Heat & Glo LifeStyle FB-IN-S, FB-GRAND-S owner manual Inspect Maintenance Tasks

Page 33

Inspect

 

Maintenance Tasks

 

 

 

Doors, Surrounds

1.

Assess condition of screen and replace as necessary. Recommend addition of screen if one is not present.

and Fronts

 

 

2.

Inspect for scratches, dents or other damage and repair as necessary.

 

 

 

 

 

3.

Verify no obstructions to airflow through the louvers.

 

 

 

 

4.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Gasket Seal, Glass

1.

Inspect gasket seal and its condition.

Assembly and Glass

 

 

2.

Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.

 

 

 

 

 

3.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

4.

Verify that latches engage properly, clip studs are not stripped, and glass attachment components are

 

 

intact and operating properly. Replace as necessary.

 

5.

Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.

 

 

 

Valve Compartment

1.

Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screw

and Firebox Top

 

tips that have penetrated the sheet metal are sharp and should be avoided.

 

 

 

 

2.

Remove any foreign objects.

 

 

 

 

3.

Verify unobstructed air circulation.

 

 

 

Logs

1.

Inspect for broken, damaged, or missing logs. Replace as necessary.

 

 

 

 

2.

Verify correct log placement and no flame impingement causing sooting. Correct as necessary.

 

 

 

Firebox

1.

Inspect for paint condition, warpage, corrosion or perforation. Contact Dealer for inspection.

 

 

 

 

2.

Replace appliance if firebox has been perforated.

 

 

 

Burner Ignition and

1.

Verify burner is properly secured and aligned with pilot or igniter.

Operation

 

 

2.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

 

 

 

 

 

3.

Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.

 

 

 

 

4.

Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

 

 

 

 

5.

Inspect for lifting or other flame problems.

 

 

 

 

6.

Verify air shutter is clear of dust and debris.

 

 

 

 

7.

Inspect orifice for soot, dirt or corrosion.

 

 

 

 

8.

Verify manifold and inlet pressures. Adjust regulator as required.

 

 

 

 

9.

Inspect pilot flame strength. Clean or replace orifice as necessary.

 

 

 

 

10.

Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emery

 

 

cloth or replace as required.

 

 

 

11. Verify millivolt output. Replace as necessary.

 

 

 

Venting

1.

Inspect venting for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions, decks, fences or

 

 

sheds) has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remains intact.

 

 

 

 

6.

Inspect draft shield to verify it is not bent, damaged or missing.

 

 

 

Remote controls

1.

Verify operation of remote.

 

 

 

 

2.

Replace batteries in remote transmitters and battery-powered receivers.

 

 

 

 

3.

Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure

 

 

or leaking.

Heat & Glo • FB-IN-S, FB-GRAND-S783-910 Rev. D • 3/08

33

Image 33
Contents FB-GRAND-S FB-IN-S ModelsHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsInspect Appliance and Components Tools and Supplies NeededMinimum Fireplace Opening Fireplace Size RequirementsLocation Inches MillimetersClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsFire Risk Asphyxiation Risk Foot minimum in snow regionsVent Table Key Vent Information and DiagramsHorizontal Venting Measuring StandardsInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVenting Components Placing, Securing and Leveling the Appliance Masonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversions Gas Connection Gas InformationGas Pressures Minimum inlet pressureHigh Altitude Installations ON/OFF Switch Wiring the ApplianceElectrical Information Appliance RequirementsInstallation for Fan Optional Junction Box InstallationOptional Accessories Shock hazardFAN Junction BOX Installing Trim Surrounds FinishingMantel Projections Clean the Appliance Appliance SetupAccessories Ember PlacementLogs Locating Tabs Grate Assembly Heat & Glo FB-IN-S, FB-GRAND-S 783-910 Rev. D 3/08 Instructions Positioning the Logs Model FB-IN-SLOG PlacementFlat Spot for Log #4 Air Shutter Setting Glass AssemblyRemoving Glass Assembly Replacing Glass AssemblyOperating Instructions Before Lighting ApplianceBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceCheck Pilot Flame Appearance Initial Break-in ProcedureAfter Appliance is Lit Do not operate appliance with glass door removedFrequently Asked Questions Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionMaximum flame impingement. Follow lighting instruc Maintenance Tasks Maintaining and Servicing ApplianceRisk of injury or property damage Inspect Maintenance Tasks Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsPart number list on following At Depot Be ordered from an authorized dealerIncludes Pilot, Pilot Bracket and Air Passge Gaskets FB-IN-S NGKS-FBIN Stocked FB-GRAND-S, FB-IN-SLimited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyImportant operating Contact Information

FB-GRAND-S, FB-IN-S specifications

The Heat & Glo LifeStyle FB-IN-S and FB-GRAND-S are modern and innovative gas fireplace models that encompass style, comfort, and efficiency. Designed to enhance living spaces, these fireplaces provide both warmth and ambiance, making them a popular choice among homeowners and interior designers alike.

One of the standout features of these fireplaces is their sleek and contemporary design. The FB-IN-S model boasts a minimalist aesthetic that can seamlessly blend with various decor styles, while the FB-GRAND-S offers a more grand presence with its larger viewing area and elegant lines. Both models are constructed with high-quality materials that ensure durability and longevity, providing peace of mind for users.

In terms of technology, both fireplaces are equipped with advanced heating systems that deliver efficient warmth quickly and effectively. The high-performance burner design maximizes heat output while minimizing fuel consumption, resulting in lower energy bills and a reduced carbon footprint. Additionally, these models come with the unique IntelliFire ignition system, which allows for reliable and easy operation. With just the push of a button, users can enjoy instant warmth without the hassle of traditional wood-burning fireplaces.

The LifeStyle series also features customizable flame settings, allowing users to adjust the intensity and height of the flames to create the perfect ambiance for any occasion. The unique flame presentation technology creates a realistic and captivating fire display, enhancing the overall aesthetic of the living space.

Safety is a top priority for Heat & Glo, and both FB-IN-S and FB-GRAND-S models incorporate several safety features. The advanced safety shut-off system ensures that the fireplace operates safely and reliably, while the cool-to-the-touch glass front protects against accidental burns. Additionally, the fireplaces come with options for remote control operation, providing convenience and ease of use.

Another notable characteristic of these models is the wide range of venting options available, allowing for flexible installation in various home layouts. Homeowners can choose from direct vent or top vent configurations, making it easier to integrate the fireplace into any existing space.

In conclusion, the Heat & Glo LifeStyle FB-IN-S and FB-GRAND-S offer a perfect blend of style, technology, and safety. With their modern designs, efficient heating capabilities, customizable flame settings, and advanced safety features, these fireplaces are poised to enhance any home, making them a worthwhile investment for those seeking comfort and elegance in their living spaces.