Goodman Mfg CPG SERIES installation instructions CPG090 Standard Belt Drive Down Shot

Page 25

APPENDIX A BLOWER PERFORMANCE DATA

BELT DRIVE - STANDARD DOWN SHOT

CPG090 STANDARD BELT DRIVE DOWN SHOT

ESP, In

 

 

 

 

 

 

 

 

TURNS OPEN

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

2

 

 

 

3

 

 

4

 

 

5

 

H2O

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

 

 

 

 

 

 

 

 

 

3522

 

750

1.14

3228

706

0.94

2964

661

0.73

0.3

 

 

 

 

 

 

3337

800

1.19

3102

 

756

1

2800

706

0.76

2504

661

0.59

0.5

 

 

 

3387

844

1.32

2834

806

0.99

2603

 

757

0.8

 

 

 

 

 

 

0.7

3453

893

1.5

2903

850

1.12

 

 

 

 

 

 

 

 

 

 

 

 

 

0.9

2957

899

1.29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPG102 STANDARD BELT DRIVE DOWN SHOT

ESP, In

 

 

 

 

 

 

 

 

TURNS OPEN

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

2

 

 

 

3

 

 

4

 

 

5

 

H2O

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

 

 

 

 

 

 

 

 

 

3372

 

747

1.11

3078

703

0.91

2814

658

0.70

0.3

 

 

 

 

 

 

3187

797

1.16

2952

 

753

0.97

2650

703

0.73

 

 

 

0.5

 

 

 

3237

841

1.29

2684

803

0.96

2453

 

754

0.77

 

 

 

 

 

 

0.7

3303

890

1.47

2753

847

1.09

 

 

 

 

 

 

 

 

 

 

 

 

 

0.9

2807

896

1.26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPG120 STANDARD BELT DRIVE DOWN SHOT

ESP, In

 

 

 

 

 

 

 

 

TURNS OPEN

 

 

 

 

 

 

 

 

 

0

 

 

1

 

 

2

 

 

 

3

 

 

4

 

 

5

 

H2O

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

CFM

 

RPM

BHP

CFM

RPM

BHP

CFM

RPM

BHP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2

 

 

 

 

 

 

4316

780

1.57

4118

 

738

1.36

3771

687

1.08

3376

644

0.85

0.4

 

 

 

4282

830

1.76

3928

786

1.4

3595

 

740

1.13

 

 

 

 

 

 

0.6

4232

874

1.87

3872

830

1.52

3444

786

1.2

 

 

 

 

 

 

 

 

 

 

0.8

3839

880

1.64

3367

836

1.27

 

 

 

 

 

 

 

 

 

 

 

 

 

1

3326

885

1.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPG150 STANDARD BELT DRIVE DOWN SHOT

 

0 TURNS

1 TURN

2 TURNS

3 TURNS

4 TURNS

5 TURNS

ESP (IN

 

 

 

 

 

 

 

 

 

 

 

 

W.C.)

CFM

BHP

CFM

BHP

CFM

BHP

CFM

BHP

CFM

BHP

CFM

BHP

0.2

5514

2.92

5604

3.22

5064

2.16

4775

1.81

4514

1.49

4271

1.23

0.4

5279

2.74

5110

2.40

4696

1.94

4447

1.63

4123

1.31

 

 

0.6

5185

2.67

4813

2.20

4352

1.74

4039

1.43

 

 

 

 

0.8

4766

2.37

4526

2.02

 

 

 

 

 

 

 

 

1.0

4223

2.01

 

 

 

 

 

 

 

 

 

 

NOTE: High Static airflow requires installation of High Static Kit (HSKT*), or factory-built High Static model. Unit factory shipped at 2.5 turns open.

Tables represent dry coil without filter. To compensate for filter, add 0.08" to measured E.S.P. SCFM correction for wet coil = 4%.

25

Image 25
Contents Recognize this Symbol AS a Safety Precaution Safety Instructions Replacement PartsGeneral Information High VoltageUnit Location Electrical Entrance Locations Roof Curb Installation Roof Curb POST-INSTALLATION ChecksClearances Roof TOP Duct ConnectionsHorizontal Discharge Duct Connections Rigging DetailsCorner & Center of Gravity Locations Electrical WiringPower and LOW Voltage Block Locations CPG 090 Through 300 GAS Heat GAS Supply PipingProper Piping Practice Natural Gas ConnectionTypical Propane GAS Piping Propane GAS InstallationsCirculating AIR and Filters STARTUP, ADJUSTMENTS, and ChecksVenting Condensate Drain Connection Drain ConnectionMoving Machinery Hazard Recommended Pounds of Force PER Belt Drive Belt Tension AdjustmentRollout Protection Control Manifold Pressure Check Burn Hazard Normal Sequence of Operation Heat Exchanger and Burner Orifice SpecificationsCheck rollout limit TroubleshootingMotor Sheave Adjustments AIR Flow AdjustmentsWHITE-RODGERS 36H54 Pressure Adjustments Input RatingMaintenance Burner Flame CPG090 Standard Belt Drive Horizontal CPG090 Standard Belt Drive Down Shot CPG090 High Static Belt Drive Down Shot Appendix B Electrical Data Vertical Discharge Bottom of Unit Horizontal Discharge0140L00550 REV a INSTALLER/SERVICEMAN 0140L00552 REV B 208-240/3/60 0140L00553 REV B
Related manuals
Manual 56 pages 48.63 Kb

CPG SERIES specifications

Goodman Manufacturing has long been a trusted name in the HVAC industry, known for delivering reliable and efficient heating and cooling solutions. Among its impressive lineup is the CPG series, a collection of packaged units that cater to a wide range of residential and commercial applications. The CPG series is designed with the latest technologies and features, making it an ideal choice for those seeking comfort and performance.

One of the most significant characteristics of the CPG series is its energy efficiency. Engineered to meet rigorous energy standards, these units utilize advanced refrigerant technologies that not only lower energy consumption but also contribute to reducing environmental impact. The high-efficiency scroll compressor within the CPG series is designed to operate quietly and smoothly, ensuring that homeowners enjoy a comfortable indoor environment without disruptive noise.

The CPG series also stands out with its robust construction. Each unit is crafted from durable materials that can withstand various weather conditions, ensuring longevity and reliability. The all-aluminum evaporator coil enhances corrosion resistance, prolonging the unit's lifespan and maintaining optimal performance throughout its operation.

In terms of features, the CPG series offers an integrated microprocessor control system that optimizes performance based on real-time environmental data. This smart technology allows for accurate temperature control and improved efficiency by adapting to changing conditions. Furthermore, the series provides multiple capacity options, making it flexible for various building sizes and requirements.

Ease of installation and maintenance is another hallmark of the CPG series. These packaged units are designed for quick setup, reducing labor costs and installation time. Additionally, the access panels on the units are strategically placed, facilitating easier maintenance and servicing. This advantage not only enhances user convenience but also ensures that the units operate efficiently for years to come.

Moreover, the CPG series supports various accessories and enhancements, such as advanced filtration systems and programmable thermostats, allowing users to customize their HVAC system based on specific needs and preferences.

In conclusion, the Goodman CPG series embodies a perfect blend of efficiency, durability, and technology. With its focus on energy savings and user-friendly design, it represents a sound investment for those seeking superior HVAC solutions for their homes or commercial spaces. Whether it's for new construction or an upgrade to an existing system, the CPG series offers performance and reliability that customers can depend on.