ELECTRICAL

Electrical Connections

IMPORTANT: Do not use an extension cord to connect the water heater to an electrical outlet.

Before plugging in the water heater, always make sure:

The Voltage and frequency correspond to that specified on the water heater.

The electrical outlet has the proper overload fuse or breaker protection.

Unit is to connect to a 120VAC electrical supply outlet (extension cord is not allowed).

WARNING

Electric Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

The water heater and the outlet are properly grounded.

Installed in accordance with prevailing provisions of local codes, or in the absence of such, National Electric Code, ANSI/NFPS 70 current edition.

Completely fill the tank with water and check all connections for leaks. Open the nearest hot water faucet and let it run for three (3) minutes to purge the water lines of air and sediment and to ensure complete filling of the tank. The electrical power may then be turned on. Verify proper operation after servicing.

Solar Installation

If this water heater is used as a solar storage heater or as a backup for the solar system, the water supply temperatures to the water heater tank may be in excess of 120°F. A mixing valve or other temperature limiting valve must be installed in the water supply line to limit the supply temperature to 120°F.

NOTE: Solar water heating systems can often supply water with temperatures exceeding 180°F and may result in water heater malfunction.

Wiring Diagram

FIGURE 27.

Air Intake

Gas Control

Valve / Thermostat

Chamber Fan

 

Pressure

Switch

Igniter/Flame

Sense Connector

FV

Sensor

CAUTION:

LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.

Anode

Rod

Control Display

CAUTION:

DO NOT USE AN EXTENSION CORD TO CONNECT THE TRANSFORMER TO AN ELECTRICAL OUTLET.

Power Supply

Transformer

24

Image 24
Contents Gas Water Heater Safe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Hazard Breathing Hazard Carbon Monoxide GasTable of Contents Troubleshooting Chart Product Warranty Year Limited Warranty on Water HeaterCustomer Responsibilities Important Information About This Water HeaterProduct Specifications GAS PER Hour DIA. InchesMaterials and Basic Tools Needed Materials NeededTypical Installation GET to Know Your Water Heater GAS ModelsInstallation Checklist Important Information about this Water HeaterWater Heater Location Combustion Air Supply and VentilationInstallation Instructions Removing the Old Water HeaterLocation Requirements Site LocationCarbon Monoxide Poisoning Hazard Clearances and Accessibility High Altitude InstallationGas Pressure Testing GAS SupplyGas Requirements Gas PipingGas Pipe Capacity Table Combustion AIR & Ventilation Unconfined SpaceConfined Space SquareLouvers and Grilles All Air from the BuildingAll Air from Outdoors Draft Hood Installation Vent Pipe SystemVent Connectors Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionTemperature & Pressure Relief Valve Relief Valve and Pipe InsulationSolar Installation ElectricalElectrical Connections Operating Your Water Heater Operating InstructionsWater Heater Operation Checking the DraftBurn Hazard Do not touch vent Doing so can result in burnsWater Temperature Regulation Burner FlamesEmergency Shut Down Hotter Cooler Service and Adjustment Routine Preventive MaintenanceDraining and Flushing Explosion HarzardMaintenance of Your Water Heater Replacement PartsRemoving the Burner from the Manifold/ Burner Assembly Removing the Manifold/Burner AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Manifold/Burner AssemblyRemoving and Replacing the Gas Control Valve/Thermostat Removing the Gas Control Valve/ThermostatReplacing the Gas Valve Troubleshooting Guide Start Up ConditionsService Operational ConditionsCondensation Smoke OdorLeakage Checkpoints Pressurized Combustion Chamber System Operational Checklist Troubleshooting ChartSIZZLING-RUMBLING Electronic Control Display Troubleshooting Control Display Status Problem Solution Control Display Status Problem Solution Troubleshooting Flowchart YESParts Order List Pressurized Combustion ChamberKey Parts Description 153.332620 153.332640 Page Get it fixed, at your home or ours MY-HOME1-800-469-4663
Related manuals
Manual 44 pages 3.4 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.