Bryant 582A manual Application Data

Page 17

APPLICATION DATA

1.CONDENSATE TRAP—A 2-in. condensate trap must be field supplied.

2.DUCTWORK—Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges.

3.TO CONVERT A UNIT TO DOWNFLOW DISCHARGE— Units are equipped with factory-installed inserts in the down-flow openings. Remove the inserts similar to remov- ing an electrical knock-out. Use an accessory duct cover to seal the horizontal discharge openings in the unit. Units installed in horizontal discharge orientation do not require duct covers.

4.AIRFLOW—Units are draw-thru in the Cooling mode and blow-thru in the Heating mode.

5.MAXIMUM COOLING AIRFLOW—To minimize the possibility of condensate blow-off from the evaporator, airflow through the units should not exceed 450 cfm per ton.

6.MINIMUM COOLING AIRFLOW—The minimum cooling airflow is 350 cfm per ton.

7.MINIMUM AMBIENT COOLING OPERATION TEMPERATURE—For all standard units the minimum ambient operating temperature is 55°F. With accessory low ambient temperature kit, units can operate at temperatures down to 0°F.

8.MINIMUM TEMPERATURE—Air entering the heat exchanger in heating mode must be a minimum of 50°F continuous and/or 45°F intermittent.

17

Image 17
Contents DURABLE, Dependable Components Available OptionsEfficient Operation 582A N 024 040 a a a D Model Number NomenclatureARI* Capacities Cooling Capacities and Efficiencies Unit 582A Heating Input Output Capacity TemperatureHeating Capacities and Efficiencies SeerUnit Size 582A Physical DataFIELD-INSTALLED Accessories Options and AccessoriesFACTORY-INSTALLED Options Filter Rack Manual Outdoor Air Damper Options and Accessories EconomizerCharacteristics Base Unit Dimensions 582A018-042Unit Electrical Unit Weight Center of Gravity Characteristics Base Unit Dimensions 582A048-060Full Perimeter Curb Accessory DimensionsUnit Size ODS Order Number 582A In. mmII Select Unit Based on Required Cooling Capacity Selection Procedure with exampleSelect Unit That Corresponds to Power Source Available Performance Data NET Cooling Capacities Performance Data NET Cooling Capacities Temp F Evaporator AIR CFM/BF OUTDOOR-AIR 582A0601750/0.039 2000/0.053 2250/0.079 Evaporator Air Ewb FCFM ECONOMIZER/1-IN. Filter Pressure Drop Performance DataWET Coil Pressure Drop Outdoor Sound Octave Band Data DecibelsVertical Discharge Typical Piping and WiringHorizontal Discharge NECApplication Data 582A018-060 208/230-1 Typical Wiring SchematicIGC Typical Wiring SCHEMATIC, 582A030-060 208/230-3-60Typical Wiring SCHEMATIC, 582A036-060 Range Electrical Data582A Min RLA LRA FLA MCAOperating Sequence ControlsPackaged HEATING/COOLING Units Constant Volume Application Guide SpecificationsPart 1 General Part 2 ProductsHeating & Cooling Systems Guide Specifications

582A specifications

The Bryant 582A is a notable model in the realm of air conditioning and heating systems, designed to offer enhanced comfort, energy efficiency, and reliability. As a part of Bryant's extensive line of HVAC solutions, the 582A embodies cutting-edge technology and engineering designed to meet the needs of modern homeowners.

One of the prominent features of the Bryant 582A is its high efficiency. With SEER ratings that can reach up to 16, this model ensures that homeowners experience lower energy bills while enjoying consistent temperature control. The system is designed to operate efficiently even in extreme weather conditions, highlighting its versatility for various climates.

At the core of the Bryant 582A is its advanced two-stage compressor technology. This feature enables the unit to run at lower capacities during mild weather, thereby conserving energy while still providing the necessary cool air. During hotter days, the system automatically ramps up to its full capacity, ensuring that it can effectively manage the heat. This two-stage operation also contributes to quieter performance and improved humidity control, making the indoor environment more comfortable.

The Bryant 582A boasts a durable construction, featuring a galvanized steel cabinet that is designed to withstand the elements. The unit is coated with a weather-resistant finish, which is essential for maintaining its integrity and appearance over time. Additionally, the model is designed with maintenance in mind. The easy-access panels allow for simplified service, ensuring that routine maintenance can be performed without hassle.

Technologically, the Bryant 582A includes an integrated smart thermostat option, allowing homeowners to control their HVAC system remotely. This feature not only adds convenience but also enhances energy savings by allowing users to adjust settings based on their schedules. Furthermore, the system is compatible with Bryant's Evolution control system, which provides advanced communication between indoor and outdoor units, optimizing performance.

In terms of indoor air quality, the Bryant 582A can be paired with various air purification options, ensuring that the air circulating throughout the home is clean and free from allergens. This capability makes it a valuable addition for those who prioritize health and well-being in their living environment.

Overall, the Bryant 582A stands out as an efficient, reliable, and technologically advanced HVAC solution. Its combination of energy-saving features, durable construction, and innovative controls positions it as a leading choice for homeowners seeking comfort and efficiency in their heating and cooling systems. Investing in the Bryant 582A means ensuring year-round comfort, cost savings, and enhanced indoor air quality for your home.