Kenmore 153.33264, 153.33262 manual Control Display Status Problem Solution

Page 40

 

CONTROL DISPLAY STATUS

PROBLEM

SOLUTION

 

 

 

 

9.

“FV-SENSE” Flashing

 

4. System must be manually reset by entering a

 

(Continued from previous page)

 

special FVS reset sequence into the Electronic

 

 

Control Display. See Electronic Control

 

 

 

 

 

 

Display - FV - Sense Reset Sequence in

 

 

 

the Kenmore PCC Water Heater Service

 

 

 

Handbook.

 

 

 

 

10.

“LDO-SW”, “OPEN”, and “CLEAN SCREEN”

The air pressure switch contacts

1. Clean the screen on the combustion air

 

Flashing

remain open longer than 5

intake chamber, retest.

 

 

seconds after the combustion fan

2. If the problem persists: Cycle power to the

 

 

is energized.

 

 

water heater “OFF” and “ON” to reset.

 

 

 

 

 

 

 

11.

“FV-SENSE” and “OPEN” Flashing

 

1. Check all wiring to the flammable vapor

Flammable Vapor Sensor is open

sensor.

 

 

 

2. Remove the connectors from the

 

 

 

flammable vapor sensor and measure

 

 

 

the resistance of the sensor with an

 

 

 

ohmmeter.

 

 

 

A. If the reading taken is more than

 

 

 

1.7 million ohms, replace the

 

 

 

flammable vapor sensor.

 

 

 

B. If the reading taken is less than 1.7

 

 

 

million ohms, and the wiring from

 

 

 

the control to the sensor is good,

 

 

 

replace the lower control.

 

 

 

 

 

 

 

1. Check all wiring to the flammable vapor

12.

“FV-SENSE” and “SHORT” Flashing

Flammable Vapor Sensor is

sensor.

 

 

shorted

2. Remove the connectors from the

 

 

 

 

 

 

flammable vapor sensor and measure

 

 

 

the resistance of the sensor with an

 

 

 

ohmmeter.

 

 

 

A. If the reading taken is less than

 

 

 

2000 ohms, replace the flammable

 

 

 

vapor sensor.

 

 

 

B. If the reading taken is more than

 

 

 

2000 ohms, and the wiring from the

 

 

 

control to the sensor is good,

 

 

 

replace the lower control.

 

 

 

 

13.

“THMSTR” and “OPEN” Flashing

 

1. Turn power off for 10 to 20 seconds then

The self-diagnostic test has

on again to clear this error code.

 

 

detected the temperature sensor

2. This part of the control cannot be

 

 

(thermistor) inside the immersion

 

 

probe is open.

replaced or serviced. If the error code

 

 

 

cannot be cleared, the lower control must

 

 

 

be replaced.

 

 

 

 

14.

“THMSTR” and “SHORT” Flashing

The self-diagnostic test has

1. Turn power off for 10 to 20 seconds then

on again to clear this error code.

 

 

detected the temperature sensor

2. This part of the control cannot be

 

 

(thermistor) inside the immersion

 

 

probe is shorted.

replaced or serviced. If the error code

 

 

 

cannot be cleared, the lower control must

 

 

 

be replaced.

 

 

 

 

15.

All Segments Flashing

The self-diagnostic check has

1. Press and release each of the

temperature adjustment buttons. If the

 

 

detected one or both of the

above action does not clear the error, the

 

 

temperature adjustment buttons

control will continue to regulate the water

 

 

are stuck.

temperature at the last setting. However,

 

 

 

settings will no longer be adjustable – the

 

 

 

upper control should be replaced.

 

 

 

 

 

 

 

1. Check the wire that runs from the power

16.

“P-ANODE” and “OPEN” Flashing

No current to Power Anode.

anode to the upper control. Check the

 

 

 

wire for damage, and to ensure that the

 

 

 

connectors are fully seated into the

 

 

 

mating connectors on both ends.

 

 

 

2. Check that the tank is full of water. Never

 

 

 

use this water heater unless it is

 

 

 

completely full of water. To prevent

 

 

 

damage to the tank, the tank must be

 

 

 

filled with water. Water must flow from

 

 

 

the hot water faucet before turning “ON”

 

 

 

gas to the water heater.

 

 

 

3. Cycle power to the water heater “OFF” and

 

 

 

“ON” to reset.

 

 

 

17.

“P-ANODE” Flashing

 

1. Turn the power off for 10 to 20 seconds

Power Anode circuit failure.

then on again to clear the error code.

 

 

 

2. If the error code persists or cannot be

 

 

 

cleared, replace the upper control.

