THERMOSTAT QUICK REFERENCE
Home Screen Description
Figure 6 – Home Screen Display
Battery Level Indicator Indicating the current power level of the 2 “AA” batteries.
Full power remaining. Half power remaining.
Change The batteries should be replaced at this time with 2 new premium brand “AA” Alkaline batteries. (See page 2 for more details).
System
Indicators
Room Setting
Temperature Temperature
Menu, Copy,
or Hold Button
Sched or
RunSched
Button
Fan
Indicator
Heat | A/C or | OFF or | Fan or |
Button | Advance | Time | Run Button |
| Day Button | Button |
|
Figure 7 – Programming & Configuration Items
14
15
16
17
1
13 12 11 10
9
8
7
6
2 | 3 | 4 | 5 |
Programming and Configuration Items
1“Heat" “A/C” “Off” identifies button. When filled indi- cates system mode selected.
2"" indicates thermostat configured for Heat Pump. "Aux" indicates Auxiliary (Emergency) stage is selected.
3"Adv Day" identifies button when in schedule mode.
4"Time" identifies button when in schedule mode.
5"Fan" identifies button. When filled indicates Fan is on.
6"Run" identifies button to begin normal operation.
7"Sched" identifies button to be used during program- ming or "Run Sched" identifies button to return to normal operation.
8"Hold" "Copy" "Menu" identifies button.
9"Limit" indicates temperature is adjusted to the limit set in the configuration menu.
10"Setting" indicates the setpoint temperature.
11"Hold Temp" indicates temporary hold or "Hold" indi- cates hold mode.
12"Morn" "Day" "Eve" "Night" indicates period being programmed or current program in Run mode.
13"A" "P" indicates time as Morning (A) or Evening (P).
14"Mon - Sun" indicates day of week.
15"Month" "Year" "Date" indicates the Month Year or Date when setting time.
16"Call For Service" indicates a diagnostic fault in the heating/cooling system. It does not indicate a fault in the thermostat.
17"Change" indicates when batteries are low and should be replaced.
4