White Rodgers 1F95EZ-0671 specifications INSTALLER/CONFIGURATION Menu

Page 5

INSTALLER/CONFIGURATION MENU

With Heat or A/C selected, press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table

below. Press Menu to advance to the next menu item. Press or to change a menu item options.

INSTALLER/CONFIGURATION MENU

Menu

HP

SS

Press

Displayed

Press

or

to

Comments

Ref.

 

 

Button

(Factory Default)

select from listed op-

 

 

 

 

 

 

 

tions

 

 

 

 

 

 

 

 

 

1

1

1

MENU

(MS 2)

HP 1, HP 2, SS 1

Selects Multi-Stage (MS 2 No Heat Pump),

 

 

 

 

 

 

 

 

Heat Pump 1 (HP 1, 1 compressor),

 

 

 

 

 

 

 

 

Heat Pump 2 (HP 2, 2 compressor or 2 speed

 

 

 

 

 

 

 

 

compressor), or Single Stage (SS 1)

 

 

 

 

 

 

 

 

 

2

2

2

MENU

(GAS) for SS or MS

 

ELE

 

GAS setting: furnace controls the blower

 

 

 

 

 

 

 

 

ELE setting: thermostat controls the blower

 

 

 

 

 

 

 

 

 

3

3

3

MENU

E (On)

 

OFF

 

Selects Energy Management Recovery (EMR)

 

 

 

 

 

 

 

 

On or OFF. (Not available in -non-program-

 

 

 

 

 

 

 

 

mable mode)

 

 

 

 

 

 

 

 

 

4

4

MENU

CR Heat (ME)

 

SL, FA

 

Selects Adjustable Anticipation, cycle rate, Heat

 

 

 

 

 

 

 

 

(This item only appears when MS 2 or SS 1 is

 

 

 

 

 

 

 

 

selected above)

 

 

 

 

 

 

 

 

 

5

4

MENU

CR Heat A/C

 

SL, FA

 

Selects Adjustable Compressor Anticipation

 

 

 

 

(ME)

 

 

 

(Heat Pump) This item only appears when

 

 

 

 

 

 

 

 

HP 1, HP 2 is selected above

 

 

 

 

 

 

 

 

 

6

5

5

MENU

CR A/C (ME)

 

SL, FA

 

Selects Adjustable Anticipation, cycle rate, cool

 

 

 

 

or

 

 

 

(when MS 2 or SS 1 is selected above.) or

 

 

 

 

CR Aux Heat (FA)

 

SL

 

Selects the cycle rate for Auxiliary stage (when

 

 

 

 

 

 

 

 

HP 1 or HP 2 is selected above)

 

 

 

 

 

 

 

 

 

7

6

6

MENU

CL (OFF)

 

CL On

 

Compressor Lockout Time

 

 

 

 

 

 

 

 

8

7

7

MENU

Heat A/C Off

Heat A/C Off,

 

System Mode Configuration

 

 

 

 

or

Heat Off with Fan icon,

with Automatic Changeover capability

 

 

 

 

Aux Heat A/C Off

Heat Off without Fan icon

 

 

 

 

 

 

 

A/C Off

 

 

 

 

 

 

 

 

 

 

 

9

8

8

MENU

CO (OFF)

 

CO On

 

Selects Compressor Optimization

 

 

 

 

 

 

 

 

 

10

9

9

MENU

dL (On)

 

dL OFF

 

Selects Display Light On or OFF

 

 

 

 

 

 

 

11

10

10

MENU

0 HI

1 HI, 2 HI, 3HI, 4 HI,

Adjustable Ambient Temperature Display

 

 

 

 

(current temperature)

1 LO, 2 LO, 3 LO, 4 LO

 

 

 

 

 

 

 

 

 

 

12

11

11

MENU

°F

 

°C

 

Selects Fahrenheit/Celsius Temperature Display

 

 

 

 

 

 

 

 

 

13

12

12

MENU

P (0)

 

7

 

Defaults to P (0) non-programmable

 

 

 

 

 

 

 

 

P (7) is 7-day programming

 

 

 

 

 

 

 

 

 

14

13

13

MENU

PS (2)

 

4

 

Selects Program periods per day:

 

 

 

 

 

 

 

 

4 = Morn, Day, Eve, Night

 

 

 

 

 

 

 

 

2 = Day, Night

 

 

 

 

 

 

 

 

 

15

14

MENU

Heat FA (On)

 

OFF

 

Fast Heat option may be disabled by

 

 

 

 

 

 

 

 

selecting OFF. NA to SS or HP1 config.

