FEATURES

 

 

 

 

 

USING

THE AIR CONDITIONER

 

 

 

 

 

 

 

_]_]_

 

To reduce the risk of fire, electric

 

 

 

 

 

 

 

shock, or injury to persons, read the important

 

 

 

 

 

 

 

SAFETY instructions section before operating this

 

 

 

 

 

 

 

appliance

 

 

 

 

 

 

 

 

 

To begin operating the air conditioner after

 

 

 

 

 

 

 

installation,

follow these steps:

 

 

 

 

 

 

 

1. Plug in the air conditioner.(To prevent electrical

 

 

 

 

 

 

 

hazards, do not use an extension cord or an

 

 

 

 

 

 

 

adapter plug.)

 

 

 

 

 

 

 

 

2, Set the exhaust vent to the CLOSE position.

 

 

 

 

 

 

 

3, Set the TEMP Control to the coolest setting,

 

 

 

 

 

 

 

4. Set the MODE Control at the highest COOL level.

1

14

5

 

4

63

213

5. Adjust the louver for comfortable air flow.

 

6, Once the room has cooled, adjust the TEMP and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODE control to the setting you find most

 

 

 

 

 

 

 

comfortable.

 

 

 

 

 

 

 

 

NOTE : I1=the air conditioner is turned off, wait 3

 

 

 

 

 

 

 

minutes before restarting. This allows pressure

 

 

 

 

 

 

 

inside the compressor to equalize. Failure to wait 3

 

 

 

 

 

 

 

minutes before restarting may cause inefficient

 

 

 

 

 

 

 

operation.

 

 

 

 

 

 

 

 

 

If you move the TEMP Control to a warmer, then

 

 

 

 

 

 

 

immediately back to a cooler setting, the unit will

 

 

 

 

 

 

 

shut off. Wait 3 minutes before restarting,

 

 

 

10 11

9

12

 

VENT

CONTROL

 

 

 

 

 

The Vent Control allows the air conditioner to either

 

 

 

 

 

FIG. 22

 

 

 

 

 

recirculate inside air (CLOSE) or exhaust air to the

 

 

 

 

 

 

 

1. Cabinet

 

 

 

 

 

 

outside (OPEN). (FIG. 23)

 

 

 

 

 

 

o The CLOSE position is used when maximum

 

 

 

 

 

 

 

2. Vertical

Air

Direction

Louvers

 

 

 

cooling is desired.

It may also be used for air

3. Cool Air Discharge

 

 

 

 

recirculation without cooling when the air

 

 

 

 

conditioner is set in the FAN position,

4. Inlet Grille

 

 

 

 

 

 

 

 

 

 

The OPEN position

removes stale air from the

 

 

 

 

 

 

 

5. Air Filter

 

 

 

 

 

room

and exhausts

it to the outside. Fresh air is

6. Control

Board

 

 

 

 

drawn into the room through your home's normal

 

 

 

 

air passages.

 

7. Power

Cord

 

 

 

 

 

 

 

 

 

 

 

The OPEN

or CLOSE position can be used with

8. Evaporator

 

 

 

 

 

any fan selection.

 

 

 

 

 

 

 

 

 

 

9.Condenser

10.Compressor

11.Base pan

12.Brace

13.

Upper Guide

PULL

 

14.

Curtain

 

FIG. 23

-10-

Image 10
Contents Acondicionador DE Aire DE Ventana Safety Prevent Accidents Important Safety InstructionsSafety Electrical InformationRecommended Grounding Method National Electrical Code ANSI/NFPAElectrical Service Installation Requirements Installation HardwareInterior wall Track hole InstallationHOW to Install ScrewScrew FIG Am Drainage Drain holeis providedat the rear of theairPart IlF AIR Conditioner is Blocked by Front InstallationRemoval from Window Storm Window FrameCompressor HOW and WHYCapacity and Running Time CondenserVent Control Features UsingLouvers PullAuto Swing AIR Conditioner FeaturesTemp Vertical AIR Direction ControlHOW to Remove Front Grille AIR Filter CleaningHOW to Replace the Front Grille Before Calling for Service Cabinet & Front Grille Assy POS. no Description # = Functional Parts580.72184200 Control BOX Assy C17-C AIR Handling & Cycle Parts Compressor Parts POS. no 11/01Installation KIT Assy Installation KIT Assy

580.72184 specifications

The Kenmore 580.72184 is a powerful air purifier that is designed to create a cleaner and healthier indoor environment. This unit is equipped with advanced features and technologies that effectively eliminate airborne pollutants, making it an excellent choice for allergy sufferers and anyone looking to improve their indoor air quality.

One of the standout features of the Kenmore 580.72184 is its multi-stage filtration system. This includes a HEPA filter capable of capturing 99.97% of particles as small as 0.3 microns, such as dust, pollen, pet dander, and smoke. The pre-filter helps to prolong the life of the HEPA filter by capturing larger particles, while the activated carbon filter is designed to absorb odors and volatile organic compounds (VOCs) from the air. This combination of filtration technologies ensures that the air you breathe is as clean as possible.

In addition to its impressive filtration system, the Kenmore 580.72184 features a smart sensor that automatically adjusts the fan speed based on the air quality in the room. This means that when the air quality is poor, the purifier will work harder to clean the air, and when the air quality improves, the unit will reduce its speed to conserve energy. This feature not only adds convenience but also enhances the energy efficiency of the device.

The air purifier operates quietly, making it suitable for use in bedrooms and other quiet spaces. Its compact design allows it to fit seamlessly into various room sizes, and with its sleek appearance, it can complement any home decor. Furthermore, the Kenmore 580.72184 has a filter replacement indicator, ensuring that users are always aware when it's time to change the filters for optimal performance.

The unit also includes a timer function, allowing users to set it to run for specific periods throughout the day. This flexibility makes it easier to incorporate air purification into your daily routine.

Overall, the Kenmore 580.72184 is a feature-rich air purifier that combines efficiency with user-friendly design. With its powerful filtration system, smart technology, and quiet operation, it stands out as a reliable option for anyone looking to enhance their indoor air quality and promote a healthier living space.