White Rodgers 1F95EZ-0671 specifications Operating Your Thermostat

Page 7

OPERATING YOUR THERMOSTAT

Check Thermostat Operation

NOTE

To prevent static discharge problems, touch side of thermostat to release static build-up before touching any keys.

If at any time during testing your system does not operate properly, contact a qualified service person.

Fan Operation

If your system does not have a G terminal connection, skip to

Heating System.

1.Turn on power to system.

2.Press FAN button. The display will show "Fan" and the blower should begin to operate.

3.Press FAN button again. The display will show "Fan" out- lined and the blower should stop immediately.

!CAUTION

Do not allow the compressor to run unless the compressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes.

Heating System

1.Press the HEAT button to select HEAT. If the auxiliary heating system has a standing pilot, be sure to light it.

2.Press to adjust thermostat setting to 1° above room temperature. The heat pump system should begin to operate. The display should show “Heat”. However, if the system configuration is set to HP1 or HP2 and setpoint temperature display is flashing, the 5 minute compressor lockout feature is operating (see Configuration menu, item 7).

3.Adjust temperature setting to 3° above room temperature. If your system configuration is set at MS2, HP2 or HP1, the auxiliary heat system should begin to operate and the display will show "Aux" and "Heat".

4.Press to adjust the thermostat below room tempera- ture. The heating system should stop operating.

Auxiliary (Emergency) System

AUX bypasses the Heat Pump to use the heat source wired to terminal W/E on the thermostat. AUX is typically used when compressor operation is not desired, or you prefer back-up heat only.

1.Press and hold HEAT button for at least 5 seconds to select "AUX".

2.Press to adjust thermostat setting above room tem- perature. The Auxiliary heating system will begin to oper- ate. The display will show “AUX” and “HEAT”.

3.Press to adjust the thermostat below room tempera- ture. The Auxiliary heating system should stop operating.

4.To return to Heat Pump mode press “HEAT” button. "Aux" will dsplay.

!CAUTION

To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.

Cooling System

1.Press A/C button to select A/C.

2.Press to adjust thermostat setting below room tem- perature. The blower should come on immediately on high

speed, followed by cold air circulation. The display should show “A/C”. If the setpoint temperature display is flashing, the compressor lockout feature is operating (see Configu- ration menu, item 7).

3.Adjust temperature setting to 3° below room temperature. The second stage cooling should begin to operate. A click from the thermostat will be heard to confirm second stage.

4.Press to adjust the temperature setting above room temperature. The cooling system should stop operating.

Dual Fuel Temperature Setpoint and

Compressor Delay

When the thermostat is configured for Heat Pump mode and the Dual Fuel feature is selected, the thermostat can use software logic to determine when to switch to gas heat and shut down the compressor. This eliminates the need for a fossil fuel kit.

The user selectable temperature is called the dual fuel tem- perature setpoint (dF) and is set in the Installer/Configuration menu, item 20. A software logic based dual fuel number from 1 to 9 can be selected. A selection of 5 is recommended. A higher number will provide a larger stage separation. A lower number will provide a smaller separation.

After the dual fuel temperature setting is selected, press Menu. A compressor delay (Cd) can be set for compressor shutdown after the auxiliary stage is energized. This delay will minimize the time the system may blow cooler air until the alternate source of heat comes on. Default setting for delay is 60 seconds. This delay can be set from 0 to 99 seconds using

the or buttons.

Compressor Delay (Cd) will not be available if dF is selected 0 (off).

7

Image 7
Contents Thermostat Application Guide SpecificationsApplications Save these instructions for future useWiring Connections InstallationHeat Pump Type 1 HP 1. Single stage Wiring DiagramsHeat Pump Type 2 HP 2. Multi-stage Hold Copy Menu identifies button Thermostat Quick ReferenceHome Screen Description Programming and Configuration ItemsINSTALLER/CONFIGURATION Menu Or button Cating non-programming. The programs per week can beOperating Your Thermostat Cycles Too Fast or Too Slow TroubleshootingReset Operation Symptom Possible Cause Corrective Action
Related manuals
Manual 8 pages 4.93 Kb

1F95EZ-0671 specifications

The White Rodgers 1F95EZ-0671 is an advanced programmable thermostat designed to offer convenience and control over home heating and cooling systems. It is an ideal choice for homeowners looking to optimize their energy usage while maintaining comfortable living conditions.

One of the standout features of the 1F95EZ-0671 is its user-friendly interface, which includes a large, easy-to-read touchscreen display. The intuitive design allows users to navigate through settings effortlessly, making it accessible for individuals of all ages. The display is backlit, ensuring visibility even in low light conditions, which adds to its ease of use.

This thermostat supports both heating and cooling systems, including conventional systems as well as heat pumps, making it versatile for various home setups. Its compatibility with 24V systems further enhances its appeal for homeowners looking to upgrade their existing thermostats without extensive modifications.

Another significant technological advancement in the 1F95EZ-0671 is its Wi-Fi connectivity. This feature allows users to control their home climate remotely via a smartphone app, providing unparalleled convenience. Whether at work or on vacation, users can adjust their home temperature settings, ensuring optimal comfort upon their return. The app also enables users to monitor energy usage, helping them make informed decisions about their heating and cooling practices.

Energy efficiency is a key focus of the 1F95EZ-0671. It features a 7-day programmable schedule, allowing users to set heating and cooling times based on their specific routines. By programming temperature changes for different times of the day, users can significantly reduce energy consumption and lower utility bills. The thermostat also includes a vacation mode, which temporarily overrides the regular schedule, further optimizing energy savings when the home is unoccupied.

Additionally, the 1F95EZ-0671 is equipped with Smart Alerts that notify users of extreme temperatures, helping to prevent potential problems and ensure a safe home environment. With its combination of advanced features and user-centric design, the White Rodgers 1F95EZ-0671 provides an effective solution for modern temperature control, making it a valuable addition to any home.