13
The gas line should be installed by a qualified service technician.
Step 8
Gas Pressure
Requirements
•At the gas line access hole, use insulation to re- pack the space around the gas pipe.
•Insert insulation from the outside of the fireplace and pack the insulation tightly to totally seal between the pipe and the outer casing.
Figure 9. Gas Supply Line
Pressure requirements for
Pressure | Natural Gas | Propane |
|
|
|
Minimum | 5.0 inches | 11.0 inches |
Inlet Pressure | w.c. | w.c. |
|
|
|
Maximum Inlet | 14.0 inches | 14.0 inches |
Gas Pressure | w.c. | w.c. |
|
|
|
Manifold | 3.5 inches | 10.0 inches |
Pressure | w.c. | w.c. |
|
|
|
The tap for the manifold and inlet pressures are on the face of the gas control valve. Remove the control panel covering the valve. Use a small screwdriver to crack open the screw in the center of the tap. Position a rubber hose over the tap to obtain the pressure reading.
The fireplace and its individual
The fireplace must be isolated from the gas supply piping system by closing its individual