WARNING!

THE LIMITATIONS OF THIS ALARM SYSTEM

While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example:

Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device.

Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.

Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path.

A user may not be able to reach a panic or emergency button quickly enough.

While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending upon the nature of the fire and/or the locations of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death.

Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection performance can decrease.

– 76 –

Image 76
Contents $&&$&% Table of Contents Trouble Conditions General System OverviewPartitioned System System Overview cont’d ZonesFire Protection Burglary ProtectionMemory of Alarm AlarmsSpeed Key Macros Device Timers Using SchedulesTo Access Another Partition Goto Command Self-Help Feature Phone Access & Voice Response CapabilityMaster Keypad Operation To view the abbreviated instructionsSystem Overview cont’d About The Keypads Alpha KeypadFunctions Of The Keypad Functions Of The Keypad cont’d Functions Of The Keypad cont’d Entry/Exit Delays General InformationDuress Code Security Codes & Authority LevelsQuick Arming Security Codes & Authority Levels cont’d Authority LevelsGeneral Rules on Authority Levels and Changes To view your authority level and system capabilitiesTo Exit User Edit Mode To Add a UserRF Button ? Limited Use User#84 Command To Change a Users CodeTo Delete a User Accessing Other Partitions To Access Another PartitionGlobal Arming To Goto another partitionAccessing Other Partitions cont’d Fault 002 Loading Dock Window Common Lobby Operation Codes with Global Arming How User Codes Affect the Common LobbyCodes with Non-Global Arming Other Methods of Arming/Disarming Using Ready Key To show faulted zonesTypical fault display Checking For Open ZonesDisplaying All Zone Descriptors Bypassing Protection Zones Using Bypass KeyTo bypass zones, the system must be disarmed first To use the Quick Bypass feature Bypassing Protection Zones cont’dQuick Bypass Displaying Bypassed ZonesUsing the 3 Stay key Arming Perimeter OnlyWith Entry Delay OFF Using Instant KeyUsing the 2 Away Key Arming All ProtectionUsing Maximum Key Using the 1 OFF Key Disarming And Silencing AlarmsTo disarm the system and silence burglary or fire alarms Arming Using The KeyswitchDisarming Chime Mode Using KeyViewing Central Station Messages Using Panic Keys Panic KeysSpeed Key Macros DefiningSpeed Key Macros cont’d ExecutingAccess Door Control Using #70 Relay Menu Mode To activate relays using a telephone and 4285 or 4286 VIPUsing #70 Relay Menu Mode cont’d To Exit Enter 00 NOWUsing Schedules Delaying the Closing TimeTo delay the closing time Temporary Open/Close SchedulesProgramming Temporary Schedules Using Schedules cont’dTo program temporary schedules Using Schedules cont’d Days ? Mtwtfss HIT 0-7 X Programming Device Timers To enter the device timer menu modeProgramming Device Timers cont’d DAYS? Mtwtfss HIT 0-7 X Permanent ? To Display The Event Log Event Log ProceduresSelect the partition Event Logging Procedures To Exit the Event LogTesting The System Using Test KeyTesting The System cont’d Testing Your SystemCase Of Fire Alarm Fire Alarm SystemSilencing a Fire Alarm Fire Display Lock Fire Alarm System cont’dFire Drill Test Code + # + Fire Alarm System cont’d Trouble Conditions Typical Trouble DisplaysCall for Service Immediately Trouble Conditions cont’dPower Failure Servicing InformationRecommendations For Proper Protection Recommendations For Smoke And Heat DetectorsRecommendations For Proper Protection cont’d Addition, we recommend the followingRecommendations For Proper Intrusion Protection Emergency Evacuation Maintaining Your System Replacing Batteries in Wireless SensorsTaking Care of Your System Maintaining Your System cont’d Silencing Low Battery Warning Tones at the KeypadRoutine Care Function Procedure Comments Quick Guide To System FunctionsQuick Guide To System Functions cont’d Summary Of Audible Notification Alpha Display KeypadsGlossary Federal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 Notice Canadian Department of Communications DOC Statement Limitations of this Alarm System Limitations of this Alarm System Index AwayLsens ¬19¢Ll

fire and burglary partitioned security systems with scheduleing specifications

First Alert is a trusted name in safety and security, consistently providing innovative solutions to protect homes and businesses. Their fire and burglary partitioned security systems are specifically designed to ensure comprehensive coverage against threats, offering users peace of mind. These systems utilize advanced technologies to deliver unparalleled performance.

One of the main features of First Alert fire and burglary security systems is the partitioning capability. This allows users to divide their property into separate zones or areas, each with its own security settings. For instance, during daytime, homeowners can enable security solely in specific areas, such as bedrooms and home offices, while keeping other regions like living rooms and kitchens unmonitored. This flexibility helps conserve energy and reduces false alarms, making the system more efficient.

Scheduling is another critical characteristic of First Alert systems. Users have the ability to create customized schedules for when the security system should be active or inactive. For example, a homeowner may set the system to turn on automatically in the evenings when they are away and to remain off during weekends when they are home. This programmable feature enhances user convenience and allows for tailored security solutions that fit individual lifestyles.

First Alert’s systems incorporate the latest technological advancements, including integrated smoke and carbon monoxide detectors. This multidimensional approach means that not only does the user benefit from burglary prevention, but they are also safeguarded against potential fire hazards. The sensors can communicate directly with a central hub, sending real-time alerts to homeowners’ smartphones in case of emergencies.

Moreover, First Alert integrates smart home compatibility, allowing users to connect their security system with various smart devices. This integration means homeowners can monitor their property remotely, receive notifications, and even take immediate action through mobile applications.

Overall, First Alert fire and burglary partitioned security systems stand out due to their unique combination of flexibility, scheduling capabilities, and advanced technology. These features are designed not just to deter potential threats but also to enhance the overall safety and security experience for users. With First Alert, homeowners can enjoy the reassurance that they are taking proactive steps to protect what matters most.