Therma-Stor Products Group Rx Free-Standing Dehumidification Safety Precautions, Operation

Page 3

SAFETY PRECAUTIONS

The water is discharged through a 20’ long white hose coming from the unit bottom. The hose is about the diameter of a TV coaxial cable and can be routed in much the same way. If a drain is not convenient, a small hole can be drilled through the floor or wall to access a drain or outside. The hose can be extended if needed; it should, however, be extended with a hose of larger inner diameter (1/4” I.D. or greater) to avoid overloading the pump. Larger diameter hose is available from the factory or may be purchased from many hardware stores. If the hose can not be routed to a drain or outside, a reservoir container with an overflow switch can be used.

If the hose is routed outside, it must exit the building with a downward slant. This will allow the water in the hose to drain from it when the pump shuts off, preventing it from freezing.

Pump failure will cause the unit to stop dehumidifying via a safety switch.

2.4 Optional Reservoir Container

If the condensate discharge hose cannot be routed to a drain or outside, it can empty into a conveniently located container. This container (supplied by the customer) can be any size greater than 1/2 gallon. It can be emptied manually or by a pump (supplied by the customer).

CAUTION: It is strongly recommended that a safety overflow switch be used to prevent the container from overflowing and causing potentially costly water damage.

2.5 Safety Overflow Switch

A Safety Overflow Switch is available from the factory (see parts list). It consists of a float switch on a weighted cord with a male- female piggyback plug. The cord is secured to the container with the float and weight inside; the weight is separated from the float and container wall.

3 Operation

3.1 Top Removal

The top of the unit must be removed to access the humidity control knob, blower switch, and standard air filter. The standard metal top is removed by pulling it horizontally toward the front about 3/4”, then lifting it upward (the unit front is opposite from the side that the air comes out).

3.2 Humidity Control Adjustment

The humidity control knob is located under the removable top (top must be lifted off to access). Turning the knob clockwise lowers humidity. Turning it counter clockwise to the stop shuts it off.

The dehumidifier will run continuously until the relative humidity (RH) is reduced to the humidity control setting. Setting the humidity control to lower RH levels will NOT increase the unit’s dehumidification rate, it will simply run longer to reduce the area’s RH to the setting.

The Santa Fe Rx unit (and refrigerant based dehumidifiers in general) will reduce a warm space’s RH to a lower level than that of a cool space. For example, the Santa Fe Rx may reduce an 80°F space to 30% RH. However, if the same space is 65°F, it may only reduce to a 40% RH. It is therefore pointless to set the humidity control to excessively low levels in cool rooms. Doing so will result in long periods of ineffective dehumidifier run time and will consume electricity needlessly.

A quality humidity meter is supplied upon return of the warranty registration card; it is recommended to accurately monitor humidity levels. Additional meters are available for purchase from the factory.

3.3 Blower Switch

Lifting off the top accesses the blower switch. It is located near the humidity control dial.

Turning the blower switch to FAN ON will cause the blower to run continuously, whether the unit is dehumidifying or not. This function is desirable if the unit is used for air filtering.

4. Maintenance

4.1 Air Filter

The Santa Fe Rx is equipped with a standard MERV 11 65% Efficient disposable pleated fabric air filter. Optional 95% efficiency, 99.97% efficiency HEPA grade and activated carbon filters are available (see Section 4.1A).

The standard filter is located beneath the removable top. The filter is removed by lifting the front edge up first, then the back. It should be checked every 6 months. Operating the unit with a dirty filter will reduce dehumidifier capacity and efficiency.If dirty, the pleated fabric filter can generally be vacuumed cleaned several times before needing replacement. Replacement filters can be ordered from the factory or purchased locally if available. Its nominal size is 16” x 20” x 2” thick. Its efficiency is 65% per ASHRAE std. 52.1-1992.

DO NOT operate the unit without the filters or with a less effective filter. The heat exchange coils inside the unit could become clogged which would reduce performance and require disassembly to clean.

3

Santa Fe Rx Installer’s & Owner’s Manual

Image 3
Contents Hvac Installer Please Leave Manual for Homeowner Table of Contents Safety Precautions MaintenanceOperation Service For Hvac Installer onlyBlower Replacement Compressor/Capacitor ReplacementRefrigerant Charging Defrost Thermostat 6A Replacing a Burned out Compressor6B Replacing a Compressor-Nonburn Out Humidity ControlSanta FE Rx Wiring Diagram QTY Description Santa FE Rx Filter Frame Assembly How to prepare the Santa Fe Rx for operation Santa FE Rx SET UP InstructionsSanta FE Rx Laminate TOP KIT Santa Fe Rx Dehumidifier Limited Warranty PO Box 8680 Madison, WI Phone 608-222-5301 Fax

Rx Free-Standing Dehumidification specifications

Therma-Stor Products Group has emerged as a leader in providing innovative solutions for moisture control, and one of their standout offerings is the Rx Free-Standing Dehumidification unit. This product is engineered to meet the needs of various environments, including residential and commercial spaces that require efficient humidity management.

A primary feature of the Rx Free-Standing Dehumidifier is its impressive moisture removal capacity. With an ability to extract up to 70 pints of moisture per day, it is well-suited for areas prone to high humidity levels, such as basements, laundry rooms, and bathrooms. This high capacity ensures that spaces remain dry, preventing the growth of mold and mildew, which can cause health issues and property damage.

Incorporating advanced technologies, the Rx model is equipped with a state-of-the-art digital humidistat. This feature allows users to set their desired humidity levels, ensuring the unit operates only when necessary. The digital display offers real-time humidity readings, making it easy to monitor environmental conditions and adjust settings accordingly. Additionally, the automatic restart function is a valuable benefit during power interruptions. The unit can resume operation under the previous settings, protecting your space from potential moisture buildup after outages.

The Rx Free-Standing Dehumidifier also emphasizes user-friendliness. It features a continuous drainage option, which eliminates the need for frequent manual emptying of the water tank. This continuous drainage can be connected to a standard hose, making it ideal for long-term, unattended use. The unit is designed for portability, with robust casters that allow for easy movement between rooms, accommodating the dynamic needs of homeowners and businesses alike.

Furthermore, the quiet operation of the Rx model ensures that it can perform effectively without disrupting daily activities. Its energy-efficient design means lower energy costs while still delivering optimal performance. The unit is also built with durable materials that ensure longevity, making it a reliable investment for long-term humidity control.

In summary, Therma-Stor's Rx Free-Standing Dehumidification unit combines high performance with user-friendly features, advanced technology, and energy efficiency. This makes it an excellent choice for anyone seeking to maintain a healthy and comfortable living or working environment.