Kenmore 70089, 78189, 70129 Installation, Installing Room Air Conditioners, Voltage, To gas line

Page 6

Installation

Installing Room Air Conditioners

Proper installation of a room air conditioner helps ensure trouble-free operation, improper installation can result in problems ranging from excessive noise to property or equipment damage.

Installation requires some mechanical experience and aptitude. Depending upon installer's knowledge and skill, installation of a room air conditioner can take between 1 and 3 hours. Professional installation,

performed by authorized Sears technicians, is available. Contact a local Seers store or call 1-800-4-MY-HOME to

obtain an estimate and schedule an installation.

Before Beginning Any Installation

Carefully read all installation instructions. Make sure

each step or procedure is understood and any special considerations are taken into account.

-Before starting installation, assemble all tools, hardware, and supplies needed• Some items may need to be purchased locally.

After deciding where to install unit, carefully examine Iocation_both inside and outside. Note any potential obstacles or problems. Choose a more suitable location, if necessary.

Electrical Requirements

IWARNINGI

Grounding Instructions

For safety, air conditioner must be grounded. All air conditioners have power supply cord with three-prong grounding plug. To minimize possible electrical shock hazard, power cord must only be plugged into matching grounding wall receptacle in accordance with National Electrical Code (and any applicable local codes and ordinances). If appropriate grounding-type wall receptacle is not available, have properly grounded wall receptacle installed by qualified electrician.

If codes permit and separate grounding wire is used, have qualified electrician determine if grounding path is adequate and uninterrupted by plastic, non-metallic gaskets, or other insulating (non-conductive) materials.

Electrical Connection

A separate (dedicated) circuit is required for units labeled "Use on Single Outlet Circuit Only." Devices covered in this manual require a 60Hz supply. Refer to unit nameplate for exact voltage requirements. Voltage requirements can also be determined by type of plug on air conditioner. See Table 1.

Table 1. Air Conditioner Power Requirements

Unit Plug

Receptacle

Circuit

Rating,

Voltage

Type

Required

Breaker,

"rime

Ratlng On

 

 

Delay Fuse

Nameplate

NEMA No. 5-15P

NEMA NO. _15R

125V-t5AMP

115V

©

To avoid dsk of personal injury or death due to electrical shock:

DO NOT remove warning tag from power cord•

Electrical grounding is required on all air

 

conditioners.

 

Check with a qualified electrician if you are not

 

sure intended electrical outlet is properly

 

grounded.

 

DO NOT ground

to gas line.

DO NOT ground

to cold water pipe if pipe is

 

interrupted by plastic, non-metallic gaskets, or

 

other insulating (non-conducting) materials.

NEMA No. 6-15PNEMANo.@I5R 250V-15AMp

NEMA No. _20P NEMA No. _20R 250V-20AMP

©

NEMA NO. 6_0P NEMANo. _R

25OV-30AMP

23ei208V rated at t2 amperesor Is_s

23G/208Vrated

o_rl2amper_, b_notmo_than

16amperes

208V rated over

16 amperes, but not mot8 _an

24 amperes

• DO NOT modify plug on power cord. If plug does

not fit electrical outlet, have a matching outlet

installed by a qualified electrician.

• DO NOT have a fuse in the neutral or ground

circuit. A fuse in the neutral or ground circuit

could result in an electrical shock.

• DO NOT use an extension cord with this device.

• DO NOT use an adapter plug with this device.

• Observe all local codes and ordinances.

Do not use an extension cord. If air conditioner power supply cord does not reach intended wall receptacle, have qualified electrician install or move appropriate receptacle closer to unit.

Do not use an adapter plug. If intended wall receptacle does not match plug on air conditioner, have qualified electrician replace receptacle with correct type.

Image 6
Contents OwnersManual Model Numbers 78079, 70089, 70129Contents WarrantySafety. Instructions IdangeriParts and Feature Identification Model IdentificationShown removed for easier component identification Sizing Instructions Voltage InstallationInstalling Room Air Conditioners Check with a qualified electrician if you are notInstallation Window Installation Kit PartsInstallation Support Bracket Assembly Icautioni Installing Seal Strip Window seal strip Outdoor sash Window Installation--12000, and 18000 Btu Units Models 70129 Typical Double-Hung Window Window sill Applying Window Sill GasketAttaching Adjusting Foot to Outside Support Attaching Outside Supports to Outer Case Outer caseAdjusting Outer Case Slope Level Typical Cabinet Dimensions Slide-Out Chassis Outer Case DimensionsGeneral Instructions 241/4inches12000 Btu 18000 Btu 163,4inches 193Ainches 24¼ Inches Chamfering Walls That Exceed Outer Case Dimensions Side View Side louversControls Touch Control PanelOperating Instructions Before Turning Air Conditioner OnDelay Start Operation Operating InstructionsFrequency Care and MaintenanceNormal Operating Sounds WeeklyRemoving Air Filter, Method One Air filterBase Pan Maintenance Evaporator Coil, Condenser Coil,Troubleshooting Assistance and Service ServiceAccessories HomeCentrar

78079, 70089, 78189, 70129 specifications

The Kenmore brand has established itself as a trusted name in the appliance industry, and its line of vacuums, including the Kenmore 78189, 78079, 70129, and 70089, showcases the company's commitment to quality, performance, and innovative technology.

The Kenmore 78189 is renowned for its powerful suction and versatility. Equipped with a 2-motor system, it delivers exceptional cleaning performance on both carpets and hard floors. This model features an adjustable height setting, allowing it to accommodate various carpet types while effectively loosening dirt and debris. The sealed HEPA filtration system captures allergens, making it an excellent choice for households with allergy sufferers.

Similarly, the Kenmore 78079 model stands out due to its lightweight design and maneuverability. Despite its compact size, it boasts powerful suction capabilities. This model comes with a range of specialized tools, such as a pet hair attachment and a crevice tool, making it an ideal choice for pet owners. The efficient cyclone technology enhances airflow, preventing clogs and maintaining optimal performance.

The Kenmore 70129 model offers a blend of performance and ease of use. It is equipped with an advanced multi-cyclonic system that ensures consistent suction strength, while the dirt sensor technology alerts users when dirt remains to be picked up. This model also features an easy-to-empty dustbin, which simplifies maintenance.

Lastly, the Kenmore 70089 model is designed with convenience in mind. It features a retractable cord, making storage hassle-free. The model includes an array of onboard tools and a telescoping wand, enhancing its versatility for cleaning above-floor surfaces. Its lightweight design and ergonomic handle ensure a comfortable cleaning experience, reducing strain during extended use.

Overall, the Kenmore 78189, 78079, 70129, and 70089 models exemplify the brand's dedication to developing vacuums that combine powerful cleaning performance with user-friendly features. With advanced technologies like HEPA filtration, multi-cyclonic suction, and specialized attachments, these vacuum cleaners are designed to meet diverse cleaning needs, providing customers with reliable solutions for maintaining a spotless home. Whether tackling pet hair or household dust, these Kenmore models stand out in the competitive appliance market.