Bryant 582A manual Guide Specifications, Heating & Cooling Systems

Page 24

GUIDE SPECIFICATIONS (cont)

K.Electrical Requirements:

All unit power wiring shall enter the unit cabinet at a single location.

L.Motors:

1.Compressor motors shall be of the refrigerant-cooled type with line-break thermal and current overload protection.

2.All fan motors shall have permanently lubricated bear- ings, and inherent, automatic reset, thermal overload protection.

3.Condenser-fan motor shall be totally enclosed. M. Special Features:

1.Louvered Grille:

Wire grille shall be standard on all units. Louvered grille shall be available as a factory-installed option to provide hail guard and vandalism protection.

2.Coil Options:

Shall include factory-installed optional copper/copper and vinyl-coated refrigerant coils.

3.Economizer:

a.Economizer controls capable of providing free cooling using outside air.

b.Equipped with low leakage dampers not to exceed 3% leakage, at 1.0 in. wg pressure differential.

c.Spring return motor shuts off outdoor damper on power failure.

4.Flat Roof Curb:

Curbs shall have seal strip and a wood nailer for flashing and shall be installed per manufacturer’s instructions.

5.Manual Outdoor Air Damper:

Package shall consist of damper, birdscreen, and rainhood which can be preset to admit outdoor air for year-round ventilation.

7.Natural-to-Propane Conversion Kit:

Shall be complete with all required hardware to con- vert to liquid propane (LP) operation at 3.5 in. wg manifold pressure.

8.Low Ambient Package:

Shall consist of a solid-state control and condenser coil temperature sensor for controlling condenser-fan

motor operation, which shall allow unit to operate down to 0° F outdoor ambient temperature.

9.Filter Rack Kit:

Shall provide filter mounting for downflow applications.

10.Controls Upgrade Kit:

Shall provide high and low pressure safety protection.

11.Square-To-Round Duct Transitions:

Shall have the ability to convert the supply and return openings from rectangular to round.

12.Compressor Protection:

Solid-state control shall protect compressor by pre- venting “short cycling.”

13.Duct Conversion Kit:

Shall enable conversion of a factory-supplied side discharge unit to horizontal discharge airflow unit.

14.Crankcase Heater:

Shall provide anti-floodback protection for low-load cooling applications.

15.High-Altitude Kit:

Shall consist of natural gas orifices to compensate for gas heat operation at 2001 to 4500 ft above sea level.

16.Low NOx :

Shall provide NOx reduction to values below 40 nanograms/joule to meet California emission requirements as shipped from the factory.

6. Thermostat:

17. Compressor Hard Start Kit:

 

To provide for one-stage heating and cooling in ad- dition manual or automatic changeover and indoor fan control.

Shall provide additional starting torque for single- phase compressors.

Heating & Cooling Systems

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS

Cancels PDS 582.18.1

© 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231

24

Printed in U.S.A.

3-00

CATALOG NO. 5258-202

Image 24
Contents Available Options Efficient OperationDURABLE, Dependable Components Model Number Nomenclature 582A N 024 040 a a a DUnit 582A Heating Input Output Capacity Temperature ARI* Capacities Cooling Capacities and EfficienciesHeating Capacities and Efficiencies SeerPhysical Data Unit Size 582AOptions and Accessories FACTORY-INSTALLED OptionsFIELD-INSTALLED Accessories Options and Accessories Economizer Filter Rack Manual Outdoor Air DamperBase Unit Dimensions 582A018-042 Unit Electrical Unit Weight Center of GravityCharacteristics Base Unit Dimensions 582A048-060 CharacteristicsAccessory Dimensions Full Perimeter CurbUnit Size ODS Order Number 582A In. mmSelection Procedure with example Select Unit That Corresponds to Power Source AvailableII Select Unit Based on Required Cooling Capacity Performance Data NET Cooling Capacities Performance Data NET Cooling Capacities 582A060 Temp F Evaporator AIR CFM/BF OUTDOOR-AIR1750/0.039 2000/0.053 2250/0.079 Evaporator Air Ewb FCFM Performance Data ECONOMIZER/1-IN. Filter Pressure DropWET Coil Pressure Drop Outdoor Sound Octave Band Data DecibelsTypical Piping and Wiring Vertical DischargeHorizontal Discharge NECApplication Data Typical Wiring Schematic 582A018-060 208/230-1Typical Wiring SCHEMATIC, 582A030-060 208/230-3-60 IGCTypical Wiring SCHEMATIC, 582A036-060 Electrical Data Range582A Min RLA LRA FLA MCAControls Operating SequenceGuide Specifications Packaged HEATING/COOLING Units Constant Volume ApplicationPart 1 General Part 2 ProductsGuide Specifications Heating & Cooling Systems

582A specifications

The Bryant 582A is a notable model in the realm of air conditioning and heating systems, designed to offer enhanced comfort, energy efficiency, and reliability. As a part of Bryant's extensive line of HVAC solutions, the 582A embodies cutting-edge technology and engineering designed to meet the needs of modern homeowners.

One of the prominent features of the Bryant 582A is its high efficiency. With SEER ratings that can reach up to 16, this model ensures that homeowners experience lower energy bills while enjoying consistent temperature control. The system is designed to operate efficiently even in extreme weather conditions, highlighting its versatility for various climates.

At the core of the Bryant 582A is its advanced two-stage compressor technology. This feature enables the unit to run at lower capacities during mild weather, thereby conserving energy while still providing the necessary cool air. During hotter days, the system automatically ramps up to its full capacity, ensuring that it can effectively manage the heat. This two-stage operation also contributes to quieter performance and improved humidity control, making the indoor environment more comfortable.

The Bryant 582A boasts a durable construction, featuring a galvanized steel cabinet that is designed to withstand the elements. The unit is coated with a weather-resistant finish, which is essential for maintaining its integrity and appearance over time. Additionally, the model is designed with maintenance in mind. The easy-access panels allow for simplified service, ensuring that routine maintenance can be performed without hassle.

Technologically, the Bryant 582A includes an integrated smart thermostat option, allowing homeowners to control their HVAC system remotely. This feature not only adds convenience but also enhances energy savings by allowing users to adjust settings based on their schedules. Furthermore, the system is compatible with Bryant's Evolution control system, which provides advanced communication between indoor and outdoor units, optimizing performance.

In terms of indoor air quality, the Bryant 582A can be paired with various air purification options, ensuring that the air circulating throughout the home is clean and free from allergens. This capability makes it a valuable addition for those who prioritize health and well-being in their living environment.

Overall, the Bryant 582A stands out as an efficient, reliable, and technologically advanced HVAC solution. Its combination of energy-saving features, durable construction, and innovative controls positions it as a leading choice for homeowners seeking comfort and efficiency in their heating and cooling systems. Investing in the Bryant 582A means ensuring year-round comfort, cost savings, and enhanced indoor air quality for your home.