INSTALLATION

!WARNING

Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code.

Remove Old Thermostat

Before removing wires from old thermostat, mark wires for terminal identification so the proper connections will be made to the new thermostat.

Installing New Thermostat

1.Pull the thermostat body off the thermostat base. Forcing or prying on the thermostat will cause damage to the unit.

2.Place base over hole in wall and mark mounting hole locations on wall using base as a template.

3.Move base out of the way. Drill mounting holes. If you are using existing mounting holes and the holes drilled are too large and do not allow you to tighten base snug- ly, use plastic screw anchors to secure the base.

4.Fasten base snugly to wall using mounting holes shown in Figure 1 and two mounting screws. Leveling is for appearance only and will not affect thermostat operation.

5.Connect wires to terminal block on base using appropriate wiring schematic.

6.Push excess wire into wall and plug hole with a fire re- sistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

7.Carefully line the thermostat up with the base and snap into place.

Battery Location

2 "AA" alkaline batteries are included in the thermostat at the factory with a battery tag to prevent power drainage. Remove the battery tag to engage the batteries.

To replace batteries, set system to OFF, remove thermostat from wall and install the batteries in the rear along the top of the thermostat (see Figure 1). For best results, use a premi- um brand "AA" alkaline battery such as Duracell® or Ener- gizer®. If the home is going to be unoccupied for an extended

period (over 3 months) and is displayed, the batteries should be replaced before leaving.

Power Stealing Switch

The Power Stealing Switches (Fig. 1) should be left in the "On" position for most systems. The information in the fol- lowing table details the thermostat power method and switch options.

WIRING CONNECTIONS

Thermostat Power Method

Switch Position/Description

 

 

Battery Powered, no 24 Volt

Switches "On", thermostat runs

system power available.

on batteries.

 

 

Hardwired with Battery

Switches "On", thermostat

Back-up,for 24 Volt systems

runs on power directly from

with common connection from

transformer with battery back-

transformer to "C" terminal on

up.

thermostat.

 

 

 

*Battery Powered with Power

Switches "On", thermostat runs

Stealing Assist, for 24 Volt

on batteries and supplemental

systems with no common

power drawn through the heat

connection from transformer to

or cool circuit.

"C" terminal on thermostat.

 

 

 

*Power Stealing Assist is very reliable to increase battery life, but on a small number of heating or cooling systems with high impedance electronic modules you may observe one of the fol- lowing conditions:

1.The furnace draft inducer motor may run with no call for heat.

2.The furnace fan may turn on with no call for heat or may not turn off.

3.The furnace may not turn off when the call for heat ends.

4.The air conditioner may not turn off when the call for cool ends.

If the Power Stealing Assist method is not compatible with your system, place the Power Stealing Switches to "Off". This cancels Power Stealing Assist, operates the thermostat on batteries and corrects the condition.

Figure 1 – Thermostat Base Multi-Stage 1F95EZ-0671

Mounting

Mounting

Hole

Hole

Place Level

Place Level

across Mounting Tabs

across Mounting Tabs

(for appearance only)

(for appearance only)

Rear view of thermostat

 

2 "AA" Batteries

 

Power Stealing

*

Switches

 

* A1 For Damper Control Not Applicable To This Model.

Refer to equipment manufacturers' instructions for specific system wiring information. After wiring, see CONFIGURA- TION section for proper thermostat configuration.

Wiring diagrams shown are for typical systems and describe the thermostat terminal functions.

 

TERMINAL DESIGNATION DESCRIPTIONS

Terminal Designation

Description

 

 

O/B

Changeover valve for heat pump energized constantly in cooling and off/heating

Y2

2nd Stage Compressor

Y

Compressor Relay

G

Fan Relay

RC

Power for Cooling

RH

Power for Heating

C

Common wire from secondary side of cooling (Optional). Required for fault indication, continuous back-

 

light operation or remote temperature sensor operation 6 Powered closed 3rd wire for 3-wire zone valve

W/E

Heat Relay/Auxiliary Heat Relay (Stage 1) (3rd Stage Heat in HP2)

W2

2nd Stage Heat (4th Stage Heat in HP2)

L

Compressor diagnostic indicator for systems with diagnostic connection typically found on Heat pump

 

systems or with Copeland's Comfort Alert

 

 

2

Image 2
Contents Save these instructions for future use SpecificationsApplications Thermostat Application GuideInstallation Wiring ConnectionsHeat Pump Type 2 HP 2. Multi-stage Wiring DiagramsHeat Pump Type 1 HP 1. Single stage Programming and Configuration Items Thermostat Quick ReferenceHome Screen Description Hold Copy Menu identifies buttonINSTALLER/CONFIGURATION Menu Cating non-programming. The programs per week can be Or buttonOperating Your Thermostat Symptom Possible Cause Corrective Action TroubleshootingReset Operation Cycles Too Fast or Too Slow
Related manuals
Manual 8 pages 4.93 Kb

1F95EZ-0671 specifications

The White Rodgers 1F95EZ-0671 is an advanced programmable thermostat designed to offer convenience and control over home heating and cooling systems. It is an ideal choice for homeowners looking to optimize their energy usage while maintaining comfortable living conditions.

One of the standout features of the 1F95EZ-0671 is its user-friendly interface, which includes a large, easy-to-read touchscreen display. The intuitive design allows users to navigate through settings effortlessly, making it accessible for individuals of all ages. The display is backlit, ensuring visibility even in low light conditions, which adds to its ease of use.

This thermostat supports both heating and cooling systems, including conventional systems as well as heat pumps, making it versatile for various home setups. Its compatibility with 24V systems further enhances its appeal for homeowners looking to upgrade their existing thermostats without extensive modifications.

Another significant technological advancement in the 1F95EZ-0671 is its Wi-Fi connectivity. This feature allows users to control their home climate remotely via a smartphone app, providing unparalleled convenience. Whether at work or on vacation, users can adjust their home temperature settings, ensuring optimal comfort upon their return. The app also enables users to monitor energy usage, helping them make informed decisions about their heating and cooling practices.

Energy efficiency is a key focus of the 1F95EZ-0671. It features a 7-day programmable schedule, allowing users to set heating and cooling times based on their specific routines. By programming temperature changes for different times of the day, users can significantly reduce energy consumption and lower utility bills. The thermostat also includes a vacation mode, which temporarily overrides the regular schedule, further optimizing energy savings when the home is unoccupied.

Additionally, the 1F95EZ-0671 is equipped with Smart Alerts that notify users of extreme temperatures, helping to prevent potential problems and ensure a safe home environment. With its combination of advanced features and user-centric design, the White Rodgers 1F95EZ-0671 provides an effective solution for modern temperature control, making it a valuable addition to any home.