 

 

 

 

40

Image 40
Contents Gas Water Heater Safe INSTALLATION, USE and Service Safety PrecautionsFire or Explosion Hazard Breathing Hazard Carbon Monoxide GasTable of Contents Troubleshooting Chart Product Warranty Year Limited Warranty on Water HeaterCustomer Responsibilities Important Information About This Water HeaterProduct Specifications GAS PER Hour DIA. InchesMaterials and Basic Tools Needed Materials NeededTypical Installation GET to Know Your Water Heater GAS ModelsInstallation Checklist Important Information about this Water HeaterWater Heater Location Combustion Air Supply and VentilationInstallation Instructions Removing the Old Water HeaterSite Location Location RequirementsCarbon Monoxide Poisoning Hazard Clearances and Accessibility High Altitude InstallationGas Pressure Testing GAS SupplyGas Requirements Gas PipingGas Pipe Capacity Table Combustion AIR & Ventilation Unconfined SpaceConfined Space SquareAll Air from the Building Louvers and GrillesAll Air from Outdoors Draft Hood Installation Vent Pipe SystemVent Connectors Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingTemperature and Pressure Relief Valve Closed System/Thermal ExpansionTemperature & Pressure Relief Valve Relief Valve and Pipe InsulationElectrical Solar InstallationElectrical Connections Operating Your Water Heater Operating InstructionsWater Heater Operation Checking the DraftBurn Hazard Do not touch vent Doing so can result in burnsBurner Flames Water Temperature RegulationEmergency Shut Down Hotter Cooler Service and Adjustment Routine Preventive MaintenanceDraining and Flushing Explosion HarzardMaintenance of Your Water Heater Replacement PartsRemoving the Burner from the Manifold/ Burner Assembly Removing the Manifold/Burner AssemblyCleaning the Combustion Chamber and Air Diverter Assembly Replacing the Manifold/Burner AssemblyRemoving the Gas Control Valve/Thermostat Removing and Replacing the Gas Control Valve/ThermostatReplacing the Gas Valve Troubleshooting Guide Start Up ConditionsService Operational ConditionsCondensation Smoke OdorLeakage Checkpoints Pressurized Combustion Chamber System Operational Checklist Troubleshooting ChartSIZZLING-RUMBLING Electronic Control Display Troubleshooting Control Display Status Problem Solution Control Display Status Problem Solution Troubleshooting Flowchart YESPressurized Combustion Chamber Parts Order ListKey Parts Description 153.332620 153.332640 Page Get it fixed, at your home or ours MY-HOME1-800-469-4663
Related manuals
Manual 44 pages 3.4 Kb

153.33262, 153.33264 specifications

The Kenmore 153.33262 and 153.33264 are highly versatile and efficient portable air conditioners designed to provide optimal cooling solutions for indoor spaces. These models stand out in their class due to their advanced features, technologies, and user-friendly characteristics, making them suitable for a variety of environments, from small apartments to large rooms.

One of the primary features of both the Kenmore 153.33262 and 153.33264 is their high cooling capacity. With powerful BTUs, they can effectively cool spaces up to a specified square footage. This capability ensures that users can maintain a comfortable indoor climate even during the hottest summer months. Their energy efficiency is another notable aspect, allowing homeowners to enjoy cooler air without incurring exorbitant energy bills.

The two models are equipped with various modes of operation, including cooling, fan, and dehumidifying modes. This multifunctionality allows users to customize their comfort based on prevailing weather conditions. For instance, the dehumidifying mode effectively reduces excess moisture in the air, creating a more comfortable environment, particularly in humid regions.

Both air conditioners come with a user-friendly digital interface that features an easy-to-read LED display. The interface allows for straightforward adjustments to the temperature, fan speed, and operating modes. Furthermore, remote control functionality enhances convenience, enabling users to change settings from across the room.

In terms of technology, these models incorporate a self-evaporating system that minimizes the need for manual water drainage. This feature is particularly advantageous for users who prefer low-maintenance options. Additionally, both units feature a washable air filter, designed to capture dust and allergens, improving air quality and ensuring that the units operate efficiently.

Portability is another significant characteristic of the Kenmore 153.33262 and 153.33264. Built-in caster wheels and side handles allow for easy movement from room to room, making them ideal for temporary cooling needs. The easy installation process and included window exhaust kit mean users can set up the units quickly without requiring professional assistance.

In conclusion, the Kenmore 153.33262 and 153.33264 portable air conditioners offer a robust combination of high cooling performance, energy efficiency, and user-friendly features. Their advanced technologies and versatile functionalities make them an ideal choice for those seeking effective indoor air conditioning solutions.