Dixi XWA11V manual Technical Data, Connections

Page 6

dIXEL

Operating Instructions XWA11V

1598003200

 

 

 

11. TECHNICAL DATA

Housing: self extinguishing ABS

Case: face 100x64 mm; depth 45.5mm

Mounting: J-box or wall-mount option

Frontal protection: IP65

Connections: ¼” fast-on for power, 1/8” fast-on for probes and Digital Inputs

Power supply: 120Vac ± 10%, optional 230Vac ± 10%

Power absorption: 4VA max.

Display: 3 digits, red LED, 14,2 mm high.

Inputs: 1 NTC probe

Digital inputs: 2 free voltages

Relay outputs: Dry Contacts

Light: relay SPST 16A, 120Vac;

Alarm: relay SPST 8A, 120Vac

Other output: alarm buzzer

Data storing: on the non-volatile memory (EEPROM).

Measuring and regulation range:

NTC probe: -40÷110°C (-58÷230°F)

Resolution: 1 °F

Accuracy : ±1 °F

12. CONNECTIONS

Power supply: 120Vac +/- 10% 15A MAX current

Full P/N Ambient Temp / %RH

Date Code

Weiss Instruments, Inc. 905 Waverly Ave. Holtsville, NY 11742 631-207-1200 www.weissinstruments.com

6

Image 6
Contents Please Read Before Using this Manual General DescriptionGeneral Warnings Safety Precautions InterfaceKEY Combinations Press Simultaneously Temp Alarms Setting ProgrammingInstallation and Mounting Light ManagementElectrical Connections Alarm Signals USE of the Programming HOT KEYTechnical Data ConnectionsParameter MAP RangeParameter List EAL