert, homeowners can enjoy the reassurance that they are taking proactive steps to protect what matters most.