 

 

 

 

 

 

 

 

 

16

15

14

MENU

A/C FA (On)

 

OFF

 

Fast Cool option may be disabled by

 

 

 

 

 

 

 

 

selecting OFF. NA to SS or HP1 config.

 

 

 

 

 

 

 

 

 

17

16

15

MENU

dS (On)

 

Off

 

Selects Automatic Daylight Saving Time option

 

 

 

 

 

 

 

 

 

18

17

16

MENU

HL Heat

 

62 to 98

 

Select's Limited HEAT Range

 

 

 

 

(99)

 

 

 

 

 

 

 

 

 

 

 

 

 

19

18

17

MENU

LL A/C

 

46 to 82

 

Select's Limited A/C Range

 

 

 

 

(45)

 

 

 

 

 

 

 

 

 

 

 

 

 

20

19

MENU

dF (0)

 

1 to 9

 

Selects dF (dual Fuel) setting. 0 is Off

 

 

 

 

 

 

 

 

(If dual Fuel option is required, a selection of 5

 

 

 

 

 

 

 

 

is recommended)

 

 

 

 

 

 

 

 

 

 

 

 

MENU

Cd

 

0 to 99

 

Selects compressor delay in seconds when dF

 

 

 

 

(60)

 

 

 

is greater than 0

 

 

 

 

 

 

 

 

21

20

18

MENU

A/C On (o)

Heat On (b)

 

Selects operation of the reversing valve terminal

 

 

 

 

 

 

 

 

(O/B) output as an O or B terminal

 

 

 

 

 

 

 

 

 

5

Image 5
Contents Applications SpecificationsSave these instructions for future use Thermostat Application GuideWiring Connections InstallationHeat Pump Type 2 HP 2. Multi-stage Wiring DiagramsHeat Pump Type 1 HP 1. Single stage Home Screen Description Thermostat Quick ReferenceProgramming and Configuration Items Hold Copy Menu identifies buttonINSTALLER/CONFIGURATION Menu Or button Cating non-programming. The programs per week can beOperating Your Thermostat Reset Operation TroubleshootingSymptom Possible Cause Corrective Action Cycles Too Fast or Too Slow
Related manuals
Manual 8 pages 4.93 Kb

1F95EZ-0671 specifications

The White Rodgers 1F95EZ-0671 is an advanced programmable thermostat designed to offer convenience and control over home heating and cooling systems. It is an ideal choice for homeowners looking to optimize their energy usage while maintaining comfortable living conditions.

One of the standout features of the 1F95EZ-0671 is its user-friendly interface, which includes a large, easy-to-read touchscreen display. The intuitive design allows users to navigate through settings effortlessly, making it accessible for individuals of all ages. The display is backlit, ensuring visibility even in low light conditions, which adds to its ease of use.

This thermostat supports both heating and cooling systems, including conventional systems as well as heat pumps, making it versatile for various home setups. Its compatibility with 24V systems further enhances its appeal for homeowners looking to upgrade their existing thermostats without extensive modifications.

Another significant technological advancement in the 1F95EZ-0671 is its Wi-Fi connectivity. This feature allows users to control their home climate remotely via a smartphone app, providing unparalleled convenience. Whether at work or on vacation, users can adjust their home temperature settings, ensuring optimal comfort upon their return. The app also enables users to monitor energy usage, helping them make informed decisions about their heating and cooling practices.

Energy efficiency is a key focus of the 1F95EZ-0671. It features a 7-day programmable schedule, allowing users to set heating and cooling times based on their specific routines. By programming temperature changes for different times of the day, users can significantly reduce energy consumption and lower utility bills. The thermostat also includes a vacation mode, which temporarily overrides the regular schedule, further optimizing energy savings when the home is unoccupied.

Additionally, the 1F95EZ-0671 is equipped with Smart Alerts that notify users of extreme temperatures, helping to prevent potential problems and ensure a safe home environment. With its combination of advanced features and user-centric design, the White Rodgers 1F95EZ-0671 provides an effective solution for modern temperature control, making it a valuable addition to any home.