Safety Precautions
AWARNING
Improper installation, adjustment, alteration, service or I maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manu- al for assistance or consult your local Sears Service
Center for further information. | I |
AWARNING
WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY: This water heater is equipped for one type gas only. Check the model rating plate near the gas control valve for the correct gas. DO NOT USE THIS WATER HEATER WITH ANY GAS OTHER THAN THE ONE
SHOWN ON THE MODEL RATING PLATE. Failure to
use the €orrect gas can cause problems which can result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or doubts consult your gas supplier or local utility.
4WARNING
INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ-
UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGE, AHD UTILITY AREAS, ETC): Flammable liquids (such as gasoline, solvents, propane (LP) or butane, etc.), all of which emit flammable vapors, may be improperly stored or used in such areas. The gas water heater pilot tight or main burner can ignite such vapors. The resulting flashback and fire can cause death or serious burns to anyone in the area, _ well as
property d_magn, | i |
If installation in such areas is your only option, then the | |
installation must be accomplished in a way that the pilot flame and main burner flame are elevated from the floor
at least 18 inches. While this may reduce the chances of !flammable vapors from a floor spill being ignited, gasoline iand other flammable substancesshould never be stored or
used in the same room or erda containing a gas water heater or other open flame or spark producing appliance. NOTE: Flammable vapors may be drawn by air currents from other areas of the structure to the appliance.
AWARNING
If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that €om- bustion and ventilation air be taken from outside these areas, Refer to the "Facts to Consider About the Location" section of this manual and also the latest edi- tion of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for specifics provided concernin air required,
Afire can start if combustible materials such as cloth,ng,
cleaning ma_, or flamm_de liquids are placed against I
or next to the water heater. | [ |
AWARNING
At the time of manufacture this water heater was provid- ed with a combination temperature-pressures relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed
equipment or materials, as meeting the requirements for Relief Valves and Automatvc Gas Shutoff Devices for
Hot Water Supply Systems, and the latest edition of
ANSI Z21.22 and the code requirements of ASHE. If replaced, the valve must meat the requirements of local codes, but not lessthan a combination temperature and pressure relief valve certified as meeting the require- ments for Relief Valves and Automatic Gas Shutoff
Devices for Hot Water Supply Systems, ANSI Z21.22 by a nationally recognized testing laboratory that maintains
periodic inspection of production of listed equipment or materials.
The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (I 50 IbsJsq. in.) and a discharge capacity not less than the water heater input rate as shown on the model rating plate. (Electric heaters - watts divided by 1000 x 3415 equal BTU/Hr. rate.)
[Your local jurisdictional authority, while mandating the
use of a temperature-pressora relief valve complying with ANSI Z21.22 and ASME, may require a valve model different from the one furnished with the water heater.
Compliance with such local requirements must be satis- fied by the installer or end user of the water heater with a locally prescribed temperature-pressure relief valve installed in the designated opening in the water heater in place of the factory furnished valve.
For safe operation of the water heater, the relief valve must not be removed from it'sdesignated opening or plugged.
Tho temperatere-pressore relief valve must be installed directly into the fitting of the water heater designated for the relief valve. Position the valve downwlu_l and pro- vide tubing so that any discharge will exit only within 6 i inches above, or at any distance below the structural floor. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet, or use of more than four elbows can cause restriction and reduce the discharge
capacity of the valve.
No valve or other ebstxuction is to be placed between the relief valve and the tank. Do not connect tubing ditec_ to discharge drain unlessa 6" air gap is provided.
To prevent bodily injury, hazard to life, or property dam- age, tho relief valve must be allowed to discharge water in quantities should circumstances demand. If the dis- charge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.
The Discharge Pipe:
•Must not be smaller in size than the outlet pipe size of the valve, or have any reduclng couplings or other restrictions.
Must not be plugged or blocked.
Must be of"material listed fur hot water distribution. Must be installed so as to allow complete drainage of
both the temperature-pressure relief valve, and the discharge l_e,
Must terminate at an adequate drain,
Host not have any valve between the relief valve and tank.