Heat & Glo LifeStyle HST-42D owner manual Chimney Components, Catalog#

Page 44

B. Chimney Components

The following pictures show only those chimney compo- nents which may be safely used with this fireplace.

Catalog #

Description

CAK4A

Chimney Air Kit

ID4

Insulated Duct/Outside Air

UD4

Uninsulated Duct/Outside Air

12 in.

(305 mm)

5-1/4 in. (133 mm)

10-1/2 in.

(287 mm)

12in.

(305 mm)

4 in. (102 mm)

SL306

Chimney Section - 6 in. (152 mm) long

SL312

Chimney Section - 12 in. (305 mm) long

SL318

Chimney Section - 18 in. (457 mm) long

SL324

Chimney Section - 24 in. (610 mm) long

SL336

Chimney Section - 36 in. (914 mm) long

SL348

Chimney Section - 48 in. (1219 mm) long

SL3

Chimney Stabilizer

SL315

Chimney Offset/Return - 15 deg

SL330

Chimney Offset/Return - 30 deg

FS338

Ceiling Firestop - Straight

CAK4A Chimney Air Kit

ID4 Insulated Duct

4 in. (102 mm) i.d.

42 in.

(1067 mm)

UD4 Uninsulated Duct

FS339

Ceiling Firestop - 15 deg

FS340

Ceiling Firestop - 30 deg

AS8

SL300 Straight Attic Insulation Shield, 24 in. (610 mm)

JB877

Chimney Joint Band

42 in. (1067 mm)

4 in. (102 mm) i.d.

CB876

Chimney Bracket

RF370

Roof Flashing - Flat to 6/12 Pitch

RF371

Roof Flashing - 6/12 to 12/12 Pitch

TR344

Round Termination Cap

TR342

Round Telescoping Termination Cap

ST375

Square Termination Cap

TS345

Square Termination Cap

TS345P

Square Termination Cap - Painted

TCT375

Terra Cotta Termination Cap

DTO134

Short Octagon Decorative Cap

DTO146

Tall Octagon Decorative Cap

DTS134

Short Square Decorative Cap

DTS146

Tall Square Decorative Cap

 

 

CT35

Chase Top

 

 

LDS33

Decorative Shroud - 3 ft x 3 ft (.91 m x .91 m)

 

 

LDS46

Decorative Shroud - 4 ft x 6 ft (1.22 m x 1.83 m)

LDS-BV

Decorative Shroud - 26 in. x 26 in. (660 mm x 660 mm)

 

Field Constructed Shrouds (See “Woodburning Termination

 

Cap”)

CT-3A

Adapter - May be used with the following copper caps

 

CT-Series

 

 

 

DT-Series

 

A

8 in.

10-1/2 in.

(267 mm)

(203 mm)

 

 

B

 

Chimney Sections

 

 

A

B

 

Catalog#

in

m

in

m

SL306

6

152

43/4-

121

SL312

12

305

103/4-

273

SL318

18

457

163/4-

425

SL324

24

610

23/4-

578

SL336

36

914

343/-

83

SL348

48

1219

463/4-

187

A = Actual Length

 

 

 

 

B = Effective Length (length of

 

 

chimney part after it has

 

 

been snapped to another)

 

 

 

 

 

Inside

 

20-3/4 in.

Diameter

8 in.

 

(527 mm)

(203 mm)

4-3/4 in. (121 mm)

 

Outside

 

Diameter

Effective Height

 

10-1/2 in.

 

 

 

(267 mm)

SL3

Vent

Stabilizer

 

 

44

Heat & Glo • HST-42D • 27177 • Rev AG • 7/12

Image 44
Contents Fire Risk Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Number Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Warranty Hearth & Home Technologies Inc Limited Lifetime WarrantyWarranty Conditions This warranty is void ifListing and Code Approvals Appliance CertificationNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Seasoned Wood Starting a FireGrate FirescreenGlass Doors Outside Air optionalVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Maintenance and Service Chimney Inspection/CleaningDisposal of Ashes Creosote Formation and Need for RemovalGlass Cleaning Check Firebox RefractoryInspect Grate Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating Fireplace & Chimney Frequently open doors Central heat outlets or returnsInspect Fireplace and Components Tools and Supplies NeededFireplace System Requirements Framing & Clearances Select Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the FireplaceInstallation of Fireplace Things to ConsiderPosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Install Outside Air Kit AK14/AK18 InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleInstall Chimney Air Kit Assemble Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield Prepare Attic Insulation ShieldComplete Installation Install FlashingFollowing steps should be skipped if using a chase Cut out Hole in RoofChimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST375 Square Termination CapTS345/TS345P Square Termination Cap Shrouds Radiation ShieldField Constructed Shrouds Open Top Shroud TR342 caps require radiation shieldMailbox Style Shroud radiation shield required Roofed Style Shroud radiation shield required= 1/k x inches of thickness FinishingHearth Extension Finishing Material Non-combustible FacingCombustible Mantel MantelMm squares 4 in mm Accessories Gas Log/Lighter ProvisionWood Burning Inserts Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsChimney Components Catalog#14-1/2 10-7/8 276 mm Stocked Service PartsAt Depot Stocked 1415Do not Discard this Manual