Kenmore 153.337113, 153.33796 Installation Instructions contd, ALL AIR from Inside Buildings

Page 10

Installation Instructions (cont'd)

Combustion Air and Ventilation for Appliances Located in Unconfined Spaces

Unconfined Spac¢ is a space whosevolume is not less than 50 cubic feet per 1,000 Btu per hour of the aggregate input rating of all appliances instalhd in that space. Roomscommunicating directly with the space in which the appliances are installed, through openings not furnished with doors, are considereda part of the unconfined space

In unconfined spaces in buildings, infiltrationmay be adequate to provide air for combustion, ventilationand dilution of flue gases. However,in buildings of tight construction (for example, weather stripping, heavilyinsulated, caulked, vaporbarrier,etc.), additional air may need to be provided using the methods described in Combustion Air and Ventilation for Appliances Locatedin Confined Spaces,b.

Combustion Air and Ventilation for Appliances Located in Confined Spaces

Confined Spacc is a space whose volume is less than 50 cubic feet per 1,000 Btu per hour of the aggregate input ratingof all appliances installed in that space.

a. ALL AIR FROM INSIDE BUILDINGS:

(SeePage9 Figure1, and Figure2 below)

The confined space shall be provided with two permanent

openings communicating directlywith an additional room(s) of sufficient volume so that the combined volume of all

spaces meets the criteria for an unconfined space. The total input of all gas utilization equipment installed in the com- bined space shall be considered in making this determination. Each opening shall have a minimum free area of one square inch per 1,000 BTU per hour of the total input ratingofafi gas utilization equipment in the confined space, but not less than 100 square inches. One opening shall commence within

12 inches of the top and one commencing within 12 inches of the bottom of the enclosure.

1.When direcdycommunicating with the outdoors,each open- ing shall have a minimumflee area of I square inch per 4,000 BTU per hour of total input raring of all equipment in the enclosure. (See Figure3.)

2.When communicatingwith the outdoors through vertical ducts, each opening shall have a minimum free area of 1 sc!uareinch per 4,000 BTU per hour of total input ratingof all equipment in the enclosure.(SeeFigure 4.)

Figure 4 ]

3.When communicating with the outdoors through horizontal ducts, each opening shall have a minimum free area of 1 square inch per 2,000 BTU per hour of total input rating of all equipment in the endosure. (See Figure5.)

I Figure 2 ]

b. ALL AIR FROM OUTDOORS: (seeFigures3-5)

The confined space shall be provided with two permanent openings,one commencing within 12 inches of tee top and one commencing within 12 inches from the bottom of the enclosure. The openings shall communicate directly,or by

ducts, with the outdoorsor spaces (crawl or attic) that freely communicate with the outdoors.

I Figure 3 ]

[el,--

_i "

Ii f I....

4.When ductsare used, they shall be of the same cross-sectionalarea as the free area of the openings to which they connect. The minimum short side dimensionof rectangularair ducts shall not be lessthan 3 inches. (SeeFigure5.)

5.Louversand Grilles: In calculating free area, consideration

shall be given to the blocking effect of louvers, grilles or screensprotecting openings.Screens used shall not be smaller

than ¼ inch mesh. If the _ee area through a desi_ of louver or grille is known, it should be used in calculating the size opening recLuiredto provide the free area specified. If the designand free area is not known, it may be assumed that wood louverswill be 20-25 percent free areaand metallouvers and grilles will have 60-75 percent free area. Louversand grillesshall be fixed in the open position or interlocked with the .equipment so. that they are opened automatically during equipmentoperation.

6.Special Conditions Created by Mechanical Exhaustingor Fireplaces:Operation of exhaust fans, ventilation systems, clothes dryersor fireplacesmay create conditions requiring

specialattention to avoid unsatisfactoryoperationof installed gasutilizationequipment.

