Heat & Glo LifeStyle 6000TR-OAK-IPI owner manual Flue Restrictor Instructions, Vertical Venting

Page 16

CAP

STRAIGHT UP

VERTICAL VENTING

V (FT.)

40' MAX. (12.4 M)

V

NOTE: On vertical venting configurations over 10 feet install the flue restrictor (385-128). See flue restric- tor installation instructions.

Figure 6.

Straight Up Vertical Venting

Flue Restrictor Instructions

1.Remove Exhaust Shield using a 1/4” nut driver by removing the four screws securing it in place (see Figure 7).

EXHAUST

SHIELD

FLUE

RESTRICTOR

Figure 7

2.Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 8).

BREAK

HERE

Figure 8. Flue Restrictor

16

Heat & Glo • 6000TR-OAK, 6000TR-OAK-IPI383-901 Rev. K • 5/06

Image 16
Contents Installation and Operation What to do if you smell gasSafety and Warning Information Table of Contents Log Set Assembly 6000TR-OAK-IPIService Parts List 6000TR-OAK, 6000TR-OAK-IPI LOGS-6OAKValve Assembly Intermittent Pilot IgnitionStanding Pilot Ignition Valve Assembly 6000TR-OAKInstallation Codes High Altitude InstallationsAppliance Certification CertificationVent Directly BELOW. Keep Clear of ALL OB- Structions Requirements for the Commonwealth of MassachusettsManufacturer Requirements Introducing the Heat & Glo Gas Fireplaces Pre-install PreparationANY Such Action MAY Possibly Cause a Fire Hazard Diagram of the 6000TR-OAK, 6000TR-OAK-IPI Locating the Fireplace Constructing the Fireplace ChaseClearance Requirements Framing Dimensions Framing the FireplaceDVP90ST Installing the Vent System Vent System ApprovalsTems or Components MAY be Used Identifying Vent ComponentsVertical Venting Flue Restrictor InstructionsMAX .4 M Straight Up Vertical Venting Chart Venting with ONE 1 90 Elbow Venting with One 90 ElbowVenting with TWO 2 90 o Elbows Venting with Two 90 ElbowsVenting with Three 3 90 Elbows Venting with three 90 elbows+ V 1 FT + H 1 FT Installing Vent Components To Install the Heat Shield Install Support BracketsContinue Adding Vent Components Above the First 900 Elbow in the Venting System12 Hole and Vent Pipe Attic Firestop Vent TerminationHorizontal Termination Minimum Clearances for Terminations Positioning, Leveling, and Securing the Fireplace Proper Positioning Leveling and Securing of a FireplaceStep Installing the Optional Heat-Zone-Gas Kit Vice Must be Wired Directly to the FIRE- Place Junction BOXGas Control Systems Standing Pilot Ignition SystemGas Pressure Requirements Gas Supply LinePressure Natural Gas Propane Wiring the Fireplace For Standing Pilot Ignition Wiring Appliance RequirementsOptional Accessories Wall SwitchOperation using Battery Power BRNFinishing Sealant Material Hearth ExtensionsInstalling Trim, Logs, and Ember Material 6000TR-OAK Tempered 6000TR-OAK-IPI TemperedAir Shutter Setting Double-check for faulty componentsBefore Lighting the Fireplace After the Installation Fireplace MaintenanceLighting the Fireplace Important Turn OFF the GAS Before Servicing Your Fireplace