Rainbow Technologies RAINBOWE2 manual Troubleshooting guide, Possible Cause

Page 21

troubleshooting guide

This Rainbow appliance has been thoroughly tested and inspected. If a minor issue develops, the following troubleshooting procedures may help identify and correct the issue. If you are unable to resolve the issue, contact an Authorized Rainbow Distributor for service. Any service procedure not listed below should be performed by an Authorized Rainbow Distributor or Service Center.

!WARNING: Disconnect electrical supply before performing maintenance to the unit. Failure to do so could result in electrical shock or personal injury.

ISSUE

The Rainbow motor is not running.

Noticeably reduced airflow.

Unit discharges dust.

Heavy foaming in water basin.

POSSIBLE CAUSE

Rainbow not properly latched to water basin. Air inlet screen is plugged with debris.

Not firmly plugged in.

Air inlet screen is plugged with debris.

Automatic resetting motor protector has tripped.

Defective cord, switch or Rainbow.

Rainbow not correctly positioned on water basin.

Plugged hose, wand, attachment or Power Nozzle.

HEPA Neutralizer needs servicing or replacement.

Rainbow is running on low speed.

Separator is clogged or dirty.

Low level of water in basin.

Excessively dirty water in basin.

Hole in HEPA Neutralizer.

Soapy contaminant in water basin.

High level of water in basin.

POSSIBLE SOLUTION

Ensure side latches of water basin are locked.

Plug unit in firmly or try another outlet.

Clean off debris thoroughly.

Turn Rainbow off. Leave off for 30 seconds. Turn Rainbow back on.

Contact an Authorized Rainbow Distributor or Service Center.

Ensure Rainbow is properly seated and latched onto water basin.

Remove obstruction from clogged area.

Remove HEPA Neutralizer and clean or replace. (See page 19)

Turn power switch to high speed.

Remove separator and clean. (See page 10)

Fill water basin to correct level.

Replace with clean water.

Contact an Authorized Rainbow Distributor or Service Center.

Replace with clean water.

Empty water basin and refill to correct level.

20

Image 21
Contents Rainbowsystem.com Page Ownership identification for you Customer care numberMessage from Rexair Rainbow is certifiedImportant safety instructions Save These Get acquainted with your rainbow Trigger Lock Switch Power Selector SwitchAirflow Control Vent Attachment CaddyQuick-start guide Page Always empty and clean the water basin… Change the water when dirty…Clean the separator… Proper use & careComplete home cleaning solution Cleaning the attachments…Using the Airflow Adapter… To clean carpeted floors… To clean bare floors…To clean walls… To clean narrow spaces…To clean vents… To clean furniture fabric…For fresh, water-washed air… To deodorize…To clean under refrigerators… To clean tight areas…To freshen bedding… To inflate or blow air…Enhance your rainbow with accessories Active Edge Cleaning… Rainbow power nozzlePower nozzle assembly & operation AssemblyOperation Replacing the power nozzle belt Remove the Hepa Neutralizer Hepa neutralizer maintenanceRinse the Hepa Neutralizer Dry the Hepa NeutralizerPossible Cause Troubleshooting guideWands not connected Wand connections not made Rainbow fragrances & cleaning solutions Limited warranty Clean Air Delivery Rate