Optional | Direct Warm & Dry Air | |
Toward Window Glass | ||
Exhaust Ventilator | ||
| ||
Low = 165 CFM |
| |
high = 290 CFM |
| |
| ||
ent |
| |
Vehere Pool & Spa |
| |
Humidity Controller |
| |
Dehumidistats |
| |
for |
| |
remote Vehere |
|
Figure 4: Installation in humid area with ducting.
3.1C In Humid Area, Duct Inlet and/or Outlet
If the pool room is very large or has high ceilings, dehumidification can be improved by adding an inlet and/or outlet duct to circulate and destratify stagnant areas. Add inlet or outlet ducting to create flow across the area’s greatest length. For areas with ceilings higher than 12’, use an inlet duct to draw warm, moist air from near the ceiling. See section 4.5 for attaching duct collars & ducting. (See Fig. 4)
3.1D In Remote Area, Duct Inlet & Outlet
It is often desirable, to install the Vehere in an adjacent equipment room or unfinished area. Air is then transferred between the humid room and the unit via ducting. Remotely mount the Vehere humidity control in the humid room and wire to the Vehere. Local electrical codes must be followed when wiring the control. Refer to the “Mounting the Humidity Sensor/Controller” section which follows. (See Fig. 5)
Optional
ent |
Vehere Pool & Spa
Humidity Controller
Direct Warm & Dry Air
Toward Window Glass
Dehumidistats
for
remote Vehere
Figure 5: Installation in remote area with ducting.
| www.thermastor.com • sales@thermastor.com |