Kenmore 78189, 70129, 70089, 78079 owner manual Controls, Touch Control Panel

Page 20

Controls

Figure 37. Touch Control Panel

m

I

I

m

B

B

aid

/oFF-)i 1LOWiI"'°"s,vEOFo. .L*^ IV"}

COOL PLUS _ ____

MODESET

I

EXHAUST CLOSEO

See Figure 37. Kenmore room air conditioners have an electronic touch control panel located across top front of unit. Functions and operation of each control are explained below.

Touch Panel Controls

To operate touch controls, press control pad until indicator above pad lights (does not apply to OFF or

V I A pads).

OFF--Turns air conditioner off.

SMART SET--Places air conditioner in "smart" cooling

mode. SMART SET uses computer logic to cool area quickly and quietly. When unit first turns on, fan starts at high speed. As room temperature nears set temperature, fan automatically switches to medium speed, then low speed. When room cools to set temperature, fan continues to run at low speed and compressor cycles on and off to maintain room temperature.

LOW COOL--Fan operates continuously at low speed, except in power saver mode. If unit is in a cooling mode, compressor cycles on and off as required to maintain set temperature. Select this setting for quietest operation.

MED COOL--Fan operates continuously at medium speed, except in power saver mode. If unit is in a cooling mode, compressor cycles on and off as required to maintain set temperature. Select this setting for reduced air circulation and quieter operation.

HIGH COOL--Fan operates continuously at high speed, except in power saver mode. If unit is in a cooling mode, compressor cycles on and off as required to maintain set temperature. Use this setting for maximum air circulation and faster cool-down during initial start up.

POWER SAVER PLUS--Places air conditioner in energy-saving mode. Energy-saving mode works in conjunction with SMART SET mode and low, medium, or high fan speeds. In energy-saving mode, air conditioner maintains room temperature within 1.5 ° F of programmed temperature setting. When POWER SAVER PLUS is selected, fan cycles on and off with compressor, instead of running continuously as in other

modes. During compressor off cycle, fan automatically turns on for about 2 minutes at 5 minute intervals to

sample room air temperature. If room temperature is within 1.5°F of programmed temperature, time between sampling increases to a maximum of 15 minutes.

If room temperature is more than 1,5°F above programmed setting, fan continues to run and compressor cycles on to cool room. When room cools to set temperature, compressor and fan turn off and

time between air sampling cycles decreases to a minimum of 5 minutes.

FAN ONLY--Fan operates continuously at set speed (high, medium, or tow) and compressor remains off.. Use this setting to circulate air without cooling and, with VENT CONTROL in EXHAUST position, to vent room of stale air, odors, smoke, etc. Displays actual room temperature.

VIA --Usedto decrease ("down" arrow) or increase ("up"arrow) set temperature. When used with DELAY

START function, arrow keys adjust delay start or stop time.

DELAY START--Allows programming a delay of up to

24hours before air conditioner starts, or programming air conditioner to automatically stop after up to 24 hours of operation. Automatic start or stop is programmable from 1 hour (minimum) up to 24 hours (maximum), in one hour increments. See Operation Instructions for information on programming air conditioner for delay start or automatic stop.

Vent Control

Vent control lever, located on lower dght corner of front

panel, controls a damper that recirculates or exhausts room air.

With control in CLOSED position, damper is closed and air in area being cooled is recirculated through air conditioner, filtered, cooled, and returned to room. No air is exhausted (vented) outside.

NOTE: For maximum efficiency and cooling, vent control should remain closed any time air conditioner is cooling.

With control in EXHAUST position, damper is open.

When open, room air is exhausted (vented) outside. Usa exhaust position to remove stale or smoky air.

NOTE: To conserve energy, use FAN ONLY position with EXHAUST feature.

Brightness Adjust Feature (some models) Display brightness can be changed using V I A pad.

To decrease brightness, simultaneously press and hold OFF pad with "down" arrow. To increase brightness, press and hold OFF pad with =up" arrow key.

Image 20
Contents OwnersManual Model Numbers 78079, 70089, 70129Contents WarrantySafety. Instructions IdangeriShown removed for easier component identification Parts and Feature IdentificationModel Identification Sizing Instructions Installation Installing Room Air ConditionersVoltage Check with a qualified electrician if you are notInstallation Window Installation Kit PartsInstallation Support Bracket Assembly Icautioni Installing Seal Strip Window seal strip Outdoor sash Window Installation--12000, and 18000 Btu Units Models 70129 Typical Double-Hung Window Window sill Applying Window Sill GasketAttaching Adjusting Foot to Outside Support Attaching Outside Supports to Outer Case Outer caseAdjusting Outer Case Slope Level Typical Cabinet Dimensions Slide-Out Chassis Outer Case Dimensions12000 Btu 18000 Btu 163,4inches 193Ainches 24¼ Inches General Instructions241/4inches Chamfering Walls That Exceed Outer Case Dimensions Side View Side louversControls Touch Control PanelOperating Instructions Before Turning Air Conditioner OnDelay Start Operation Operating InstructionsCare and Maintenance Normal Operating SoundsFrequency WeeklyRemoving Air Filter, Method One Air filterBase Pan Maintenance Evaporator Coil, Condenser Coil,Troubleshooting Accessories Assistance and ServiceService HomeCentrar

78079, 70089, 78189, 70129 specifications

The Kenmore brand has established itself as a trusted name in the appliance industry, and its line of vacuums, including the Kenmore 78189, 78079, 70129, and 70089, showcases the company's commitment to quality, performance, and innovative technology.

The Kenmore 78189 is renowned for its powerful suction and versatility. Equipped with a 2-motor system, it delivers exceptional cleaning performance on both carpets and hard floors. This model features an adjustable height setting, allowing it to accommodate various carpet types while effectively loosening dirt and debris. The sealed HEPA filtration system captures allergens, making it an excellent choice for households with allergy sufferers.

Similarly, the Kenmore 78079 model stands out due to its lightweight design and maneuverability. Despite its compact size, it boasts powerful suction capabilities. This model comes with a range of specialized tools, such as a pet hair attachment and a crevice tool, making it an ideal choice for pet owners. The efficient cyclone technology enhances airflow, preventing clogs and maintaining optimal performance.

The Kenmore 70129 model offers a blend of performance and ease of use. It is equipped with an advanced multi-cyclonic system that ensures consistent suction strength, while the dirt sensor technology alerts users when dirt remains to be picked up. This model also features an easy-to-empty dustbin, which simplifies maintenance.

Lastly, the Kenmore 70089 model is designed with convenience in mind. It features a retractable cord, making storage hassle-free. The model includes an array of onboard tools and a telescoping wand, enhancing its versatility for cleaning above-floor surfaces. Its lightweight design and ergonomic handle ensure a comfortable cleaning experience, reducing strain during extended use.

Overall, the Kenmore 78189, 78079, 70129, and 70089 models exemplify the brand's dedication to developing vacuums that combine powerful cleaning performance with user-friendly features. With advanced technologies like HEPA filtration, multi-cyclonic suction, and specialized attachments, these vacuum cleaners are designed to meet diverse cleaning needs, providing customers with reliable solutions for maintaining a spotless home. Whether tackling pet hair or household dust, these Kenmore models stand out in the competitive appliance market.