Heat & Glo LifeStyle Dakota 42-B Electrical Information, A. Recommendation for Wire, CSA C22.1

Page 13
7 Electrical Information

7 Electrical Information

A. Recommendation for Wire

Note: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code,

CSA C22.1.

C. Intellifire Ignition System Wiring

This appliance is equipped with an Intellifire control valve which operates on a 3 volt system.

This appliance is supplied with a battery pack which is located in the ON/OFF switch terminal box. A wiring diagram is shown in Figure 7.1.

The battery pack requires two D cell batteries (not included). See Section 12.B. for battery replacement.

B. Connecting to the Appliance

A. Recommendation for Wire WARNING

Shock Risk

Explosion Risk

Do NOT wire 110V to valve.

Do NOT wire 110V to wall switch

Incorrect wiring will damage millivolt values.

Incorrect wiring will override IPI safety lockout and may cause explosion.

Keep wire lengths short as possible by removing any excess wire length, not to exceed 18 ft.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

CAUTION

Battery polarity must be correct or module damage will occur.

CSA C22.1.WARNING

Shock Risk

Replace damaged wire with type 105° C rated wire.

Wire must have high temperature insulation.

CAUTION

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

 

 

IGNITION MODULE

 

I

 

 

 

 

3 VAC

 

 

INTERMITTENT

 

 

 

 

 

S

PILOT

 

 

 

 

 

IGNITOR

 

 

 

 

 

 

 

BATTERY

 

 

 

 

 

 

PACK

 

 

 

 

 

ON/OFF

 

 

 

 

 

 

WALL

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

FLAME SPARKER/

 

 

 

WHT

 

 

SENSOR

 

 

 

 

 

 

 

 

 

 

IGNITION

 

BATTERY

 

 

ORG

 

MODULE

 

 

 

 

 

(3V)

 

PACK

BLACK

 

GROUND TO

 

 

 

 

 

FIREPLACE

 

 

 

 

 

CHASSIS

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

VALVE

LOW VOLTAGE

 

BRN

BRN

 

 

 

SEE NOTE 1

 

ORG

 

 

 

 

GRN

 

 

 

PIGGYBACK

 

 

 

 

 

 

ON/OFF SWITCH

 

 

 

 

 

 

 

VALVE

 

Figure 7.1 Intellefire Pilot Ignition (IPI) Wiring Diagram

 

 

 

 

 

Heat & Glo LifeStyle Collection • Dakota 42-B/Dakota 42H-B4036-909 Rev C • 07/06

13

Image 13
Contents What to do if you smell gas This appliance must be installed outsideModels Dakota 42-B Dakota 42H-B Congratulations Listing Label Information/LocationHomeowner Reference Information 9 Appliance Setup Table of Contents11 Troubleshooting 1 Listing and Code Approvals1 Listing and Code Approvals D. High Altitude InstallationsA. Appliance Certification B. Glass Specifications2 Getting Started A. Design and Installation ConsiderationsC. Inspect Appliance and Components B. Tools and Supplies NeededA. Select Appliance Location 3 Framing and ClearancesFire Risk Fire Risk Odor RiskC. Mantel Projections B. ClearancesFraming Dimensions ¨ Figure 3.2 Framing DimensionsA. Vent Termination Minimum Clearances 4 Termination LocationsFP A B. Securing and Leveling Appliance 5 Appliance PreparationA. Remove Logs and Shipping Cover A. Fuel Conversion 6 Gas InformationC. Gas Connection B. Gas PressureFire Risk Explosion Risk D. High Altitude InstallationsFire Risk Explosion Risk Asphyxiation Risk Fire Risk Explosion RiskWasher E. Valve AccessC. Intellifire Ignition System Wiring A. Recommendation for WireB. Connecting to the Appliance 7 Electrical InformationA. Mantel Projections 8 FinishingStructure Roof or OverhangFire Risk B. Facing MaterialFire Risk A. Clean the Appliance 9 Appliance SetupB.Grate Assembly Placement C. Positioning the Logslog left side log and on top of front log E. Placing Lava Rock D. Glass AssemblyGlass Specifications A. Before Lighting Appliance 10 Operating InstructionsFire Risk Burn Risk HOT! DO NOT TOUCH SEVERE BURNS MAY RESULTB. Lighting the Appliance WARNING CAUTIONFOR YOUR SAFETY READ BEFORE LIGHTING Turn off wall switchC. After the Appliance is Lit D. Frequently Asked QuestionsInitial Break-inProcedure IssueA. Intellifire Ignition System 11 TroubleshootingSymptom Possible CausesClean 12 Maintaining and Servicing the ApplianceWhen cleaning glass door Risk of injury or property damageTools Required A. Valve Service and ReplacementGround Wire Maintenance Tasks B. Maintenance and Service TasksInspect 13 Reference Materials A. Appliance Dimension Diagram¨B. Service Parts List Service PartsDAKOTA42-BSERIES 5 Right & 6 Left Door AssembliesDAKOTA42-BSERIES Service PartsDescription of Part Exploded Parts Diagram Service PartsDAKOTA42-BSERIES Beginning Manufacturing Date 2/01/06DAKOTA42-BSERIES Service PartsDescription of Part Also availableService Parts List Service PartsDAKOTA42-BSERIES Beginning Manufacturing Date 2/01/06DAKOTA42-BSERIES Service Parts# Description of Part This page intentionally left blank WARRANTY FOR C. WarrantyHEAT & GLO LIFESTYLE COLLECTION FIREPLACES 20802 Kensington Blvd., Lakeville, MNdealer with any questions or concerns D. Contact InformationDO NOT DISCARD THIS MANUAL DO DISCARDNOT