dIXEL | Operating Instructions XWA11V | 1598003200 |
|
|
|
13. PARAMETER MAP
|
| COOLER |
| ** |
|
|
|
|
|
| VALUES |
| FREEZER |
|
| RANGE |
|
LABEL | DESCRIPTION | DEFAULT |
| VALUES | LEVEL |
|
| |
|
|
|
|
|
|
|
| |
ot | Thermostat probe calibration | 0 | 0 | Pr2 |
| 21°F <> 21°F] | ||
CF | Temp measurement unit | F |
| F | Pr2 |
| °C - °F | |
rES | Resolution (only °C) | in |
| in | Pr2 |
| dE - in | |
UT | Display update | 60 | 60 | Pr2 |
| 0 <> 255 (sec) | ||
OnF | Off function enabling | Y |
| Y | Pr2 |
| N - Y | |
|
|
|
|
|
|
| °C[ ALL <> 150,0°] | |
ALU | High Temp alarm setting ** | 50 | 30 | Pr1 |
| °F[ ALL <> 302°] | ||
|
|
|
|
|
|
| °C[ | |
ALL | Low Temp alarm setting ** | 25 | Pr1 |
| ||||
|
|
|
|
|
|
| [0,1°C <>25,5°C] | |
AFH | Temp alarm differential | 2 | 2 | Pr2 |
| [1°F <> 45°F] | ||
ALd | Temp alarm delay | 30 | 30 | Pr1 |
| 0 <> 255 (min.) | ||
dAo | Delay of Temp alarm at | 1.5 | 1.5 | Pr2 |
| 0 <> 24.0 (Hrs / 10 min.) | ||
EdA | Alarm delay at the end of defrost | 30 | 30 | Pr2 |
| 0 <> 255 (min.) | ||
| Delay of Temp alarm after closing |
|
|
|
|
|
|
|
dot | the door | 15 | 15 | Pr2 |
| 0 <> 255 (min.) | ||
LHt | Light timer | 15 | 15 | Pr1 |
| 0 <> 255 (min.) | ||
doA | Open door alarm delay | 15 | 15 | Pr1 |
| 0 <> 255 (min.) | ||
OA1 | First relay configuration | Alr |
| ALr | Pr2 |
| ALr - LHt - OnF | |
oA2 | Second relay configuration | LHt |
| LHt | Pr2 |
| ALr - LHt - OnF | |
AOP | Alarm relay polarity | CL |
| CL | Pr2 |
| OP - CL | |
i1P | Digital input 1 polarity | op |
| oP | Pr2 |
| OP - CL | |
i1L | Door switch to turn light ON | y |
| y | Pr2 |
| n - Y | |
i1F | Digital input 1 operating mode | dor |
| dor | Pr2 |
| EAL - dor- dFr - LHt | |
i2P | Digital input 2 polarity | CL |
| cL | Pr2 |
| OP - CL | |
i2F | Digital input 2 operating mode | Pan |
| PAn | Pr2 |
| EAL - Pan - dFr - LHt | |
| Time interval/delay for digital |
|
|
|
|
|
|
|
did | input alarm | 0 | 0 | Pr2 |
| 0 <> 255 (min.) | ||
tbA | Alarm relay disabling | n |
| n | Pr2 |
| n - Y | |
PbC | Kind of probe | ntc |
| ntc | Pr2 |
| PtC - ntC | |
dP1 | Real T° Probe 1 |
|
|
| Pr2 |
| (probe value) | |
rEL | FW release |
|
|
| Pr2 |
| read only | |
Ptb | Parameter map |
|
|
| Pr2 |
| read only |
Weiss Instruments, Inc. 905 Waverly Ave. Holtsville, NY 11742 | 7 |