Kenmore 153.33262, 153.33264 manual Cleaning the Combustion Chamber and Air Diverter Assembly

Page 31

6.Reposition the manifold component block in the mani-fold door opening and secure it with the retainer clip.

7.See Replacing the Manifold/Burner Assembly.

External Inspection & Cleaning of the Air Intake Chamber Screen

1.At least twice annually inspect the air intake chamber screen (Figure 38) for any dust or debris that may have accumulated on the louvers. NOTE: If the water heater is located in an area that is subjected to lint and dirt, it may be necessary to check the air intake chamber screen

more frequently.

2. Use a vacuum cleaner with a hose attachment to remove any dust or debris that may have accumulated on the screen.

Air Intake Chamber

Screen

FIGURE 38.

Cleaning the Combustion Chamber and Air Diverter Assembly

1.Follow procedure outlined in “Removing the Manifold/Burner Assembly”.

2.Use a vacuum cleaner/shop vac to remove all loose debris in the combustion chamber (Figure 39). Use compressed air to clear any dust or debris that may have accumulated on the air diverter assembly.

Air Diverter

Combustion

Assembly

Chamber

Manifold

 

Door Gasket

 

FIGURE 39.

 

3.Reassemble following the procedure under “Replacing the Manifold/Burner Assembly”

Replacing the Manifold/Burner Assembly

WARNING

Explosion Hazard

Remove any fiberglass between gasket and combustion chamber.

Replace viewport if glass is missing or damaged.

Replace two piece wire connector if missing or removed.

Replace door gasket if damaged.

Tighten both manifold door screws securely.

Failure to follow these instructions can result in death, explosion, or fire.

1.Check the door gasket for damage or imbedded debris prior to installation.

2.Inspect the view port for damage and replace as required.

3.Insert the manifold/burner assembly into the burner compartment making sure that the tip of the manifold tube engages in the slot of the bracket inside the combustion chamber (Figure 40).

4.Inspect the door gasket and make sure there is no fiberglass insulation between the gasket and the

combustion chamber.

5.Replace the two screws, which secure the manifold/ burner assembly door to the combustion chamber and tighten securely. Once the manifold/burner assembly door is tightened, visually inspect the door gasket between the manifold/burner assembly door and the combustion chamber for spaces or gaps that would prevent a seal. IMPORTANT: Do not operate the water heater if the door gasket does not create a seal between the manifold door and the combustion chamber.

6.During the following procedure, do not cross-thread or apply any thread sealant to any of the fittings listed below. First, reconnect the manifold tubing to the gas control valve/ thermostat.

7.Reconnect the flame sense/hot surface igniter wire to the gas control valve/thermostat (Figure 35).

8.Turn gas supply on and refer to the Lighting Instructions.

9.With the burner lit, check the gas control valve/thermostat supply line, two piece wire connector, and manifold tube connections for leaks. Check for leaks by brushing on an approved noncorrosive leak detection solution. IMPORTANT:

Do Not splash solution onto the electrical connections. Bubbles forming indicate a leak. Correct any leak found. All leaks must be fixed immediately.

31

Image 31
Contents Gas Water Heater Safety Precautions Safe INSTALLATION, USE and ServiceBreathing Hazard Carbon Monoxide Gas Fire or Explosion HazardTable of Contents Troubleshooting Chart Year Limited Warranty on Water Heater Product WarrantyImportant Information About This Water Heater Customer ResponsibilitiesGAS PER Hour DIA. Inches Product SpecificationsMaterials Needed Materials and Basic Tools NeededGET to Know Your Water Heater GAS Models Typical InstallationCombustion Air Supply and Ventilation Installation ChecklistImportant Information about this Water Heater Water Heater LocationRemoving the Old Water Heater Installation InstructionsSite Location Location RequirementsCarbon Monoxide Poisoning Hazard High Altitude Installation Clearances and AccessibilityGas Piping Gas Pressure TestingGAS Supply Gas RequirementsGas Pipe Capacity Table Square Combustion AIR & VentilationUnconfined Space Confined SpaceAll Air from the Building Louvers and GrillesAll Air from Outdoors Vent Pipe System Draft Hood InstallationVertical Exhaust Gas Vent Vent ConnectorsVent Pipe Size Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveRelief Valve and Pipe Insulation Temperature & Pressure Relief ValveElectrical Solar InstallationElectrical Connections Operating Instructions Operating Your Water HeaterDo not touch vent Doing so can result in burns Water Heater OperationChecking the Draft Burn HazardBurner Flames Water Temperature RegulationEmergency Shut Down Hotter Cooler Explosion Harzard Service and AdjustmentRoutine Preventive Maintenance Draining and FlushingRemoving the Manifold/Burner Assembly Maintenance of Your Water HeaterReplacement Parts Removing the Burner from the Manifold/ Burner AssemblyReplacing the Manifold/Burner Assembly Cleaning the Combustion Chamber and Air Diverter AssemblyRemoving the Gas Control Valve/Thermostat Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Start Up Conditions Troubleshooting GuideSmoke Odor ServiceOperational Conditions CondensationLeakage Checkpoints Troubleshooting Chart Pressurized Combustion Chamber System Operational ChecklistSIZZLING-RUMBLING Electronic Control Display Troubleshooting Control Display Status Problem Solution Control Display Status Problem Solution YES Troubleshooting FlowchartPressurized Combustion Chamber Parts Order ListKey Parts Description 153.332620 153.332640 Page MY-HOME1-800-469-4663 Get it fixed, at your home or ours
Related manuals
Manual 44 pages 3.4 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.