Omega WMS-T-AL Units of Measure, Temperature Sensor Placement, Temperature Inputs, Power Supply

Page 5

When audible, Alarm 1 will produce a beep at 400 ms intervals while Alarm 2 will beep at 200 ms intervals.

When the alarms are in the audible mode and both alarms are active, Alarm 2 will have precedence.

The alarm can be put into the silent mode by moving Switch 4 to the off position on the switch block at the bottom of the circuit board. It is necessary to re-boot the WMS-T-AL after moving the switch in order to in able the change.

Units of Measure

It is possible to display temperature values in either °F or °C units. Selection of the unit system to be used is done with Switch 3 on the switch block at the bottom of the circuit board. The Off position is for °F and the On position is for °C. It is necessary to re-boot the WMS-T-AL after moving the switch in order to in able the change.

Temperature Sensor Placement

The validity of temperature signals can be compromised by the choice of the location of the anemometer with respect to the surrounding terrain. Placement of the temperature sensor should follow standards established by agencies such as the World Meteorological Organization (WMO) and the National Oceanic and Atmospheric Administration’s (NOAA) National Weather Service (NWS).

Temperature Inputs

The temperature inputs are P17, TMP1 and P18, TMP2.

Power Supply

Use a 12V AC or DC power supply on the ACin/DCin and ACin/DCgnd terminals.

Earth Ground

Attach a wire of at least 18 AWG or larger to the EARTH terminal. The other end of this wire must be attached to a metal water pipe or a copper-ground-rod. This is the ground path for all of the lightning and electrostatic protection devices incorporated on the WMS-T-AL circuit board. It is very important that this earth ground connection is made! Your WARRANTY may be voided if the earth ground connection is not made.

3

Image 5
Contents User’s Guide Servicing North America Temperature Sensor WMS-T-AL Dual Set Point Temperature Alarm IntroductionGeneral Description Control ModuleMenu Structure Temperature Inputs Temperature Sensor PlacementPower Supply Units of MeasureQuick Start Specifications Page WARRANTY/DISCLAIMER Shop online at omega.com