Step 13. Lighting the Fireplace

You’ve reviewed all safety warnings, you’ve checked the fireplace for gas leaks, you know the vent system is unobstructed, and you’ve checked for faulty components. Now you’re ready to light the fireplace.

WARNING: PLEASE REFER TO THE USER’S

!MANUAL FOR ALL CAUTIONS, SAFETY, AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF THE FIREPLACE.

After the Installation

LEAVE THIS INSTALLATION MANUAL WITH

!THE APPLIANCE FOR FUTURE REFERENCE.

4Maintaining and Servicing Your Fireplace

Fireplace Maintenance

Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE.

Replacing old ember material

Frequency: Once annually, during the checkup.

By: Qualified service technician.

Task: Brush away loose ember material near the burner. Replace old ember material with new dime-size and shape pieces. Save the remaining ember material and repeat this procedure at your next servicing. For more information, see Placing Ember Material.

Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician.

Task: Brush or vacuum the control compartment, fireplace logs and burner areas surrounding the logs.

Cleaning Flame Sensor Rod (IPI Systems)

Frequency: Annually.

By: Qualified service technician.

Task: Make a visual check of the straight flame sensor rod (see Figure 33). Use emery cloth to carefully remove any existing film or white deposits.

Checking Flame Patterns, Flame Height

Frequency: Periodically.

By: Qualified service technician/Home owner.

Task: Make a visual check of your fireplace’s flame patterns. Make sure the flames are steady - not lifting or floating. See Figure 44. The flame sensor (IPI) or thermopile/ thermocouple (standing pilot) tips should be covered with flame. See Figure 33.

MAKE SURE THE FLAMES

ARE STEADY—NOT

LIFTING OR FLOATING.

Figure 44.

Burner Flame Patterns

Checking Vent System

Frequency: Before initial use and at least annually thereafter, more frequently if possible.

By: Qualified service technician/Home owner.

Task: Inspect the external vent cap on a regular basis to ensure that no debris is interfering with the flow of air. Inspect entire vent system for proper function.

Cleaning Glass Door

Frequency: After the first 3 to 4 hours of use. As neces- sary after initial cleaning.

By: Home owner.

Task: Remove and clean glass after the first 3 to 4 hours of use. After the initial cleaning, clean as necessary, particu- larly after adding new ember (flame colorant) material. Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner. NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners.

Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI383-901 Rev. K • 5/06

35

Image 35
Contents What to do if you smell gas Installation and OperationSafety and Warning Information Table of Contents 6000TR-OAK-IPI Log Set AssemblyLOGS-6OAK Service Parts List 6000TR-OAK, 6000TR-OAK-IPIIntermittent Pilot Ignition Valve Assembly6000TR-OAK Standing Pilot Ignition Valve AssemblyCertification Installation CodesHigh Altitude Installations Appliance CertificationManufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions ANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Fireplaces Diagram of the 6000TR-OAK, 6000TR-OAK-IPI Clearance Requirements Constructing the Fireplace ChaseLocating the Fireplace Framing the Fireplace Framing DimensionsDVP90ST Identifying Vent Components Installing the Vent SystemVent System Approvals Tems or Components MAY be UsedMAX .4 M Straight Up Vertical Venting Flue Restrictor InstructionsVertical Venting Chart Venting with One 90 Elbow Venting with ONE 1 90 ElbowVenting with Two 90 Elbows Venting with TWO 2 90 o ElbowsVenting with three 90 elbows Venting with Three 3 90 Elbows+ V 1 FT + H 1 FT Installing Vent Components Above the First 900 Elbow in the Venting System To Install the Heat ShieldInstall Support Brackets Continue Adding Vent Components12 Hole and Vent Pipe Horizontal Termination Vent TerminationAttic Firestop Minimum Clearances for Terminations Proper Positioning Leveling and Securing of a Fireplace Positioning, Leveling, and Securing the FireplaceStanding Pilot Ignition System Step Installing the Optional Heat-Zone-Gas KitVice Must be Wired Directly to the FIRE- Place Junction BOX Gas Control SystemsPressure Natural Gas Propane Gas Supply LineGas Pressure Requirements Wall Switch Wiring the FireplaceFor Standing Pilot Ignition Wiring Appliance Requirements Optional AccessoriesBRN Operation using Battery PowerSealant Material Hearth Extensions Finishing6000TR-OAK Tempered 6000TR-OAK-IPI Tempered Installing Trim, Logs, and Ember MaterialBefore Lighting the Fireplace Double-check for faulty componentsAir Shutter Setting Important Turn OFF the GAS Before Servicing Your Fireplace After the InstallationFireplace Maintenance Lighting the Fireplace

6000TR-OAK-IPI specifications

The Heat & Glo LifeStyle 6000TR-OAK-IPI is a modern gas fireplace designed to enhance the ambiance of any living space while providing efficiency and convenience. This model stands out for its innovative features and sleek design, making it a popular choice for homeowners looking to combine aesthetics with functionality.

One of the main features of the LifeStyle 6000TR-OAK-IPI is its realistic oak log set, which provides a traditional fireplace look without the hassle of wood. The logs are accentuated by a vibrant flame that can be adjusted to suit the user's preferences, ensuring a cozy atmosphere whether for a small gathering or a romantic evening.

The fireplace incorporates advanced technology, notably the Intellifire Ignition System (IPI). This system not only simplifies the ignition process but also enhances safety and energy efficiency. The IPI technology ensures that the fireplace ignites smoothly whenever needed and automatically shuts down when not in use, conserving gas and reducing costs.

Another significant characteristic of the LifeStyle 6000TR is its customizable design. Homeowners can choose from various trim and surround options, allowing the unit to blend seamlessly with different interior styles. The fireplace features a large viewing area, delivering a mesmerizing spectacle of flames that draws the eye and serves as a stunning focal point in any room.

Performance-wise, the LifeStyle 6000TR boasts an impressive heating capacity. With its powerful heat output, it can effectively warm a large area, making it perfect for open-concept living spaces. Furthermore, its efficient combustion system ensures that emissions are minimized, making it an environmentally friendly option.

Installation is made easier with the model's flexible venting options, allowing for both direct venting and vent-free configurations. Homeowners can select the installation method that best suits their heating needs and home design.

With a combination of style, efficiency, and modern technology, the Heat & Glo LifeStyle 6000TR-OAK-IPI is an exceptional choice for those looking to elevate their home heating experience. It blends warmth with aesthetic appeal, making it a worthwhile investment for any household.