White Rodgers 1F97-0671 Change Filter time in 25 hour increments. This, Timer On/OFF, Heat On b

Page 6

INSTALLER/CONFIGURATION MENU

21

MENU

Change Filter (OFF)

On

Selects Filter Change-out Indicator On or OFF.

 

 

 

 

 

 

MENU

Change Filter (200 h)

25-1975 h

Change Filter time in 25 hour increments. This

 

 

 

 

menu only appears if On is selected in above.

 

 

 

 

 

22

MENU

(OFF)

On

Selects UV Lamp

 

 

Change UV Lamp

 

Timer: On/OFF

 

 

 

 

 

 

MENU

(350)

25-1975

Selects number of Days between changing UV

 

 

Change UV Lamp

 

Lamp

 

 

 

 

 

23

MENU

Cool On (o)

Heat On (b)

Selects operation of the reversing valve terminal

 

 

 

 

(O/B) output as an O or B terminal

 

 

 

 

 

24

MENU

RUN SCHED

 

Returns to Normal Operation

 

 

 

 

 

1)GAS or Electric (ELE) fan operation. If the heating system requires the thermostat to energize the fan, select ELE. Select GAS if the heating system energizes the fan on a call for heat.

2)Select Cool Savings™ – Cool Savings allows you to select a temperature offset (from 1-6 degrees). When the compressor runs for long periods, the thermostat will internally slowly/gradually adjust the room temperature display lower, subtracting a maximum of the number of degrees you select.

This energy saving feature is based on the principal that long compressor run times lower indoor humidity and make slightly higher temperature feel comfortable. Cool Savings operates only when the compressor runs 20 minutes or longer, normally on the hottest summer days. When Cool Savings is operating the thermostat will fl ash "Cool Savings" to indicate it is slowly adjusting the dis- play temperature lower.

To turn this feature on in the Cool mode press Cool Savings. The display will show “Save” next to the set- point temperature. When Cool Savings is making adjust- ments to the room temperature display “Save” will be

fl ashing and the displayed room temperature may vary within the adjustment range you selected.

If "Save" is not displayed and this feature is OFF, no change will occur when the cooling system is continuously running during periods of high demand.

3)Energy Management Recovery: (this step is skipped if configured to be non-programmable).

Energy Management Recovery (E) On enables the ther- mostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint.

Example: E On is selected and your heating is pro- grammed to 65° at night and 70° at 7 AM. If the building temperature is 65°, the difference between 65° and 70° is 5°. Allowing 5 minutes per degree, the thermostat setpoint will change to 70° at 6:35 AM. Cooling allows more time per degree, because it takes longer to reach set tempera- ture.

4 & 5) Cycle Rate Selection – The factory default setting for Heat and Cool modes is medium cycle (ME). To change

cycle rate, press the or button.

Cycle rate differentials for different settings are:

MODE

Fast

Medium

Slow

 

FA

ME

SL

Heat (SS1, MS2)

0.4°F

0.6°F

1.7°F

Cool (SS1, MS2)

0.9°F

1.2°F

1.7°F

6)Select Compressor Lockout CL OFF or ON – Selecting CL ON will cause the thermostat to wait 5 minutes be- tween cooling cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay occurs, it will fl ash the setpoint for up to five minutes.

7)System Mode Configuration – This thermostat is config- ured for Heat and Cool (SYSTEM switch with Cool Off Heat) default. It can also be configured for Heat and Cool with Auto changeover (Heat, Auto, Cool, Off), Heat only with fan (Off Heat), Heat only without fan, Auto only (Auto Off), and Cool only (Cool Off).

8)Select Backlight Display – The display backlight improves display contrast in low lighting conditions. When the "C" terminal is powered, selecting backlight CdL ON will keep the light on continuously. Select backlight OFF will turn the light on momentarily after any button is pressed. When the "C" terminal is not powered, the light will be on momentarily after any button is pressed no matter whether the backlight is selected ON or OFF.

9)Select Temperature Display Adjustment 4 LO to 4 HI – Allows you to adjust the room temperature display up to 4° higher or lower. Your thermostat was accurately calibrated at the factory, but you have the option to change the dis- play temperature to match your previous thermostat. The current or adjusted room temperature will be displayed.

