OPERATING YOUR THERMOSTAT

Check Thermostat Operation

NOTE

To prevent static discharge problems, touch side of thermostat to release static build-up before touching any keys.

If at any time during testing your system does not operate properly, contact a qualifi ed service person.

Fan Operation

If your system does not have a G terminal connection, skip to

Heating System.

1.Turn on power to system.

2.Press FAN button to select ON. The blower should begin to operate.

3.Press FAN button to select AUTO. The blower should stop immediately.

!CAUTION

Do not allow the compressor to run unless the com- pressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes.

Heating System

1.Press SYSTEM button to select Heat. If the auxiliary heating system has a standing pilot, be sure to light it.

2.Press to adjust thermostat setting to 1° above room temperature. The heat pump system should begin to oper- ate. The display should show “System On” (see Confi gu- ration menu, item 11).

3.Press to adjust the thermostat below room tempera- ture. The heating system should stop operating.

!CAUTION

To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.

Cooling System

1.Press SYSTEM button to select Cool.

2.Press to adjust thermostat setting below room tem- perature. The blower should come on immediately on high speed, followed by cold air circulation. The display should show “System On”. If the setpoint temperature display is fl ashing, the compressor lockout feature is operating (see Confi guration menu, item 5).

3.Press to adjust the temperature setting above room temperature. The cooling system should stop operating.

Choose the Fan Setting (Auto or On)

Fan Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on.

Fan On selection runs the fan continuously for increased air circulation or to allow additional air cleaning.

Fan Prog On indicates that the fan is programmed to be on for the entire period. The Prog Fan On can be overridden to have the fan cycle with the system. Press the FAN but- ton to change the fan to Auto. The fan programming will be overridden until the next program period begins or until Run Schedule is pressed.

Choose the System Setting

(Cool, Off, Heat, Auto)

Press the SYSTEM button to select:

Heat: Thermostat controls only the heating system.

Off: Heating and Cooling systems are off.

Cool: Thermostat controls only the cooling system.

Auto: Auto Changeover is used in areas where both heating and cooling may be required on the same day. AUTO allows the thermostat to automatically select heating or cooling depending on the indoor temperature and the selected heat and cool temperatures. When using AUTO, be sure to set the Cooling temperatures more than 1° Fahrenheit higher than the heating temperature.

Manual Operation for

Non-Programmable Mode

Press the SYSTEM button to select Heat or Cool and use the buttons to adjust the temperature to your desired setting. After selecting your desired settings you can also press the SYSTEM button to select AUTO to allow the thermostat to automatically change between Heat and Cool.

Manual Operation (Bypassing the Program) Programmable Mode

Adjust the temperature wherever you like and then press the HOLD button. This will override the program. The HOLD feature bypasses the program and allows you to adjust the temperature manually, as needed. Whatever temperature you set in HOLD will be maintained 24 hours a day, until you manually change the temperature or press Run Schedule to cancel HOLD and resume the programmed schedule.

Program Override (Temporary Override)

Press buttons to adjust the temperature. This will override the temperature setting for a two hour override period.

Example: If you turn up the heat during the morning program, it will be automatically lowered later, when the temporary hold period ends. To cancel the temporary setting at any time and return to the program, press Run Schedule.

If the SYSTEM button is pressed to select AUTO the thermostat will change to Heat or Cool, whichever ran last. If it switches to heat, but you want cool, or it changes to cool, but you want heat, press both buttons simultaneously to change to the other mode.

8

Image 8
Contents Specifications ApplicationsSave these instructions for future use Thermostat Application GuideInstallation Installing New ThermostatBattery Location Power Stealing SwitchesWiring Connections Wiring DiagramsTerminal Designation Descriptions Terminal Designation DescriptionProgramming and Configuration Items Thermostat Quick ReferenceHome Screen Description INSTALLER/CONFIGURATION Menu Timer On/OFF Change Filter time in 25 hour increments. ThisMenu only appears if On is selected in above Heat On bFactory default is Loc On. You can make it Loc Off if you Press Menu after selecting the type of lockoutRecord the number you select for future use Or buttonOperating Your Thermostat Programming Energy Saving Factory Pre-ProgramPlanning Your Program Important Worksheet for Re-Programming 5+1+1 and 7 Day ProgramSet Current Time and Day Automatic Daylight Saving CalculationProgramming Tip Copy Program Enter the Heating ProgramWeighing of Remote Reading Wired Remote Temperature SensingEntering Fan Program Troubleshooting Reset OperationSymptom Possible Cause Corrective Action St. Louis, Missouri Markham, Ontario

1F97-0671 specifications

The White Rodgers 1F97-0671 is a sophisticated thermostat designed to enhance the comfort and efficiency of residential heating and cooling systems. This programmable thermostat stands out in the market due to its user-friendly interface and advanced features, which cater to the diverse needs of modern households.

One of the standout characteristics of the 1F97-0671 is its intuitive touch-screen display. The large, easy-to-read screen allows users to access and adjust settings effortlessly. The bright and responsive interface is designed for clarity, making it convenient to program heating and cooling schedules, monitor current temperatures, and view system alerts.

Programmability is where the 1F97-0671 truly excels. With the ability to create up to seven customizable schedules per week, users can optimize their energy usage and maintain comfort levels at all times. This feature allows homeowners to set different temperatures for various times of the day, ensuring energy efficiency while keeping their living spaces comfortable when they are home.

In addition to its scheduling capabilities, the 1F97-0671 incorporates advanced technology to control both heating and cooling systems, including conventional and heat pump configurations. This versatility makes it compatible with a wide range of HVAC systems, allowing more homeowners to benefit from its features. Moreover, the thermostat includes an auto changeover function, which automatically switches between heating and cooling based on the indoor temperature.

The 1F97-0671 also includes smart features like energy usage reports, which help users understand their energy consumption patterns. By analyzing this data, homeowners can make informed decisions about their heating and cooling habits, ultimately leading to reduced energy bills and a lower environmental impact.

Installation is a breeze, thanks to the thermostat's compatibility with most existing wiring, and the included step-by-step instructions. Additionally, the device can be integrated into smart home systems, allowing remote access and control through compatible smart devices, enhancing its user-friendliness.

Overall, the White Rodgers 1F97-0671 is a feature-rich thermostat that combines efficiency, ease of use, and advanced technology. Its programmable options, user-friendly interface, and broad compatibility make it an excellent choice for homeowners looking to improve their energy management while ensuring consistent comfort in their living spaces.