Heat & Glo LifeStyle Dakota 42H-B D. High Altitude Installations, Fire Risk Explosion Risk

Page 11
Fire Risk

Manual background WARNING

Fire Risk

Explosion Risk

Gas build-up during line purge may ignite.

Purge should be performed by qualified technician.

Ensure adequate ventilation.

Ensure there are no ignition sources such as sparks or open flames.

A small amount of air will be in the gas supply lines. When first lighting appliance it will take a short time for air to purge from lines. When purging is complete, the appliance will light and operate normally.

D. High Altitude Installations

U.L. listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 ft in the USA and Canada.

When installing this appliance at an elevation above 2000 ft, it may be necessary to decrease the input rating by chang- ing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 ft above a 2000 ft elevation in the U.S.A., or 10% for elevations between 2000 and 4500 ft in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the prop- er orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 ft (in Canada), check with local authorities.

Manual background WARNING

CHECK FOR GAS LEAKS

Fire Risk

Explosion Risk

Asphyxiation Risk

Check all fittings and connections.

Do not use open flame.

After the gas line installation is complete, all connections must be tightened and checked for leaks with a commercially available, non-corrosive leak check solution. Be sure to rinse off all leak check solution following testing.

Fittings and connections may have loosened during shipping and handling.

Manual background WARNING

Fire Risk

Explosion Risk

Do NOT change the valve settings.

This valve has been preset at the factory.

Changing valve settings may result in fire hazard or bodily injury.

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B4036-909 Rev C • 07/06

11

Image 11
Contents Models Dakota 42-B Dakota 42H-B This appliance must be installed outsideWhat to do if you smell gas Homeowner Reference Information Listing Label Information/LocationCongratulations 1 Listing and Code Approvals Table of Contents9 Appliance Setup 11 TroubleshootingB. Glass Specifications D. High Altitude Installations1 Listing and Code Approvals A. Appliance CertificationB. Tools and Supplies Needed A. Design and Installation Considerations2 Getting Started C. Inspect Appliance and ComponentsFire Risk Odor Risk 3 Framing and ClearancesA. Select Appliance Location Fire Risk¨ Figure 3.2 Framing Dimensions B. ClearancesC. Mantel Projections Framing DimensionsFP A 4 Termination LocationsA. Vent Termination Minimum Clearances A. Remove Logs and Shipping Cover 5 Appliance PreparationB. Securing and Leveling Appliance B. Gas Pressure 6 Gas InformationA. Fuel Conversion C. Gas ConnectionFire Risk Explosion Risk D. High Altitude InstallationsFire Risk Explosion Risk Fire Risk Explosion Risk Asphyxiation RiskWasher E. Valve Access7 Electrical Information A. Recommendation for WireC. Intellifire Ignition System Wiring B. Connecting to the ApplianceRoof or Overhang 8 FinishingA. Mantel Projections StructureFire Risk B. Facing MaterialFire Risk C. Positioning the Logs 9 Appliance SetupA. Clean the Appliance B.Grate Assembly Placementlog left side log and on top of front log Glass Specifications D. Glass AssemblyE. Placing Lava Rock SEVERE BURNS MAY RESULT 10 Operating InstructionsA. Before Lighting Appliance Fire Risk Burn Risk HOT! DO NOT TOUCHTurn off wall switch WARNING CAUTIONB. Lighting the Appliance FOR YOUR SAFETY READ BEFORE LIGHTINGIssue D. Frequently Asked QuestionsC. After the Appliance is Lit Initial Break-inProcedurePossible Causes 11 TroubleshootingA. Intellifire Ignition System SymptomRisk of injury or property damage 12 Maintaining and Servicing the ApplianceClean When cleaning glass doorTools Required A. Valve Service and ReplacementGround Wire Inspect B. Maintenance and Service TasksMaintenance Tasks 13 Reference Materials A. Appliance Dimension Diagram5 Right & 6 Left Door Assemblies Service Parts¨B. Service Parts List DAKOTA42-BSERIESDescription of Part Service PartsDAKOTA42-BSERIES Beginning Manufacturing Date 2/01/06 Service PartsExploded Parts Diagram DAKOTA42-BSERIESAlso available Service PartsDAKOTA42-BSERIES Description of PartBeginning Manufacturing Date 2/01/06 Service PartsService Parts List DAKOTA42-BSERIES# Description of Part Service PartsDAKOTA42-BSERIES This page intentionally left blank 20802 Kensington Blvd., Lakeville, MN C. WarrantyWARRANTY FOR HEAT & GLO LIFESTYLE COLLECTION FIREPLACESDO DISCARDNOT D. Contact Informationdealer with any questions or concerns DO NOT DISCARD THIS MANUAL