1o

Image 10
Contents AN Odorant is Added to the GAS Used by this Water Heater For Your SafetyNot for USE What to do if YOU Smell GASSafety Precautions Installations in Areas Where Flammable LIQSafety Precautions Hotter Water can Scald Water heaters areExVemelyflmmae d mqse. To preventthe pem Improper operation, explosionor asphyxiationContents 59½ Product SpecificationsCustomer Responsibilities 58¼Materials Needed Materials and Basic Tools NeededBasic Tools If the main gasline--all Gasappliancesis Installation InstructionsRemoving the Old Water Heater Used, lso shut doffthe gasat eachappliance LeaveallWater Heaters Eventually Leak Installation Installation Instructions contdFacts to Consider About Location ALL AIR from Inside Buildings Installation Instructions contdALL AIR from Outdoors seeFigures3-5 Water Piping HOVrERWATERCAN SCALDWater. heatersareintendedtoAt the time of manufacture this water heater was provided DischargePipeHeaithriskor Filling the Water HeaterVenting Sionor asphyxonGas Piping Sediment Trap GAS Piping with Flexible ConnectorUse pipejoint compoundor teflon tape marked as beingJ ContaminentsInthe Ips rmesn/came OperonInstallation Checklist Lighting Operating InstructionsCheck for Leaks Not Force Operating Instructions contdWhattodoif Yousmellgas ForceSonunattendedn a bathtubor shower Temperature RegulationOperating Instructions contd Hotter Water can Scald Water heatersare intendedtoBurner Cleaning Service and AdjustmentTank Sediment Cleaning Burner InspectionWhan chedd the tempereteretammrer vae opera Service and Adjustment contdGas Control Valve & Burner Assembly Replacement Information Pmper dame beaue thewaternW beexm.y hotHousekeeping Follow instructions in the Filling The Water Heater sectionThermal Expansion Troubleshooting GuideStart Up Conditions Strange SoundsSmelly Water Start Up Conditions contdCondensationsmokeiodor AIR in HOT Water FaucetsNot Enough or no HOT Water Troubleshooting Guide contdHigh Temperature Shut OFF System Water is TOO HOTLeakage Checkpoints Never use this water terPage Page Page Power Miser TM 9 GAS Water Heaters Model Numbers Parts Order ListModel Ratin Platet Parts Order List contdChick Power Miser TM 9 GAS Water Heaters Model Number Parts Order List contd KEY ManualLightingpilot Leaksinpipesorfittings Em-4ee4ees

153.337113, 153.337462, 153.337513, 153.337762, 153.337413 specifications

The Kenmore series 153.337662, 153.337562, 153.337462, 153.337113, and 153.33796 represents a range of high-performance appliances that deliver exceptional functionality and convenience to homeowners. Renowned for their energy efficiency and advanced technologies, these models are designed to cater to various household needs while maintaining a focus on user-friendly operation.

One of the hallmark features of the Kenmore 153 series is its innovative Smart Technology. This technology enables users to connect their appliances to a home network, allowing for remote control and monitoring through smartphone apps. With this capability, users can adjust settings, receive alerts, and even troubleshoot issues from virtually anywhere, providing enhanced convenience and peace of mind.

In addition to Smart Technology, the Kenmore 153 series is equipped with advanced sensors that optimize performance. For example, the models feature moisture sensing capabilities that detect the dampness of clothes and automatically adjust drying time accordingly. This not only saves energy but also protects fabrics from over-drying, thus extending the life of garments.

Energy efficiency is another critical characteristic of the Kenmore 153 series. These appliances are designed with eco-friendly functionalities that minimize energy consumption without compromising performance. They often come with Energy Star certification, allowing users to enjoy significant savings on utility bills while contributing to a more sustainable environment.

The Kenmore 153 series also boasts a sleek and modern design that integrates seamlessly into any home decor. With user-friendly control panels, bright displays, and customizable settings, these appliances are as functional as they are aesthetically pleasing. Whether it's a refrigerator, washing machine, or dryer, each model is built with durability in mind, ensuring they withstand the rigors of daily use.

Furthermore, the Kenmore 153 series emphasizes easy maintenance and cleaning. Many models feature self-cleaning options and removable components that simplify the upkeep process, allowing users to spend less time on chores and more time enjoying their homes.

In summary, the Kenmore 153.337662, 153.337562, 153.337462, 153.337113, and 153.33796 models exemplify a commitment to quality, efficiency, and innovative technology. With features that enhance usability and performance, these appliances stand out in the marketplace, making them a popular choice for modern households looking to elevate their everyday living experiences.