10)Select F° or C° Readout – Changes the display readout to Celsius or Fahrenheit as required.

11)Select Audio Prompting (Beeper) On or Off – Factory default setting is on (b, On). If you wish to turn off the beeper select OFF.

12)Program Options: Selects confi guration for 7 day (7) or 5/1/1 day (3) programming or non-programming (0) mode. The default setting is 7, indicating 7 day programming.

The programs per week can be changed to 3 or 0 by

pressing the or buttons. A selection of 0 days for non-programmable will eliminate the need for EMR, and that step in the menu will be skipped.

13)Program Steps per day – This control can be confi gured for 4 or 2 program steps per day. Default is "2 PS" and can be toggled between 4 PS and 2 PS.

14 & 15) Select Automatic Schedule – 1F97 only, with just one touch of the Auto Schedule key this feature allows you to program a desired comfort temperature into all the program periods along with a 6° set back for night periods of both Heat and Cool programs. Factory default is "On" for both. When Heat AS On and Cool AS On are acti- vated while in Heat or Cool mode, select desired setpoint

6

Image 6
Contents Save these instructions for future use SpecificationsApplications Thermostat Application GuideBattery Location InstallationInstalling New Thermostat Power Stealing SwitchesTerminal Designation Descriptions Wiring ConnectionsWiring Diagrams Terminal Designation DescriptionThermostat Quick Reference Home Screen DescriptionProgramming and Configuration Items INSTALLER/CONFIGURATION Menu Menu only appears if On is selected in above Timer On/OFFChange Filter time in 25 hour increments. This Heat On bRecord the number you select for future use Factory default is Loc On. You can make it Loc Off if youPress Menu after selecting the type of lockout Or buttonOperating Your Thermostat Planning Your Program Important ProgrammingEnergy Saving Factory Pre-Program Worksheet for Re-Programming 5+1+1 and 7 Day ProgramProgramming Tip Copy Program Set Current Time and DayAutomatic Daylight Saving Calculation Enter the Heating ProgramWired Remote Temperature Sensing Entering Fan ProgramWeighing of Remote Reading Symptom Possible Cause Corrective Action TroubleshootingReset Operation St. Louis, Missouri Markham, Ontario

1F97-0671 specifications

The White Rodgers 1F97-0671 is a sophisticated thermostat designed to enhance the comfort and efficiency of residential heating and cooling systems. This programmable thermostat stands out in the market due to its user-friendly interface and advanced features, which cater to the diverse needs of modern households.

One of the standout characteristics of the 1F97-0671 is its intuitive touch-screen display. The large, easy-to-read screen allows users to access and adjust settings effortlessly. The bright and responsive interface is designed for clarity, making it convenient to program heating and cooling schedules, monitor current temperatures, and view system alerts.

Programmability is where the 1F97-0671 truly excels. With the ability to create up to seven customizable schedules per week, users can optimize their energy usage and maintain comfort levels at all times. This feature allows homeowners to set different temperatures for various times of the day, ensuring energy efficiency while keeping their living spaces comfortable when they are home.

In addition to its scheduling capabilities, the 1F97-0671 incorporates advanced technology to control both heating and cooling systems, including conventional and heat pump configurations. This versatility makes it compatible with a wide range of HVAC systems, allowing more homeowners to benefit from its features. Moreover, the thermostat includes an auto changeover function, which automatically switches between heating and cooling based on the indoor temperature.

The 1F97-0671 also includes smart features like energy usage reports, which help users understand their energy consumption patterns. By analyzing this data, homeowners can make informed decisions about their heating and cooling habits, ultimately leading to reduced energy bills and a lower environmental impact.

Installation is a breeze, thanks to the thermostat's compatibility with most existing wiring, and the included step-by-step instructions. Additionally, the device can be integrated into smart home systems, allowing remote access and control through compatible smart devices, enhancing its user-friendliness.

Overall, the White Rodgers 1F97-0671 is a feature-rich thermostat that combines efficiency, ease of use, and advanced technology. Its programmable options, user-friendly interface, and broad compatibility make it an excellent choice for homeowners looking to improve their energy management while ensuring consistent comfort in their living spaces.