HOW AND WHY

Your room air conditioner provides the following

functions to make hot weather living more comfortable:

Cools and circulates room air.

Lowers humidity by removing excess moisture.

Filters out summertime dust, dirt, and some airborne impurities.

The air conditioner performs these functions by drawing room air through a filter which traps dust and dirt particles. The air then passes over a cooling coil which refrigerates the air and removes excess moisture. The same air is then returned to

the room- cooler, drier, and cleaner. Moisture removed from the room air is carried to the outside

and evaporated.

Your air conditioner is designed to be easy to operate and to provide plenty of cooling power.

Compressor

The modern high efficiency compressor may have a high pitched hum or pulsating noise that cycles on and off.

Fan

 

Unit

Vibration

You may

hear air

The

unit

may vibrate

movement

from the

and

make

noise

fan.

 

because

of poor wall

 

 

or window

 

 

 

construction.

NORMAL SOUNDS FIG.11

Aside from the regular fan motor and compressor sounds coming from your air conditioner, you will once in a while hear a pinging sound. This is the result of moisture being picked up from the air in the room and thrown against the air conditioner's fan. This is normal and should not be cause for concern. Also, do not be alarmed if you hear a slight hissing or

gurgling sound coming from your air conditioner after it is off. These are normal coolant noises.

CAPACITY AND RUNNING TIME

Proper unit size is important in deciding the desired comfort for the area you want to cool. The proper size is determined by the number of square feet in the area to be cooled.

Whenever the heat or humidity load is above normal the air conditioner must run longer and more often

to keep the desired temperature you have selected, Under heavy heat load conditions the air conditioner may need to run constantly to keep the temperature you want.

At times using the HIGH FAN setting to circulate the

room air may make it comfortable even though you do not have the air conditioner set to cool the air.

This will decrease your cost of use.

Condenser

You may hear droplets of water hitting the condenser, causing a pinging or clicking sound.

FIG. 11

-8-

Image 8
Contents Room AIR Conditioner Acondicionador DE Aire DE Ventana Maintenance NumbersImportant Safety Instructions For Your SafetyDo not USE AN Extension Cord Recommended Grounding Method Installation Requirements Installation Hardware Name of Parts QTYInstallation Inner Sill Outer Sill Item a InsideOutside Bracket DrainageWindow Frame Removal from WindowSecure the Guide Panels Capacity and Running Time HOW and WHYNormal Sounds Features Using the AIR ConditionerAIR Conditioner Features AIR Direction AdjustmentAIR Filter Cleaning HOW to Remove the Front GrilleAIR Conditioner Cleaning HOW to Replace the Front GrilleBefore Calling for Service AIR Conditioner will not OperatePage Contacto CON EL Centro DE Servicio Importantes Instrucciones DE Seguridad PORSU Seguridad ARA Prevenir AccidentesMitodo Recomendado DE Conexion a Tierra Respete Todos LOS Codigos Y ReglamentosNo USE Cable Electrico DE Extension Instalacion Piezas DE Montaje 8ERVICIOELECTRICOInstalacion Colocar LA Unidad EN LA VentanaDrenaje Cortinas LateralesFije LOS Paneles Corredizos LA Eliminacion DE LA VentanaInstale EL Acondicionador DE Aire EN LA Ventana Como Y POR QUI Sonidos Normales FiguraUSO DEL Equipo DE Aire Acondicionado 117DE Aire Acondicionado Ajuste Para LA DIRECClON DEL AireLimpieza DEL Filtro DEL Aire Limpieza DEL Equipo DE Aire AcondicionadoFrontal Como Reinstalar LA Parrilla FrontalAntes DE Llamar Para Servicio DETRA8DELPANELDECORATIV0FRONTALHabitacion 8E 81ENTE Demasiado Calida 8E Escuchan RUIDO8 Cuando LA Unidad EST,&,ENFRIANDOPage Page Master Protection Agreements Our Home