Bryant Complete Wiring Diagram and Parts List for Heating Systems

Page 20

TYPICAL WIRING SCHEMATIC, 582A036-060; 460-3-60

 

 

LEGEND

 

AHA

Adjustable Heat Anticipator

NEC

National Electrical Code

BR

Blower Relay

OFM

Outdoor-Fan Motor

C

Contactor

QT

Quadruple Terminal

CAP

Capacitor

RS

Rollout Switch

COMP

Compressor Motor

SEN

Sensor

CR

Combustion Relay

SW

Switch

CS

Centrifugal Switch

TRAN

Transformer

EQUIP —

Equipment

 

Field Splice

FS

Fusible Link

 

FU

Fuse

 

Terminal (Marked)

GND

Ground

 

GV

Gas Valve

 

Terminal (Unmarked)

GVR

Gas Valve Relay

 

 

 

HS

Hall Effect Sensor

 

Splice

HV

High Voltage

 

Splice (Marked)

I

Ignitor

 

IDM

Induced-Draft Motor

 

Factory Wiring

IFC

Indoor-Fan Contactor

 

 

Field Control Wiring

IFM

Indoor-Fan Motor

 

IGC

Integrated Gas Unit Controller

 

Field Power Wiring

L1

Line

 

Accessory or Optional Wiring

LS

Limit Switch

 

 

To Indicate Common Potential

LS1

Limit Switch

 

MGV

Main Gas Valve

 

Only: Not to Represent Wiring

NOTES:

1.If any of the original wires furnished are replaced, they must be replaced with type 90 de- gree C wire or its equivalent.

2.See price pages for thermostat and subbases.

3.Use 75 degree C copper conductors for field installation.

4.On all units, for GE motors wire as follows: For high speed IFM, disconnect RED wire from IGC:BM and connect BLK wire from IFM. For medium speed, disconnect RED wire from IGC:BM and connect BLU wire from IFM.

20

Image 20
Contents DURABLE, Dependable Components Available OptionsEfficient Operation Model Number Nomenclature 582A N 024 040 a a a DUnit 582A Heating Input Output Capacity Temperature ARI* Capacities Cooling Capacities and EfficienciesHeating Capacities and Efficiencies SeerPhysical Data Unit Size 582AFIELD-INSTALLED Accessories Options and AccessoriesFACTORY-INSTALLED Options Options and Accessories Economizer Filter Rack Manual Outdoor Air DamperCharacteristics Base Unit Dimensions 582A018-042Unit Electrical Unit Weight Center of Gravity Base Unit Dimensions 582A048-060 CharacteristicsAccessory Dimensions Full Perimeter CurbUnit Size ODS Order Number 582A In. mmII Select Unit Based on Required Cooling Capacity Selection Procedure with exampleSelect Unit That Corresponds to Power Source Available Performance Data NET Cooling Capacities Performance Data NET Cooling Capacities 582A060 Temp F Evaporator AIR CFM/BF OUTDOOR-AIR1750/0.039 2000/0.053 2250/0.079 Evaporator Air Ewb FCFM Performance Data ECONOMIZER/1-IN. Filter Pressure DropWET Coil Pressure Drop Outdoor Sound Octave Band Data DecibelsTypical Piping and Wiring Vertical DischargeHorizontal Discharge NECApplication Data Typical Wiring Schematic 582A018-060 208/230-1Typical Wiring SCHEMATIC, 582A030-060 208/230-3-60 IGCTypical Wiring SCHEMATIC, 582A036-060 Electrical Data Range582A Min RLA LRA FLA MCAControls Operating SequenceGuide Specifications Packaged HEATING/COOLING Units Constant Volume ApplicationPart 1 General Part 2 ProductsGuide Specifications Heating & Cooling Systems

582A specifications

The Bryant 582A is a notable model in the realm of air conditioning and heating systems, designed to offer enhanced comfort, energy efficiency, and reliability. As a part of Bryant's extensive line of HVAC solutions, the 582A embodies cutting-edge technology and engineering designed to meet the needs of modern homeowners.

One of the prominent features of the Bryant 582A is its high efficiency. With SEER ratings that can reach up to 16, this model ensures that homeowners experience lower energy bills while enjoying consistent temperature control. The system is designed to operate efficiently even in extreme weather conditions, highlighting its versatility for various climates.

At the core of the Bryant 582A is its advanced two-stage compressor technology. This feature enables the unit to run at lower capacities during mild weather, thereby conserving energy while still providing the necessary cool air. During hotter days, the system automatically ramps up to its full capacity, ensuring that it can effectively manage the heat. This two-stage operation also contributes to quieter performance and improved humidity control, making the indoor environment more comfortable.

The Bryant 582A boasts a durable construction, featuring a galvanized steel cabinet that is designed to withstand the elements. The unit is coated with a weather-resistant finish, which is essential for maintaining its integrity and appearance over time. Additionally, the model is designed with maintenance in mind. The easy-access panels allow for simplified service, ensuring that routine maintenance can be performed without hassle.

Technologically, the Bryant 582A includes an integrated smart thermostat option, allowing homeowners to control their HVAC system remotely. This feature not only adds convenience but also enhances energy savings by allowing users to adjust settings based on their schedules. Furthermore, the system is compatible with Bryant's Evolution control system, which provides advanced communication between indoor and outdoor units, optimizing performance.

In terms of indoor air quality, the Bryant 582A can be paired with various air purification options, ensuring that the air circulating throughout the home is clean and free from allergens. This capability makes it a valuable addition for those who prioritize health and well-being in their living environment.

Overall, the Bryant 582A stands out as an efficient, reliable, and technologically advanced HVAC solution. Its combination of energy-saving features, durable construction, and innovative controls positions it as a leading choice for homeowners seeking comfort and efficiency in their heating and cooling systems. Investing in the Bryant 582A means ensuring year-round comfort, cost savings, and enhanced indoor air quality for your home.