Goodman Mfg CPG SERIES installation instructions CPG090 Standard Belt Drive Horizontal

Page 24

APPENDIX A BLOWER PERFORMANCE DATA

BELT DRIVE - STANDARD HORIZONTAL

CPG090 STANDARD BELT DRIVE HORIZONTAL

ESP, In

 

 

 

 

 

 

 

 

TURNS OPEN

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

2

 

 

 

3

 

 

4

 

 

5

 

H2O

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

 

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

3381

703

0.99

3078

659

0.78

0.3

 

 

 

 

 

 

3560

796

1.26

3271

 

747

1.02

2946

703

0.82

2604

659

0.63

0.5

 

 

 

3492

841

1.36

3159

799

1.09

2819

 

752

0.86

 

 

 

 

 

 

0.7

3453

891

1.5

3094

846

1.18

 

 

 

 

 

 

 

 

 

 

 

 

 

0.9

2964

896

1.29

2524

852

0.96

 

 

 

 

 

 

 

 

 

 

 

 

 

1.1

2537

902

1.08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPG102 STANDARD BELT DRIVE HORIZONTAL

ESP, In

 

 

 

 

 

 

 

 

TURNS OPEN

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

2

 

 

 

3

 

 

4

 

 

5

 

H2O

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

 

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

3231

700

0.96

2928

656

0.75

0.3

 

 

 

 

 

 

3410

793

1.23

3121

 

744

0.99

2796

700

0.79

 

 

 

0.5

 

 

 

3342

838

1.33

3009

796

1.06

2669

 

749

0.83

 

 

 

 

 

 

0.7

3303

888

1.47

2944

843

1.15

 

 

 

 

 

 

 

 

 

 

 

 

 

0.9

2814

893

1.26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPG120 STANDARD BELT DRIVE HORIZONTAL

ESP, In

 

 

 

 

 

 

 

 

TURNS OPEN

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

2

 

 

 

3

 

 

4

 

 

5

 

H2O

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

 

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

 

 

 

 

 

 

 

4391

 

737

1.48

4054

693

1.22

3760

645

0.97

0.4

 

 

 

 

 

 

4314

781

1.61

3969

 

737

1.29

3534

693

1

 

 

 

0.6

 

 

 

4255

826

1.69

3894

781

1.38

3447

 

743

1.09

 

 

 

 

 

 

0.8

4234

876

1.85

3792

832

1.47

 

 

 

 

 

 

 

 

 

 

 

 

 

1

3724

877

1.59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPG150 STANDARD BELT DRIVE HORIZONTAL

 

0 TURNS

1 TURN

2 TURNS

3 TURNS

4 TURNS

5 TURNS

ESP (IN

 

 

 

 

 

 

 

 

 

 

 

 

W.C.)

CFM

BHP

CFM

BHP

CFM

BHP

CFM

BHP

CFM

BHP

CFM

BHP

0.2

5762

3.08

5485

2.63

5140

2.21

4855

1.84

4513

1.48

4197

1.20

0.4

5550

2.91

5207

2.44

4857

2.03

4489

1.64

4100

1.29

 

 

0.6

5202

2.65

4922

2.25

4487

1.81

4113

1.45

 

 

 

 

0.8

4898

2.43

4515

1.99

4074

1.58

 

 

 

 

 

 

1.0

4549

2.20

4135

1.76

 

 

 

 

 

 

 

 

1.2

4258

2.01

 

 

 

 

 

 

 

 

 

 

NOTE: High Static airflow requires installation of High Static Kit (HSKT*), or factory-built High Static model. Unit factory shipped at 2.5 turns open.

Tables represent dry coil without filter. To compensate for filter, add 0.08" to measured E.S.P. SCFM correction for wet coil = 4%.

24

Image 24
Contents Recognize this Symbol AS a Safety Precaution Replacement Parts Safety InstructionsHigh Voltage General InformationUnit Location Electrical Entrance Locations Roof Curb POST-INSTALLATION Checks Roof Curb InstallationClearances Roof TOP Duct ConnectionsRigging Details Horizontal Discharge Duct ConnectionsElectrical Wiring Corner & Center of Gravity LocationsPower and LOW Voltage Block Locations GAS Supply Piping CPG 090 Through 300 GAS HeatNatural Gas Connection Proper Piping PracticePropane GAS Installations Typical Propane GAS PipingSTARTUP, ADJUSTMENTS, and Checks Circulating AIR and FiltersVenting Condensate Drain Connection Drain ConnectionMoving Machinery Hazard Drive Belt Tension Adjustment Recommended Pounds of Force PER BeltRollout Protection Control Manifold Pressure Check Burn Hazard Heat Exchanger and Burner Orifice Specifications Normal Sequence of OperationTroubleshooting Check rollout limitAIR Flow Adjustments Motor Sheave AdjustmentsWHITE-RODGERS 36H54 Pressure Adjustments Input RatingMaintenance Burner Flame CPG090 Standard Belt Drive Horizontal CPG090 Standard Belt Drive Down Shot CPG090 High Static Belt Drive Down Shot Appendix B Electrical Data Horizontal Discharge Vertical Discharge Bottom of Unit0140L00550 REV a INSTALLER/SERVICEMAN 0140L00552 REV B 208-240/3/60 0140L00553 REV B
Related manuals
Manual 56 pages 48.63 Kb

CPG SERIES specifications

Goodman Manufacturing has long been a trusted name in the HVAC industry, known for delivering reliable and efficient heating and cooling solutions. Among its impressive lineup is the CPG series, a collection of packaged units that cater to a wide range of residential and commercial applications. The CPG series is designed with the latest technologies and features, making it an ideal choice for those seeking comfort and performance.

One of the most significant characteristics of the CPG series is its energy efficiency. Engineered to meet rigorous energy standards, these units utilize advanced refrigerant technologies that not only lower energy consumption but also contribute to reducing environmental impact. The high-efficiency scroll compressor within the CPG series is designed to operate quietly and smoothly, ensuring that homeowners enjoy a comfortable indoor environment without disruptive noise.

The CPG series also stands out with its robust construction. Each unit is crafted from durable materials that can withstand various weather conditions, ensuring longevity and reliability. The all-aluminum evaporator coil enhances corrosion resistance, prolonging the unit's lifespan and maintaining optimal performance throughout its operation.

In terms of features, the CPG series offers an integrated microprocessor control system that optimizes performance based on real-time environmental data. This smart technology allows for accurate temperature control and improved efficiency by adapting to changing conditions. Furthermore, the series provides multiple capacity options, making it flexible for various building sizes and requirements.

Ease of installation and maintenance is another hallmark of the CPG series. These packaged units are designed for quick setup, reducing labor costs and installation time. Additionally, the access panels on the units are strategically placed, facilitating easier maintenance and servicing. This advantage not only enhances user convenience but also ensures that the units operate efficiently for years to come.

Moreover, the CPG series supports various accessories and enhancements, such as advanced filtration systems and programmable thermostats, allowing users to customize their HVAC system based on specific needs and preferences.

In conclusion, the Goodman CPG series embodies a perfect blend of efficiency, durability, and technology. With its focus on energy savings and user-friendly design, it represents a sound investment for those seeking superior HVAC solutions for their homes or commercial spaces. Whether it's for new construction or an upgrade to an existing system, the CPG series offers performance and reliability that customers can depend on.