Lennox International Inc 15GCSX, Gas Packaged Units installation instructions Location Selection

Page 4

WARNING

Product contains fiberglass wool.

Disturbing the insulation in this product during installation, maintenance, or repair will expose you to fiberglass wool dust. Breathing this may cause lung cancer. (Fiberglass wool is known to the State of California to cause cancer.)

Fiberglass wool may also cause respiratory, skin, and eye irritation.

To reduce exposure to this substance or for further information, consult material safety data sheets available from address shown below, or contact your supervisor.

Lennox Industries Inc.

P.O. Box 799900

Dallas, TX 75379−9900

These units must be installed in accordance with all applicable national and local safety codes.

These instructions are intended as a general guide and do not supersede local codes in any way. Consult authorities having jurisdiction before installation.

If components are to be added to a unit to meet local codes, they are to be installed at the dealer’s and/or customer’s expense.

These units are design listed by UL in both the United States and Canada as follows:

DFor use as a forced air furnace with cooling.

DFor outdoor installation only.

DFor installation on combustible material.

DFor use with natural gas or L.P./propane gas only. Use of L.P./propane gas requires installation of an L.P. conversion kit, which must be ordered separately.

These units are not suitable for use with conventional venting systems.

The following safety requirements must also be met when the 15GCSX units are installed:

1 − Use only with the type of fuel approved for use with this appliance. Refer to the unit rating plate.

2 − Position, locate and install the 15GCSX unit only as outlined in these instructions.

3 − Provide adequate clearance around the vent hood as specified in these instructions.

4 − Do not use an open flame to check for gas leaks. Use a commercially available soap solution, which has been designed specifically to check for gas leaks. Refer to the Gas Supply and Piping section.

5 − Check the unit operation after start−up to make sure that the 15GCSX is operating within the intended temperature rise range. The duct system must be designed to provide an external static pressure within the allowable range. Refer to the unit rating plate.

Lennox does not recommend the use of 15GCSX units as a construction heater during any phase of construction. Very low return air temperatures, harmful vapors and operation of the unit with clogged or misplaced filters will damage the unit.

15GCSX units may be used for heating of buildings or structures under construction, if the following conditions are met:

DThe vent hood must be installed per these installation instructions.

DA room thermostat must control the furnace. The use of fixed jumpers that will provide continuous heating is not allowed.

DThe return air duct must be provided and sealed to the furnace.

DReturn air temperature range between 60°F (16°C) and 80°F (27°C) must be maintained.

DAir filters must be installed in the system and must be maintained during construction.

DAir filters must be replaced upon construction completion.

DThe input rate and temperature rise must be set per the unit rating plate.

DOne hundred percent (100%) outdoor air must be provided for combustion air requirements during construction. Installation of this unit in its intended outdoor location will accomplish this.

DThe heat exchanger, components, duct system, air filters and evaporator coil must be thoroughly cleaned following final construction clean−up.

DThe unit operating conditions (including ignition, input rate, temperature rise and venting) must be verified according to these installation instructions.

NOTE − The Commonwealth of Massachusetts stipulates these additional requirements:

D Gas furnaces shall be installed by a licensed plumber or gas fitter only.

DThe gas cock must be

DWhen flexible connectors are used, the maximum length shall not exceed 36".

Location Selection

Use the following guidelines to select a suitable location for these units.

1 − Unit is designed for outdoor installation only. Unit must be installed so all electrical components are protected from water.

2 − Condenser coils must have an unlimited supply of air. 3 − For ground level installation, use a level pre−fabricated pad or use a level concrete slab with a minimum thickness of 4 inches. The length and width should be at least 6 inches greater than the unit base. Do not tie

the slab to the building foundation.

4 − Maintain level within a tolerance of 1/4 inch maximum across the entire length or width of the unit.

Page 4

Image 4
Contents Table of Contents Retain These Instructions For Future Reference15GCSX Unit Dimensions − inches mm LbsParts Arrangement Safety Information GeneralShipping & Packing List Location Selection Rigging & Setting Unit Accessory Lift KitService Clearances − Inches Millimeters ClearancesVent Hood Installation Vent Hood InstallationExisting Common Vent Systems Page Filters Condensate DrainTypical Condensate Drain Supply & Return Duct Connections Unit Filter SizeRemoving Supply and Return Air Opening CoversGas Piping and Electrical Conduit Access CompressorsGas Supply and Piping Gas Heat Application DataDrip Leg Installation Pressure Test Gas PipingIsolate Gas Valve To Pressure Test Gas piping recommendations208/230 Line Voltage Wiring Heat Anticipator SettingElectrical Thermostat15GCSX Series Gas Packaged Units Typical Wiring Diagram Blower Control A54 Blower Control A54Cool Cooling Start−Up Normal Operating Pressures Heating Start−UpHoneywell VR8205 Series Gas Valve Checking and Adjusting Gas Input Post Start−up Check List GasHigh Altitude Information Heating Sequence of OperationBlower Delay − Heating Unit ControlsBlower Control A54 Ignition Control A3Pressure Switch Rollout SwitchIgnition Control Ignition Control LED CodesComfort Alert Code Auto−Reset Function Condenser Fan ClearancesSystem Operation Monitor Lsom System Operation Monitor A132System Operation Monitor LED Troubleshooting Codes Maintenance Planned ServiceRepair Parts & Accessories
Related manuals
Manual 4 pages 39.07 Kb

Gas Packaged Units, 15GCSX specifications

Lennox International Inc. is a leading name in the HVAC industry, renowned for its innovative and energy-efficient products. Among its featured offerings are the 15GCSX Gas Packaged Units, specifically designed to provide reliable heating and cooling performance for residential and light commercial applications.

The 15GCSX models stand out with their impressive efficiency ratings, achieving up to 14 SEER (Seasonal Energy Efficiency Ratio) for cooling and 81% AFUE (Annual Fuel Utilization Efficiency) for heating. This ensures that users can enjoy a comfortable indoor environment while also managing energy costs, making them an environmentally friendly choice.

One of the key features of the 15GCSX is its compact design, allowing for easy installation in tight spaces. This is particularly beneficial for urban settings where space can be at a premium. The unit’s all-in-one design integrates both heating and cooling capabilities, eliminating the need for separate systems and simplifying maintenance.

The 15GCSX Gas Packaged Units utilize advanced technologies to optimize performance. Equipped with Lennox’s proprietary iComfort technology, these units can connect to smart thermostats, allowing users to monitor and adjust settings remotely. This innovation enhances energy savings and provides users with full control over their indoor climate, contributing to enhanced comfort levels.

In terms of durability, the 15GCSX models feature a robust construction, complete with weather-resistant cabinet materials designed to withstand the elements. The unit’s stainless steel heat exchanger is built for longevity and efficiency, further enhancing the overall reliability of the system.

Noise reduction is another critical consideration in the design of the 15GCSX units. They come equipped with a specially designed, quiet-running fan and compressor that help to minimize operational sound levels, ensuring a peaceful indoor environment during use.

In conclusion, the Lennox 15GCSX Gas Packaged Units represent a high-quality solution for efficient heating and cooling needs. With their combination of advanced technology, energy efficiency, compact design, and durability, these units are an excellent choice for homeowners and businesses seeking reliable climate control. The integration of smart features and silent operation further solidifies their position as a preferred option in the HVAC market.